Discontinuous FRP-Confinement of Masonry Columns
Recent seismic events, all over the world, demonstrated that masonry constructions are prone to brittle collapses when shear or compression capacity is reached. It is clear that, in many real cases, masonry columns need to be strengthened for enhancing their load-carrying capacity and to develop a more ductile response. The Fiber Reinforced Polymers (FRPs) confinement of masonry columns is a well-known technique that may produce these advantages. Unfortunately, full-wrapping insulates the column from the environment; so interstitial humidity can easily occur and cause the acceleration of the masonry's decay. In order to prevent it, partial-confinement is commonly assessed instead of total-j…
Masonry columns confined with fabric reinforced cementitious matrix (FRCM) systems: A round robin test
Abstract The conservation and the preservation of existing masonry buildings, most of them recognized as cultural heritage, require retrofitting techniques that should reduce the invasiveness and assure reversibility and compatibility with the substrate. In this perspective, the strengthening system should be able to improve the bearing capacity of the structural member and, at the same time, to assure mechanical and material compatibility. The use of Fabric Reinforced Cementitious Matrix (FRCM) composites is now recognized to be suitable for these purposes. Indeed, the inorganic matrix has comparable properties with respect to the existing historical mortars while the fabric has relevant t…