0000000000648239

AUTHOR

L. Chabaane

showing 2 related works from this author

Immobilization of vegetable tannins on tannery chrome shavings and their use for the removal of hexavalent chromium from contaminated water

2011

Abstract Chestnut (C) and mimosa (M) tannins immobilized on chrome shavings (CS) as an adsorbent have been proposed to be an efficient and economical alternative in hexavalent chromium removal from aqueous solutions. The adsorption of hexavalent chromium onto chrome shavings-tannin (CS-T) adsorbents was performed using batch equilibrium technique at 25 ± 2 °C. The effect of pH is highly important especially in the case of high concentrations of hexavalent chromium. The maximum chromium uptake was obtained at pH 4. Two hours of contact time are enough to reach equilibrium. Sorption of chromium on CS-T was found to follow a pseudo-second order kinetic model (with correlation coefficients grea…

chemistry.chemical_classificationAqueous solutionChemistryGeneral Chemical EngineeringMetallurgyLangmuir adsorption modelchemistry.chemical_elementSorptionGeneral ChemistryIndustrial and Manufacturing Engineeringsymbols.namesakechemistry.chemical_compoundChromiumAdsorptionPolyphenolsymbolsEnvironmental ChemistryTanninHexavalent chromiumNuclear chemistryChemical Engineering Journal
researchProduct

Preliminary Results on the Use of Leather Chrome Shavings for Air Passive Sampling

2012

A new passive sampler based on low-density polyethylene (LDPE) layflat tube filled with chrome shavings from tannery waste residues was evaluated to determine volatile organic compounds (VOCs) in indoor and outdoor areas. VOCs were directly determined by head space-gas chromatography-mass spectrometry (HS-GC-MS) without any pretreatment of the sampler and avoiding the use of solvents. Limit of detection values ranging from 20 to 75 ng sampler−1and good repeatability values were obtained for VOCs under study with relative standard deviation values from 2.8 to 9.6% except for carbon disulfide for which it was 22.5%. The effect of the amount of chrome shavings per sampler was studied and resul…

Detection limitCarbon disulfideMaterials sciencelcsh:QD71-142Article SubjectGeneral Chemical EngineeringRelative standard deviationlcsh:Analytical chemistryRepeatabilityPolyethylenePulp and paper industrycomplex mixturesComputer Science ApplicationsAnalytical ChemistryLow-density polyethylenechemistry.chemical_compoundAdsorptionchemistryInstrumentationPassive samplingResearch ArticleJournal of Analytical Methods in Chemistry
researchProduct