0000000000650627

AUTHOR

Mario Lachat

showing 40 related works from this author

Mid-term results of zone 0 thoracic endovascular aneurysm repair after ascending aorta wrapping and supra-aortic debranching in high-risk patients

2017

Objectives Surgical repair of aneurysmal disease involving the ascending aorta, aortic arch and eventually the descending aorta is generally associated with significant morbidity and mortality. A less invasive approach with the ascending wrapping technique (WT), supra-aortic vessel debranching (SADB) and thoracic endovascular aneurysm repair (TEVAR) in zone 0 was developed to reduce the associated risk in these patients. Methods During a 10-year period, consecutive patients treated by the ascending WT, SADB and TEVAR in zone 0 were included. All patients were considered at high risk for conventional surgery. Measured outcomes included perioperative deaths and morbidity, maximal aortic trans…

MaleAortic archTime FactorsComputed Tomography AngiographyAneurysm; Arch; Ascending; Debranching; TEVAR; Wrapping; Surgery; Pulmonary and Respiratory Medicine; Cardiology and Cardiovascular Medicinemedicine.medical_treatmentWrapping030204 cardiovascular system & hematologyEndovascular aneurysm repairPostoperative Complications0302 clinical medicineRisk FactorsAscendingThoracic aorta030212 general & internal medicineAortaAged 80 and overTEVAR10042 Clinic for Diagnostic and Interventional RadiologyEndovascular ProceduresMiddle Aged2746 SurgeryItalyDescending aortaCardiologyFemaleCardiology and Cardiovascular MedicinePulmonary and Respiratory Medicinemedicine.medical_specialty10216 Institute of Anesthesiology610 Medicine & healthArch2705 Cardiology and Cardiovascular Medicine03 medical and health sciencesAneurysmBlood vessel prosthesismedicine.arteryInternal medicineAscending aortamedicineHumansAgedAortaAortic Aneurysm Thoracicbusiness.industryDebranchingmedicine.diseaseAneurysmBlood Vessel ProsthesisSurgery10020 Clinic for Cardiac Surgery2740 Pulmonary and Respiratory MedicineSurgeryMorbiditybusinessFollow-Up Studies
researchProduct

Popliteal Artery Aneurysm Repair in the Endovascular Era: Fourteen-Years Single Center Experience

2015

Abstract To compare outcomes of popliteal artery aneurysm (PAA) repair by endovascular treatment, great saphenous vein (GSV) bypass, and prosthetic bypass. Single center retrospective analysis of patients presenting PAA from 2000 to 2013. Patients were divided into endovascular treatment (group A); GSV bypass (group B); and prosthetic graft bypass (group C). Outcomes were technical success, perioperative mortality, and morbidity. Survival, primary and secondary patency, and freedom from reintervention rate were estimated. Differences in ankle-brachial index (ABI), in-hospital length of stay (InH-Los), red blood cell (RBC) transfusion, and limb loss were reported. Mean follow-up was 49 (medi…

Malemedicine.medical_specialtyTime Factors7100Observational Study610 Medicine & health2700 General MedicineSingle CenterSettore MED/22 - Chirurgia VascolareGroup Blaw.inventionBlood Vessel Prosthesis ImplantationAneurysmRandomized controlled triallawmedicine.arteryPopliteal Artery AneurysmmedicineHumansPopliteal ArteryAgedRetrospective Studiesbusiness.industryGreat saphenous veinEndovascular ProceduresAngiographyRetrospective cohort studyGeneral MedicinePerioperativeMiddle Agedmedicine.diseaseAneurysmPopliteal artery10020 Clinic for Cardiac SurgerySurgeryTreatment OutcomeSurgery Computer-AssistedAnesthesiaFluoroscopyFemaleStentsbusinessFollow-Up StudiesForecastingResearch Article
researchProduct

Mid- and Longer-term Follow up of Chimney and/or Periscope Grafts and Risk Factors for Failure

2016

Objective The aim was to report on chimney and periscope grafts (CPGs) and their mid- and longer-term outcomes when they are used to preserve reno-visceral artery (RVA) perfusion in endovascular repair of pararenal (PRAAs) or thoraco-abdominal aortic aneurysm (TAAAs). In addition, factors associated with CPG failure are presented. Limited data exist on the outcomes of CPGs, and mid- and long-term results are generally not reported. Methods This was a prospective study in a cohort of 100 patients with PRAA (69) or TAAA (31). A total of 224 (mean 2.24 per patient) RVAs were preserved with 136 (61%) chimney and 88 (39%) periscope grafts. CPGs were constructed mainly using self expandable stent…

MalePercutaneousmedicine.medical_treatment030204 cardiovascular system & hematologyEndovascular aneurysm repairSettore MED/22 - Chirurgia VascolareAortic aneurysm0302 clinical medicineRenal ArteryRisk FactorsOcclusion030212 general & internal medicineTreatment FailureProspective cohort studyAortaPararenal aortic aneurysm10042 Clinic for Diagnostic and Interventional RadiologyReno2746 SurgeryAortic AneurysmFemaleRadiologyCardiology and Cardiovascular Medicinemedicine.medical_specialty610 Medicine & health2705 Cardiology and Cardiovascular Medicine03 medical and health sciencesEndovascular aneurysm repairabdominal aortic aneurysmAneurysmChimney and periscope graftChimney and periscope graft; Complex aortic aneurysm; Endovascular aneurysm repair; Pararenal aortic aneurysm; Reno-visceral arteries; Thoraco-abdominal aortic aneurysm; Cardiology and Cardiovascular Medicine; SurgerymedicineHumansAgedRetrospective StudiesReno-visceral arterieThoraco-abdominal aortic aneurysmbusiness.industryComplex aortic aneurysmStentRetrospective cohort studyThoracomedicine.diseaseSurgeryvisceral arteriesSurgeryVascular GraftingbusinessFollow-Up Studies
researchProduct

Predilation technique with balloon angioplasty to facilitate percutaneous groin access of large size sheath through scar tissue

2017

Purpose Percutaneous remote access for endovascular aortic repair is an advantageous alternative to open access. Previous surgery in the femoral region and the presence of synthetic vascular grafts in the femoral/iliac arteries represent major limitations to percutaneous remote access. The aim of this study was to evaluate an original technique used for enabling percutaneous remote access for thoracic or abdominal endovascular aortic repair in patients with scar tissue and/or a vascular graft in the groin. Methods Twenty-five consecutive patients with a thoracic (11/25; 44%) or an aortic aneurysm (14/25; 66%) and with a synthetic vascular graft in the groin (16/25; 64%) or a redo groin acce…

MalePercutaneousmedicine.medical_treatment030204 cardiovascular system & hematologyBalloonEndovascular aneurysm repairSettore MED/22 - Chirurgia Vascolarecalcificationendovascular aneurysm repairAortic aneurysm0302 clinical medicinesheathprosthetic graftballoon angioplastyVascular closure device030212 general & internal medicineAged 80 and over10042 Clinic for Diagnostic and Interventional RadiologyVascular Access Deviceultrasonographyvascular closure deviceGeneral MedicineEquipment Design2746 SurgeryBlood Vessel Prosthesimedicine.anatomical_structureTreatment OutcomeFemaleRadiologyCardiology and Cardiovascular MedicineVascular Access DevicesHumanmedicine.medical_specialtycomplication610 Medicine & healthGroin2705 Cardiology and Cardiovascular MedicineAneurysm; balloon angioplasty; calcification; complications; endovascular aneurysm repair; infection; prosthetic graft; sheath; ultrasonography; vascular closure devices; Aged; Aged 80 and over; Angioplasty Balloon; Aortic Aneurysm Abdominal; Aortic Aneurysm Thoracic; Blood Vessel Prosthesis; Blood Vessel Prosthesis Implantation; Catheterization Peripheral; Cicatrix; Equipment Design; Female; Groin; Humans; Male; Treatment Outcome; Ultrasonography Interventional; Vascular Access Devices; Surgery; Radiology Nuclear Medicine and Imaging; Cardiology and Cardiovascular Medicine03 medical and health sciencesBlood Vessel Prosthesis ImplantationCicatrixBlood vessel prosthesisAngioplastyCatheterization Peripheralmedicine2741 Radiology Nuclear Medicine and ImagingHumansRadiology Nuclear Medicine and imagingUltrasonography InterventionalAgedGroinAortic Aneurysm Thoracicbusiness.industrymedicine.diseaseAneurysminfectionSurgery10020 Clinic for Cardiac SurgeryBlood Vessel ProsthesisSurgerybusinessAngioplasty BalloonAortic Aneurysm Abdominal
researchProduct

A clampless and sutureless aortic anastomosis technique using an endograft connector for aortoiliac occlusive disease in which the aorta cannot be cl…

2012

Bypass surgery in aortoiliac or aortofemoral occlusive disease can be technically demanding and hazardous due to huge calcifications and/or patient co-morbidities. We report about mid-term results of a telescoping sutureless aortic anastomosis technique using endografts as connectors to address such challenging situations. This is a single-center experience (2004–2011) in seven patients (63 ± 6 years) requiring aortoiliac (three) or aortofemoral (four) bypass surgery. In six cases, an aortic stent graft was telescoped into the infrarenal aorta and partly deployed within the aorta and partly outside the aorta. In the first case, a bifurcated stent graft was deployed and the iliac legs were …

Malemedicine.medical_specialtyPercutaneousTime Factorsmedicine.medical_treatmentAortic DiseasesAortoiliac occlusive diseaseArterial Occlusive Diseases610 Medicine & healthConstriction PathologicAnastomosisProsthesis DesignAortographyIliac Artery2705 Cardiology and Cardiovascular MedicineBlood Vessel Prosthesis ImplantationPostoperative Complicationsmedicine.arterymedicineHumans2741 Radiology Nuclear Medicine and ImagingRadiology Nuclear Medicine and imagingVascular CalcificationAgedAortabusiness.industry10042 Clinic for Diagnostic and Interventional RadiologyEndovascular ProceduresSuture TechniquesStentExternal iliac arteryGeneral MedicineMiddle Agedmedicine.diseaseConstrictionSurgeryBlood Vessel Prosthesis10020 Clinic for Cardiac Surgery2746 SurgeryStenosisTreatment OutcomeBypass surgerySurgeryFemaleStentsRadiologyCardiology and Cardiovascular MedicinebusinessTomography X-Ray Computed
researchProduct

The Gore Hybrid Vascular Graft in renovisceral debranching for complex aortic aneurysm repair.

2016

Objective This study reports our initial experience with the Gore Hybrid Vascular Graft (GHVG; W. L. Gore & Associates, Flagstaff, Ariz) for staged hybrid open renovisceral debranching and endovascular aneurysm repair in patients affected by thoracoabdominal aortic aneurysms and pararenal abdominal aortic aneurysms (PAAAs). Methods Between December 2012 and December 2013, we analyzed outcomes of 13 patients who underwent open surgical debranching of renovisceral vessels for thoracoabdominal aortic aneurysm and PAAAs. All patients were considered at high risk for conventional surgery. Inclusion criterion was treatment by open surgical debranching of at least one visceral artery (renal artery…

Malemedicine.medical_specialtyTime Factorsmedicine.medical_treatmentAortic RuptureKaplan-Meier Estimate030204 cardiovascular system & hematologyAnastomosisRevascularizationProsthesis DesignEndovascular aneurysm repairThoracic aortic aneurysmSettore MED/22 - Chirurgia VascolareDisease-Free Survival03 medical and health sciencesAortic aneurysmBlood Vessel Prosthesis Implantation0302 clinical medicineAneurysmPostoperative ComplicationsBlood vessel prosthesisRisk Factorsmedicine.arterymedicineHumans030212 general & internal medicineRenal arteryVascular PatencyAgedRetrospective StudiesAortic Aneurysm Thoracicbusiness.industryEndovascular ProceduresCardiology and Cardiovascular Medicine; SurgeryMiddle Agedmedicine.diseaseSurgeryBlood Vessel ProsthesisTreatment Outcomecardiovascular systemFeasibility StudiesSurgeryFemaleRadiologybusinessCardiology and Cardiovascular MedicineAortic Aneurysm AbdominalJournal of vascular surgery
researchProduct

Outpatient endovascular aortic aneurysm repair: Experience in 100 consecutive patients

2013

OBJECTIVES:: To present the safety, feasibility, costs, and patient satisfaction of outpatient endovascular aneurysm repair (EVAR). BACKGROUND:: Our experience in more than 1000 patients indicated that in technically uncomplicated EVAR procedures, the only need for hospitalization was for access vessel complications (bleeding or occlusion) requiring secondary procedures. These complications could always be identified within the first 3 hours after EVAR. METHODS:: Two-center retrospective analysis of prospectively gathered data on 100 consecutive elective outpatient EVAR cases (Outpt EVAR). Inclusion criteria for Outpt EVAR were as follows: asymptomatic clinical state, informed consent, trav…

Malemedicine.medical_specialtyPercutaneousmedicine.medical_treatment610 Medicine & healthEndovascular aneurysm repairSettore MED/22 - Chirurgia VascolareBlood Vessel Prosthesis ImplantationPostoperative ComplicationsPatient satisfactionAmbulatory CareHumansMedicineOutpatient clinicLocal anesthesiaambulant day endovascular aneurysm repair EVAR fast-track outpatient surgeryAgedRetrospective StudiesAged 80 and overbusiness.industry10042 Clinic for Diagnostic and Interventional RadiologyEndovascular ProceduresStentMiddle AgedVascular surgerymedicine.diseaseSurvival AnalysisSurgery10020 Clinic for Cardiac Surgery2746 SurgeryStenosisTreatment OutcomeCosts and Cost AnalysisFemaleSurgerybusinessAortic Aneurysm Abdominal
researchProduct

SS8. Chimney and Periscope Grafts: Mid-term Results in 77 Consecutive Patients with Complex Aortic Aneurysms

2012

Author Disclosures: N. D. Andersen: Nothing to disclose; G. Hughes: W.L. Gore and Associates,Research Grants W.L. Gore and Associates, Consulting fees or other remuneration (payment) W.L. Gore and Associates, Speaker’s bureauMedtronic Vascular, Consulting fees or other remuneration (payment) Medtronic Vascular, Speaker’s bureauVascutek Terumo, Consulting fees or other remuneration (payment) Vascutek Terumo, Speaker’s bureau; R. L. McCann: Nothing to disclose; A. A. Shah: Nothing to disclose; J. B. Williams: Nothing to disclose.

Nothingbusiness.industrymedia_common.quotation_subjectRemunerationMid term resultsMedicineSurgeryPaymentbusinessCardiology and Cardiovascular Medicinemedia_commonManagementJournal of Vascular Surgery
researchProduct

Acute aortic dissection

2011

An acute aortic syndrome with simultaneous presence of a penetrating aortic ulcer, an intramural haematoma, a thoracic aortic dissection and an abdominal aortic aneurysm rupture has not previously been reported. Herein, we describe our experience with a patient treated by endovascular means with an 8-year follow-up.

medicine.medical_specialtyTime FactorsAortic RuptureAortic Diseases610 Medicine & healthAortographySettore MED/22 - Chirurgia Vascolare2705 Cardiology and Cardiovascular MedicineBlood Vessel Prosthesis ImplantationInternal medicinemedicineHumanscardiovascular diseasesAortic ruptureUlcerAged 80 and overAcute aortic syndromeAortic dissectionHematomaAortic Aneurysm Thoracic10042 Clinic for Diagnostic and Interventional Radiologybusiness.industryEndovascular ProceduresSyndromeGeneral Medicinemedicine.diseaseAbdominal aortic aneurysm10020 Clinic for Cardiac SurgerySurgeryIntramural haematomaAortic DissectionTreatment Outcomeacute aortic dissection syndromeAcute Diseasecardiovascular systemCardiologyThoracic aortic dissectionFemaleTomography X-Ray ComputedCardiology and Cardiovascular MedicinebusinessAortic Aneurysm AbdominalJournal of Cardiovascular Medicine
researchProduct

Long-term results of simplified frozen elephant trunk technique in complicated acute type A aortic dissection: A case-control study.

2016

Aim To describe the long-term experience of a simplified frozen elephant trunk technique (sFETT) used in complicated acute type A aortic dissection (AAAD) treatment. Methods and results Between January 2001 and December 2012, 34 patients (mean age 59.9 ± 11.0 years) with complicated AAAD (DeBakey I) underwent an emergency surgery including sFETT. sFETT consisted in gluing the dissected aortic arch wall layers with gelatine-resorcinol adhesive and video-assisted antegrade open arch aortic stent-graft deployment in the arch or proximal descending aorta. In addition to sFETT, the aortic root was addressed with standard techniques. A 30-day mortality was 14.7% (five patients) due to bleeding (1…

MaleTime FactorsElephant trunksComputed Tomography AngiographyVideo-Assisted SurgeryKaplan-Meier Estimate030204 cardiovascular system & hematologyComplicated acute type A aortic dissectionSettore MED/22 - Chirurgia VascolareAortic aneurysm0302 clinical medicinePostoperative ComplicationsRisk Factorsfrozen elephant trunkComputed tomography angiographyAortic dissectionAged 80 and overmedicine.diagnostic_testMedicine (all)Endovascular ProceduresGeneral MedicineMiddle AgedAortic AneurysmTreatment OutcomeAcute typeAcute DiseaseFemaleStentsCardiology and Cardiovascular MedicineAdultReoperationmedicine.medical_specialtyAortographyProsthesis DesignAortography03 medical and health sciencesBlood Vessel Prosthesis ImplantationBlood vessel prosthesismedicineHumansRadiology Nuclear Medicine and imagingAgedRetrospective StudiesComplicated acute type A aortic dissection; frozen elephant trunk; Surgery; Medicine (all); Radiology Nuclear Medicine and Imaging; Cardiology and Cardiovascular Medicinebusiness.industryLong term resultsmedicine.diseaseSurgeryBlood Vessel ProsthesisAortic Dissection030228 respiratory systemSurgeryTissue AdhesivesEmergenciesbusinessVascular
researchProduct

Endoluminal Stent-Graft Relining of Visceral Artery Bypass Grafts to Treat Perigraft Seroma

2013

PURPOSE: To describe the endovascular treatment of intra-abdominal perigraft seromas associated with small-caliber expanded polytetrafluoroethylene (ePTFE) grafts. CASE REPORTS: Two patients who underwent hybrid repair of thoracoabdominal aortic aneurysms in which renovisceral bypass grafts were implanted presented with large, symptomatic perigraft seromas. The 5- to 8-mm-diameter ePTFE bypass grafts believed to be involved in the seromas were successfully relined with self-expanding Viabahn stent-grafts in percutaneous procedures. The patients' symptoms were relieved, and imaging follow-up (18 and 10 months, respectively) has shown near complete resorption of the seromas. CONCLUSION: It is…

Reoperationmedicine.medical_specialtyAortographyPercutaneous610 Medicine & healthProsthesis DesignAortography2705 Cardiology and Cardiovascular MedicineBlood Vessel Prosthesis ImplantationAortic aneurysmBlood vessel prosthesismedicinePerigraft seromaHumans2741 Radiology Nuclear Medicine and ImagingRadiology Nuclear Medicine and imagingPolytetrafluoroethyleneAortic Aneurysm Thoracicmedicine.diagnostic_testbusiness.industryEndovascular ProceduresMiddle Agedmedicine.diseaseBlood Vessel Prosthesis10020 Clinic for Cardiac Surgery2746 SurgerySurgerybody regionsVisceraSeromaTreatment Outcomesurgical procedures operativeBypass surgeryCardiothoracic surgerySeromaFemaleStentsSurgeryRadiologyTomography X-Ray ComputedCardiology and Cardiovascular MedicinebusinessJournal of Endovascular Therapy
researchProduct

Chimney and periscope grafts observed over 2 years after their use to revascularize 169 renovisceral branches in 77 patients with complex aortic aneu…

2013

^ ^Purpose: To evaluate the performance of periscope and/or chimney grafts (CPGs) in theendovascular treatment of pararenal or thoracoabdominal aneurysms using off-the-shelfdevices.Methods: Between February 2002 and August 2012, 77 consecutive patients (62 men; meanage 7369 years) suffering from pararenal aortic (n¼55), thoracoabdominal (n¼16), or arch tovisceral artery aneurysms (n¼6) were treated with aortic stent-graft implantation requiringchimney and/or periscope grafts to maintain side branch perfusion. CPGs were planned inadvance and were not used as bailout. A standardized follow-up protocol includingcomputed tomographic angiography, laboratory testing, and clinical examination wasp…

MaleAortic archmedicine.medical_specialtyTime FactorsEndoleakmedicine.medical_treatment610 Medicine & healthKaplan-Meier EstimateProsthesis DesignAortographyEndovascular aneurysm repair2705 Cardiology and Cardiovascular MedicineBlood Vessel Prosthesis ImplantationAortic aneurysmAneurysmBlood vessel prosthesismedicine.arterymedicineHumans2741 Radiology Nuclear Medicine and ImagingRadiology Nuclear Medicine and imagingRenal arteryVascular PatencyAgedRetrospective StudiesAged 80 and overAortic Aneurysm Thoracicmedicine.diagnostic_testbusiness.industry10042 Clinic for Diagnostic and Interventional RadiologyEndovascular ProceduresMiddle Agedmedicine.diseaseBlood Vessel ProsthesisSurgery10020 Clinic for Cardiac Surgery2746 SurgeryTreatment Outcomemedicine.anatomical_structureAngiographyFemaleStentsSurgeryRadiologyTomography X-Ray ComputedCardiology and Cardiovascular MedicinebusinessAortic Aneurysm AbdominalArtery
researchProduct

A New Off-Pump Hybrid Open and Endovascular Repair to Treat Ductus Botalli and Ascendens Aneurysms

2012

To report a combined ascending aorta and aortic arch hybrid repair, we performed off-pump with no aortic graft replacement. A 65-year-old man, developing progressive recurrent laryngeal nerve paralysis, underwent a computed tomography (CT) angiography detecting nonpatent residual ductus Botalli aneurysm and ascending aorta aneurysm. Due to severe multimorbidities, a less-invasive alternative was elaborated. In a first step, appropriate proximal landing zone for aortic stent grafting was achieved by ascending aorta diameter reduction, with epiaortic wrapping, and debranching the supra-aortic trunks. In the second step, endovascular stent grafts were deployed from proximal ascending aorta to…

MaleAortic archmedicine.medical_specialtyAortographymedicine.medical_treatment610 Medicine & healthAorta ThoracicAortographySettore MED/22 - Chirurgia Vascolare2705 Cardiology and Cardiovascular MedicineBlood Vessel Prosthesis ImplantationAortic aneurysmAneurysmmedicine.arteryAscending aortamedicineHumansThoracic aortacardiovascular diseasesDuctus Arteriosus PatentAgedCardiopulmonary Bypassmedicine.diagnostic_test10042 Clinic for Diagnostic and Interventional Radiologybusiness.industryEndovascular Proceduresaortic arch aortic operation carotid afteries endovascular procedures vascular diseaseStentGeneral Medicinemedicine.disease10020 Clinic for Cardiac Surgery2746 SurgeryAortic AneurysmSurgeryTreatment Outcomesurgical procedures operativeDescending aortacardiovascular systemSurgeryRadiologyTomography X-Ray ComputedCardiology and Cardiovascular MedicinebusinessVascular and Endovascular Surgery
researchProduct

Improved technique for sheath supported contralateral limb gate cannulation in endovascular abdominal aortic aneurysm repair

2019

Summary: Background: To present a technique of sheath supported contralateral limb gate (CLG) cannulation of modular bifurcated stent-graft in endovascular abdominal aortic repair. Materials and methods: After totally percutaneous bilateral femoral access, the 9F introducer sheath is exchanged to a 30 cm 12 fr introducer sheath over a stiff wire contralateral to the intended main stent-graft insertion side and advanced into the aorta below the lowest renal artery. Parallel to the stiff wire within the sheath an additional standard J-tip guidewire with a 5 fr Pigtail angiographic catheter is advanced to the level of the renal arteries. After main body deployment, the 12 fr introducer sheath…

Pigtailmedicine.medical_specialtyPercutaneouscannulation610 Medicine & healthSettore MED/22 - Chirurgia Vascolare2705 Cardiology and Cardiovascular MedicineBlood Vessel Prosthesis ImplantationRetrospective Studiemedicine.arterygatemedicineStentFluoroscopyHumansEVARREVARRenal arteryRetrospective StudiesAortamedicine.diagnostic_testbusiness.industry10042 Clinic for Diagnostic and Interventional RadiologyEndovascular Proceduresmedicine.diseaseAbdominal aortic aneurysmSurgeryBlood Vessel ProsthesisCatheterBlood Vessel ProsthesiTreatment Outcomecontralateral limbIntroducer sheathStentsCardiology and Cardiovascular MedicinebusinessHumanAortic Aneurysm Abdominal
researchProduct

Patient-Specific Rehearsal Feasibility Before Endovascular Repair of Ruptured Abdominal Aortic Aneurysm.

2019

Purpose: To evaluate the feasibility of a patient-specific rehearsal (PsR) before emergency endovascular aneurysm repairs (eEVAR) and its influence on the operation. Materials and Methods: From February 2016 to October 2016, 10 consecutive patients (mean age 75 +/- 7.4 years; 9 men) presenting with a ruptured abdominal aortic aneurysm (rAAA) suitable for standard EVAR were enrolled in the study. A 3-dimensional (3D) model of the abdominal aorta was generated on a virtual reality simulator based on the patient's computed tomography (CT) images. Following the patient-specific simulation setup, PsR was conducted during patient admission or in parallel with the preoperative eEVAR workup. Measur…

MaleModels AnatomicPatient-Specific Modelingmedicine.medical_specialtyTime Factorsmedicine.medical_treatmentAortic RuptureOperative TimeProsthesis DesignSettore MED/22 - Chirurgia VascolareEndovascular aneurysm repairendovascular aneurysm repairBlood Vessel Prosthesis Implantationabdominal aortic aneurysmAneurysmPostoperative ComplicationsRisk Factorsmedicine.arterymedicineHumansRadiology Nuclear Medicine and imagingpatient-specific rehearsalAgedAged 80 and overruptured aneurysmRuptured abdominal aortic aneurysmbusiness.industryAbdominal aortaEndovascular ProceduresModels CardiovascularPerioperativesimulationmedicine.diseaseAbdominal aortic aneurysmConfidence intervalBlood Vessel ProsthesisTreatment OutcomeSurgery Computer-AssistedPrinting Three-DimensionalFeasibility StudiesSurgeryFemaleStentsRadiologyCardiology and Cardiovascular MedicineComplicationbusinessAortic Aneurysm AbdominalJournal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
researchProduct

Identification of optimal device combinations for the chimney endovascular aneurysm repair technique within the PERICLES registry

2018

Abstract Objective The ideal stent combination for chimney endovascular aneurysm repair remains undetermined. Therefore, we sought to identify optimal aortic and chimney stent combinations that are associated with the best outcomes by analyzing the worldwide collected experience in the PERformance of chImney technique for the treatment of Complex aortic pathoLogiES (PERICLES) registry. Methods The PERICLES registry was reviewed for patients with pararenal aortic disease electively treated from 2008 to 2014. Eleven different aortic devices were identified with three distinct subgroups: group A (n = 224), nitinol/polyester; group B (n = 105), stainless steel/polyester; and group C (n = 69), n…

MaleRegistrieTime FactorsEndoleakmedicine.medical_treatmentComorbidity030204 cardiovascular system & hematology030230 surgeryEndovascular aneurysm repairSettore MED/22 - Chirurgia VascolareAortic aneurysm0302 clinical medicineRisk FactorsRetrospective StudieOcclusionOdds RatioStentRegistriesMultivariate AnalysiPolytetrafluoroethyleneAged 80 and overEndovascular ProceduresHazard ratioGraft Occlusion VascularEuropeBlood Vessel ProsthesiTreatment OutcomeCardiothoracic surgeryStentsFemaleCardiology and Cardiovascular MedicineSTENT GRAFT; CHIMENY GRAFT; CHIMNEY TECHINQUEHumanUnited Statemedicine.medical_specialtyHospitals Low-VolumeTime FactorPolyestersPolyesterProsthesis DesignDisease-Free Survival03 medical and health sciencesBlood Vessel Prosthesis ImplantationBlood vessel prosthesisAlloysmedicineHumansProportional Hazards ModelsRetrospective StudiesAgedEndovascular ProcedureAortic Aneurysm Thoracicbusiness.industryRisk FactorStentOdds ratiomedicine.diseaseStainless SteelUnited StatesBlood Vessel ProsthesisSurgeryMultivariate AnalysisAlloyProportional Hazards ModelSurgerybusinessHospitals High-VolumeAortic Aneurysm Abdominal
researchProduct

Less invasive (common) femoral artery aneurysm repair using endografts and limited dissection

2013

Objective We report our experience with the treatment of femoral artery aneurysms (FAAs) under local anaesthesia with limited dissection, using endografts to facilitate the proximal anastomosis and some distal anastomoses. Method Between January 2006 and December 2010, six males, mean age 72 years (range, 65–80 years) with FAAs were treated at the University Hospital of Zurich. All operations were performed under local anaesthesia with analgosedation, except for one performed under spinal anaesthesia. After limited dissection and puncture of the anterior wall of the FAA, a sheath and a self-expanding endograft were introduced over a guide wire and with fluoroscopy they were guided intralumi…

Malemedicine.medical_specialtyAnastomosismedicine.medical_treatmentEndograft610 Medicine & healthFemoral arteryDissection (medical)AnastomosisSettore MED/22 - Chirurgia Vascolare2705 Cardiology and Cardiovascular MedicineAneurysmmedicine.arteryDeep Femoral ArteryHumansMedicineAgedMedicine(all)Aged 80 and over10042 Clinic for Diagnostic and Interventional Radiologybusiness.industryEndovascular ProceduresBalloon catheterExternal iliac arteryStentmedicine.diseaseAneurysmBlood Vessel Prosthesis10020 Clinic for Cardiac Surgery2746 SurgerySurgeryFemoral ArteryCommon femoral arteryFemaleSurgeryRadiologyCardiology and Cardiovascular MedicinebusinessCommon femoral artery Aneurysm Endograft Anastomosis
researchProduct

Incidence and prognostic factors related to major adverse cerebrovascular events in patients with complex aortic diseases treated by the chimney tech…

2018

Abstract Objective Endovascular aneurysm repair (EVAR) with the chimney technique (ch-EVAR) has been used for the treatment of aortic aneurysms as an alternative approach to fenestrated endografting or open repair. Nonetheless, the need for an upper extremity arterial access may contribute to a higher risk for periprocedural cerebrovascular events. This study reports on the perioperative cerebral and major adverse cardiac and cerebrovascular events (MACCE) after ch-EVAR. Methods The PERICLES registry (PERformance of the chImney technique for the treatment of Complex aortic pathoLogiES) is an international, retrospective multicenter study evaluating the performance of ch-EVAR for the treatme…

RegistrieMaleTime Factorsmedicine.medical_treatment030204 cardiovascular system & hematologySettore MED/22 - Chirurgia VascolareEndovascular aneurysm repair0302 clinical medicineRetrospective StudieRisk FactorsCause of DeathCarotid artery diseaseOdds RatioRegistries030212 general & internal medicineMultivariate AnalysiStrokeCause of deathAged 80 and overIncidenceEndovascular ProceduresAtrial fibrillationchimney technique; stroke; aortic archMiddle AgedStrokeHeart DiseaseTreatment OutcomeIschemic Attack TransientCerebrovascular DisorderCardiologyFemaleCardiology and Cardiovascular MedicineHumanAdultmedicine.medical_specialtyAcute coronary syndromeLogistic ModelTime FactorHeart DiseasesOperative TimeAortic DiseasesBlood Vessel Prosthesis Implantation03 medical and health sciencesInternal medicinemedicineHumanscardiovascular diseasesAgedRetrospective StudiesEndovascular ProcedureChi-Square Distributionbusiness.industryRisk FactorOdds ratioPerioperativeAortic Diseasemedicine.diseaseSurgeryCerebrovascular DisordersLogistic ModelsMultivariate AnalysisSurgerybusiness
researchProduct

Simultaneous Hybrid Treatment of Multilevel Peripheral Arterial Disease in Patients with Chronic Limb-Threatening Ischemia

2021

Background: Hybrid treatments (HT) aim to reduce conventional open surgery invasiveness and address multilevel peripheral arterial disease (PAD). Herein, the simultaneous HT treatment in patients with chronic limb-threatening ischemia (CLTI) is reported. Methods: Retrospective analysis, for the period from May 2012 to April 2018, of patients presenting multilevel PAD with CLTI addressed with simultaneous HT. The outcomes of these interventions were measured the following metrics: early technical successes (within 30 days following treatment) and late technical successes (30 days or more following treatment) and included mortality, morbidity symptoms recurrence, and amputation. Survival and …

endovascular treatmentcritical limb ischemiamedicine.medical_specialtyArterial diseasemedicine.medical_treatmentIschemiaFemoral arterysimultaneous030204 cardiovascular system & hematologySettore MED/22 - Chirurgia VascolareArticle03 medical and health sciences0302 clinical medicineperipheral arterial diseasemedicine.arterymedicineIn patient030212 general & internal medicinebusiness.industryRGeneral MedicineCritical limb ischemiaPerioperativemedicine.diseaseSurgeryPeripheralAmputationMedicinehybrid treatmentmedicine.symptombusinessJournal of Clinical Medicine
researchProduct

A 12-Year Experience With Chimney and Periscope Grafts for Treatment of Type I Endoleaks.

2015

Purpose: To evaluate the midterm outcomes of chimney and/or periscope grafts (CPGs) in patients presenting type I endoleak after a previous endovascular aneurysm repair (EVAR). Methods: Between June 2002 and April 2014, 24 consecutive patients (mean age 73.9±9.2 years; 23 men) presenting a type I endoleak were addressed with CPGs to extend the proximal and/or distal landing zone and to maintain side branch perfusion. Indication for treatment was a type Ia endoleak in 23 (96%) patients and a type Ib endoleak in one. Median interval from the previous EVAR to endoleak treatment with CPGs was 52.2±48.9 months (range 0.2–179). All patients had proximal/distal landing zones precluding any standa…

Malemedicine.medical_specialtyEndoleakmedicine.medical_treatmentparallel graftTarget vesselmorbidityperiscope graftEndovascular aneurysm repairpararenal aortic aneurysmSettore MED/22 - Chirurgia Vascolarelaw.inventionendovascular aneurysm repairBlood Vessel Prosthesis Implantationabdominal aortic aneurysmlawRecurrencethoracoabdominal aortic aneurysmMedicineHumansRadiology Nuclear Medicine and imagingIn patientChimneyself-expanding covered stentVascular PatencyAgedabdominal aortic aneurysm; chimney graft; endoleak; endovascular aneurysm repair; morbidity; mortality; parallel graft; pararenal aortic aneurysm; patency; periscope graft; reintervention; self-expanding covered stent; stent-graft; target vessel; thoracoabdominal aortic aneurysmreinterventionstent-graftbusiness.industryEndovascular ProceduresChimney graftchimney graftmedicine.diseasemortalityAbdominal aortic aneurysmSurgeryBlood Vessel ProsthesisSurvival RateTreatment OutcomeSurgeryFemalePeriscopeCardiology and Cardiovascular Medicinebusinesspatencytarget vesselAortic Aneurysm AbdominalJournal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
researchProduct

Chronic Mesenteric Ischemia: Critical review and guidelines for management

2011

Background CMI is caused by chronic occlusive disease of mesenteric arteries. In such an uncommon disease, clear recommendations are strongly needed. Unfortunately, treatment options for symptomatic CMI are still controversial and no guidelines exist. Methods A systematic literature review of the last 25-years was conducted through MEDLINE, Embase, and Cochrane Review/Trials register to identify studies reporting on CMI treatment with more than 10 patients. Primary outcomes were perioperative mortality and morbidity rates. Secondary outcomes were survival rates, primary and secondary patency rates, vessels treated, CMI recurrence, follow-up (FU), technical success (TS), and in-hospital leng…

mesenteric chronic ischemia vascular surgeryPediatricsmedicine.medical_specialtyTime FactorsMEDLINE610 Medicine & healthDiseaseSettore MED/22 - Chirurgia Vascolare2705 Cardiology and Cardiovascular MedicineIschemiaRecurrenceRisk FactorsMesenteric Vascular OcclusionmedicineHumansVascular PatencyVascular DiseasesSurvival rateVascular PatencyChi-Square Distributionbusiness.industry10042 Clinic for Diagnostic and Interventional RadiologyPatient Selection10031 Clinic for AngiologyEndovascular ProceduresGeneral MedicinePerioperativeLength of Staymedicine.disease10020 Clinic for Cardiac Surgery2746 SurgeryTreatment OutcomeSystematic reviewMesenteric ischemiaMesenteric IschemiaPractice Guidelines as TopicSurgeryCardiology and Cardiovascular MedicinebusinessVascular Surgical ProceduresChi-squared distributionAlgorithms
researchProduct

Hypotensive Hemostasis in Patients Presenting with Ruptured Aortic Aneurysm

2017

Hypotensive hemostasis in aortic rupture has been showed to be feasible and advantageous, especially in trauma patients. To date, there are no randomized studies on hypotensive hemostasis in patients with ruptured abdominal aortic aneurysm (rAAA), but observational studies indicate similar advantages when hypotensive hemostasis is used for endovascular aneurysm repair (EVAR) as in trauma patients. Actually, in EVAR for rAAA, a target systolic blood pressure of 90 mmHg or even lower is considered safe in conscious patients. Fluids should be administrated judiciously with the sole aim of maintaining adequate cardiac output and tissue oxygenation, whereas vasoactive pressors or dilatators may …

Abdominal compartment syndromebusiness.industrymedicine.medical_treatmentHypotensive; Hemostasis; Ruptured; Aortic AneurysmHemodynamics030208 emergency & critical care medicineRuptured Aortic Aneurysm030204 cardiovascular system & hematologyHypotensiveHemostasimedicine.diseaseEndovascular aneurysm repairSettore MED/22 - Chirurgia VascolareAbdominal aortic aneurysmRupturedAortic Aneurysm03 medical and health sciences0302 clinical medicineBlood pressureAnesthesiaHemostasiscardiovascular systemmedicinebusinessAortic rupture
researchProduct

Endovascular Treatment of Spontaneous Internal Carotid Artery Dissection with Proximal Embolic Protection Device

2019

Background The aim of this study was to report the feasibility and outcomes with the endovascular treatment of spontaneous internal carotid artery dissections (ICADs) using a proximal embolic protection device (EPD). Methods This is a retrospective analysis of patients treated for spontaneous symptomatic ICAD using a proximal EPD from January 2017 to December 2018. Indication for treatment was the presence of neurologic symptoms. Early outcomes measured included technical success, perioperative mortality, and major cardiovascular or cerebrovascular complications. Late outcomes were recurrent neurologic symptoms, patency, and reinterventions. Results A total of 4 male patients with ICAD were…

Malemedicine.medical_specialtyICADAmaurosis FugaxCarotid Artery Internal Dissection030204 cardiovascular system & hematologySettore MED/22 - Chirurgia VascolareEmbolic Protection Devices030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineproximal embolic protection deviceRestenosisinternal carotid artery dissectionmedicine.arteryAphasiamedicineHumansCarotid StenosisStrokeRetrospective StudiesInternal carotid artery dissectioncarotid artery stentingbusiness.industryEndovascular ProceduresGeneral MedicineAmaurosis fugaxPerioperativeMiddle Agedmedicine.diseaseSurgeryStenosisTreatment OutcomeIschemic Attack TransientendovascularStentsSurgeryInternal carotid arterymedicine.symptomCardiology and Cardiovascular MedicinebusinessCarotid Artery Internal
researchProduct

Early outcomes with a single-sided access endovascular stent

2018

Abstract Objective The objective of this study was to report the 1-year follow-up study results of the new Horizon stent graft (Endospan, Herzliya, Israel) from two different prospective consecutive trials. The Horizon abdominal aortic aneurysm stent graft system is a 14F profile system requiring only a single access site. It consists of three modules, introduced separately: base limb (iliac to iliac limb); distal aortic limb; and proximal aortic limb with a bare suprarenal crown and active fixation. Methods Data from the first in man (FIM) clinical study with 10 patients enrolled and the pivotal study with 30 patients were analyzed. Outcomes measured were freedom from major adverse events …

Malemedicine.medical_specialtyTime FactorsTime Factormedicine.medical_treatment030204 cardiovascular system & hematologyProsthesis DesignAortographySettore MED/22 - Chirurgia Vascolare03 medical and health sciencesAortic aneurysmBlood Vessel Prosthesis ImplantationPostoperative Complications0302 clinical medicineAneurysmBlood vessel prosthesismedicineStentHumansAged; Aortic Aneurysm Abdominal; Aortography; Blood Vessel Prosthesis Implantation; Endovascular Procedures; Europe; Female; Humans; Male; Middle Aged; Postoperative Complications; Prospective Studies; Prosthesis Design; Time Factors; Tomography X-Ray Computed; Treatment Outcome; Blood Vessel Prosthesis; StentsProspective Studies030212 general & internal medicineStrokeAgedEndovascular Procedurebusiness.industryEndovascular ProceduresStentPerioperativeMiddle Agedmedicine.diseaseBlood Vessel ProsthesisSurgeryEuropeProspective StudieBlood Vessel ProsthesiTreatment OutcomeStentsFemaleSurgeryPostoperative ComplicationParaplegiabusinessTomography X-Ray ComputedCardiology and Cardiovascular MedicineAbdominal surgeryAortic Aneurysm AbdominalHuman
researchProduct

CT Angiography at 24 Months Demonstrates Durability of EVAR With the Use of Chimney Grafts for Pararenal Aortic Pathologies

2013

PURPOSE: To present the 24-month radiological follow-up data for patients with pararenal aortic pathologies treated with chimney and periscope grafts during endovascular repair. METHODS: Between January 2008 and December 2011, 124 high-risk patients with complex pararenal aortic pathologies were treated using the chimney technique at 2 European vascular and cardiovascular centers with advanced experience of the described technique. In particular, 50 patients were treated at Site 1 and 74 at Site 2. Forty (32.2%) patients (32 men; mean age 79.2±4.9 years) completed computed tomographic angiography follow-up at 24 months postoperatively. RESULTS: The overall technical success was 100%, and th…

Malemedicine.medical_specialtyTime Factorsmedicine.medical_treatmentAortic Diseases610 Medicine & healthEndovascular aneurysm repair2705 Cardiology and Cardiovascular MedicineAortic aneurysmAneurysmmedicine.arterymedicineHumans2741 Radiology Nuclear Medicine and ImagingRadiology Nuclear Medicine and imagingAorta AbdominalEmbolizationSuperior mesenteric arteryAgedendovascular aneurysm repair chimney graft periscope graft pararenal aortic pathologies aortic aneurysm para-anastomotic aneurysm ruptured aneurysm stent-graft balloon-expandable stent-graft computed tomographic angiography endoleak renal arteries superior mesenteric artery sac shrinkage sac expansionmedicine.diagnostic_test10042 Clinic for Diagnostic and Interventional Radiologybusiness.industryEndovascular ProceduresAngiographyPerioperativemedicine.diseaseBlood Vessel Prosthesis10020 Clinic for Cardiac Surgery2746 SurgerySurgeryCuffAngiographyFemaleStentsSurgeryRadiologyTomography X-Ray ComputedCardiology and Cardiovascular MedicinebusinessFollow-Up StudiesJournal of Endovascular Therapy
researchProduct

Chimney and periscope grafts to facilitate endovascular treatment of aortic transection in a patient with aberrant right subclavian artery

2014

Purpose: To report the use of parallel grafts to extend the proximal landing zone for stentgraft repair of aortic transection involving an aberrant right subclavian artery (ARSA). Case Report: A 28-year-old patient was referred for treatment of traumatic aortic transection with contained rupture at the level of an ARSA. Immediate thoracic endovascular aortic repair (TEVAR) was planned because of hemodynamic instability. To achieve rapid sealing and maintain perfusion to both subclavian arteries, a chimney stent to the left subclavian artery (LSA) and a periscope stent-graft to the ARSA were deployed successfully. After surgical repair of all fractures, the patient was discharged 1 month aft…

Adultmedicine.medical_specialtyTime FactorsAortic RuptureCardiovascular AbnormalitiesSubclavian ArteryHemodynamics610 Medicine & healthProsthesis DesignAortographySettore MED/22 - Chirurgia Vascolare2705 Cardiology and Cardiovascular MedicineBlood Vessel Prosthesis ImplantationBlood vessel prosthesisX ray computedmedicine.arterymedicineHumansThoracic aorta2741 Radiology Nuclear Medicine and ImagingRadiology Nuclear Medicine and imagingcardiovascular diseasesEndovascular treatmentAortabusiness.industryEndovascular ProceduresHemodynamicsAberrant right subclavian arteryVascular System InjuriesAneurysmBlood Vessel ProsthesisSurgery10020 Clinic for Cardiac Surgery2746 SurgeryTreatment Outcomesurgical procedures operativeRegional Blood FlowLanding zonecardiovascular systemStentsSurgeryAneurysm surgeryRadiologyDeglutition DisordersTomography X-Ray ComputedCardiology and Cardiovascular Medicinebusinessthoracic aorta aortic transection trauma thoracic endovascular aortic repair aberrant right subclavian artery left subclavian artery stent-graft parallel graft chimney graft periscope graft landing zone
researchProduct

Periscope endograft technique to revascularize the left subclavian artery during thoracic endovascular aortic repair.

2013

To present early and midterm results of the periscope endograft (PG) technique to maintain left subclavian artery (LSA) blood flow in thoracic endovascular aortic repairs (TEVAR) involving zone 3.From April 2010 to January 2013, 14 consecutive high-risk patients (11 men; mean age 70±8 years, range 56-87) underwent TEVAR with the PG technique for 10 thoracic aortic aneurysms (TAA), 2 traumatic aortic ruptures, and 2 aortic dissections without a suitable landing zone (2 cm distal to the LSA). Five procedures were performed emergently for rupture (3 TAAs and the 2 trauma cases). Two patients had a periscope deployed in an aberrant right subclavian artery. The periscope endografts were sized 1 …

Malemedicine.medical_specialtyTime FactorsAortic RuptureSubclavian ArteryAorta ThoracicDissection (medical)Kaplan-Meier EstimateProsthesis DesignThoracic aortic aneurysmAortographyAortic aneurysmBlood Vessel Prosthesis ImplantationAneurysmPostoperative ComplicationsBlood vessel prosthesismedicine.arterymedicineThoracic aortaHumansRadiology Nuclear Medicine and imagingcardiovascular diseasesVascular PatencyAgedAged 80 and overAortaAortic Aneurysm Thoracicbusiness.industryEndovascular ProceduresMiddle Agedmedicine.diseaseSurgeryBlood Vessel ProsthesisAortic Dissectionsurgical procedures operativeTreatment OutcomeCardiothoracic surgerycardiovascular systemSurgeryFemaleRadiologyCardiology and Cardiovascular MedicinebusinessTomography X-Ray ComputedJournal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
researchProduct

Treatment of isolated ascending aortic aneurysm by off-pump epiaortic wrapping is safe and durable.

2016

OBJECTIVES: Isolated ascending aortic aneurysm (iAA) is usually treated by open graft repair requiring sternotomy, cardiopulmonary bypass (CPB) and cardioplegia. This approach carries significant mortality in older patients or those presenting with comorbidities. We report an original series of patients presenting with iAA and treated with epiaortic wrapping by using a synthetic mesh. This less invasive aortic repair technique allows reducing the aortic diameter to a predefined value and is performed without CPB. METHODS: Data from patients presenting with an iAA and treated with the wrapping technique (WT) by polypropylene/polyester mesh from November 2006 to July 2015 were collected. The …

Aortic valveMaleTime Factors030204 cardiovascular system & hematologySettore MED/22 - Chirurgia Vascolarelaw.inventionAortic aneurysm0302 clinical medicinelawAorta10042 Clinic for Diagnostic and Interventional RadiologyMedicine (all)Middle Aged2746 Surgerymedicine.anatomical_structureTreatment OutcomeWrapping girdlingFemaleCardiology and Cardiovascular MedicineVascular Surgical ProceduresPulmonary and Respiratory Medicinemedicine.medical_specialtyOffOff-pump610 Medicine & healthProsthesis Design2705 Cardiology and Cardiovascular MedicineGraft repair03 medical and health sciencesAneurysmBlood vessel prosthesismedicine.arteryAscending aortamedicineCardiopulmonary bypassHumansAortic valve insufficiency; Ascending aorta; Graft repair; Mesh (polypropylene/polyester); Off-pump; Wrapping girdling; Surgery; Medicine (all); Pulmonary and Respiratory Medicine; Cardiology and Cardiovascular MedicineAgedRetrospective StudiesAortaAortic Aneurysm Thoracicbusiness.industryPerioperativemedicine.diseaseSternotomySurgeryBlood Vessel Prosthesis030228 respiratory systemAortic valve insufficiency2740 Pulmonary and Respiratory MedicinepumpSurgeryAscending aortaMesh (polypropylene/polyester)businessFollow-Up StudiesInteractive cardiovascular and thoracic surgery
researchProduct

Mid-term Results of Chimney and Periscope Grafts in Supra-aortic Branches in High Risk Patients

2017

Purpose Report mid-term outcomes of thoracic endovascular aneurysm repair (TEVAR) with chimney and periscope grafts (CPG) in supra-aortic branches (SAB). Methods Retrospective analysis, from October 2009 to May 2014, of patients with aneurysms requiring TEVAR with zone 0/1/2 proximal landing in association with at least one CPG in the SAB. All patients were considered at high risk for conventional surgery. Peri-operative mortality and morbidity, retrograde type A dissection, maximum aortic transverse diameter (TD) and its post-operative evolution, endoleak, survival, freedom from cardiovascular re-interventions, and CPG freedom from occlusion during the follow-up were analysed. Results Fort…

MaleTime FactorsEndoleakComputed Tomography Angiographymedicine.medical_treatmentMid term resultsKaplan-Meier Estimate030204 cardiovascular system & hematologySettore MED/22 - Chirurgia VascolareEndovascular aneurysm repairAortic aneurysmPostoperative Complications0302 clinical medicineRisk FactorsOcclusionMedicine030212 general & internal medicineAortic arch aneurysm; Chimney graft/technique; Endoleak; Endovascular aneurysm repair; Parallel graft; Periscope graft; Surgery; Cardiology and Cardiovascular MedicineAged 80 and overeducation.field_of_studyHigh risk patients10042 Clinic for Diagnostic and Interventional RadiologyEndovascular ProceduresMiddle Aged2746 SurgeryTreatment Outcomecardiovascular systemFemaleRadiologyCardiology and Cardiovascular MedicineAdultmedicine.medical_specialtyPopulation610 Medicine & healthProsthesis DesignAortographyRisk AssessmentDisease-Free Survival2705 Cardiology and Cardiovascular MedicineBlood Vessel Prosthesis ImplantationEndovascular aneurysm repair03 medical and health sciencesAneurysmmedicine.arteryHumanseducationAgedRetrospective StudiesAortaAortic Aneurysm ThoracicParallel graftAortic arch aneurysmbusiness.industryPatient SelectionChimney graft/techniquemedicine.diseaseBlood Vessel Prosthesis10020 Clinic for Cardiac SurgerySurgeryPeriscope graftSurgerybusinessEuropean Journal of Vascular and Endovascular Surgery
researchProduct

Multiple periscope and chimney grafts to treat ruptured thoracoabdominal and pararenal aortic aneurysms

2011

Purpose: To report midterm outcomes after urgent endovascular repair of ruptured pararenal or thoracoabdominal aortic aneurysms using multiple periscope and chimney grafts to preserve renovisceral branch perfusion and facilitate aneurysm exclusion. Methods: Nine consecutive men (mean age 72614 years, range 40–88) presenting with ruptured thoracoabdominal (n56), pararenal (n52), or infrarenal (n51) aortic aneurysm underwent urgent endovascular repair with at least 1 periscope graft delivered via a transfemoral access; chimney grafts were installed from an axillary access. In all, 17 periscope and 7 chimney grafts were used to reperfuse 11 renal and 13 visceral arteries in the 9 patients. The…

AdultMalemedicine.medical_specialtyTime Factorsmedicine.medical_treatmentAortic RuptureLess invasive610 Medicine & healthRuptured Aortic AneurysmProsthesis DesignEndovascular aneurysm repairSettore MED/22 - Chirurgia VascolareAortography2705 Cardiology and Cardiovascular Medicinelaw.inventionBlood Vessel Prosthesis ImplantationlawmedicineHumans2741 Radiology Nuclear Medicine and ImagingRadiology Nuclear Medicine and imagingChimneyAgedRetrospective Studiesendodebranching renovisceral arteries chimney graft periscope graft stentgraft endograft ruptured aortic aneurysm ruptured thoracoabdominal aortic aneurysm ruptured pararenal aortic aneurysm ruptured AAA endovascular aneurysm repairAged 80 and overAortic Aneurysm Thoracicbusiness.industry10042 Clinic for Diagnostic and Interventional RadiologyEndovascular ProceduresChimney graftBlood flowMiddle AgedSurgeryBlood Vessel Prosthesis10020 Clinic for Cardiac Surgery2746 SurgeryTreatment Outcomecardiovascular systemSurgeryFemaleStentsRadiologyPeriscopeCardiology and Cardiovascular MedicinebusinessTomography X-Ray ComputedAortic Aneurysm Abdominal
researchProduct

The use of Endurant stent-graft for abdominal aortic aneurysm: the story about extension of instruction for use with persistent good results of stent…

2012

The Endurant stent-graft (Medtronic, Inc., Minneapolis, MN, USA) is a latest generation device for the treatment of abdominal aortic aneurysm. The idea behind designing such a graft came from the intention to broad the instruction for use (IFU) and to enable it to treat more challenging anatomy including the 10mm neck lengths, and more severe suprarenal and infrarenal angulations. Endurant stent-graft has active fixation through suprarenal stent with anchoring pins to provide migration resistance, optimized heights of stents and spacing between them for improved flexibility and conformability, low-profile delivery system with hydrophilic coating and controlled simple deployment mechanism. S…

Clinical Trials as TopicEvidence-Based Medicine10042 Clinic for Diagnostic and Interventional RadiologyEndovascular Procedures610 Medicine & healthProsthesis DesignRisk Assessment2705 Cardiology and Cardiovascular Medicine10020 Clinic for Cardiac Surgery2746 SurgeryBlood Vessel ProsthesisBlood Vessel Prosthesis ImplantationTreatment OutcomeRisk FactorsHumansStentsClinical CompetenceRegistriesLearning Curvestents endovascular procedures aortic aneurysm abdominalAortic Aneurysm Abdominal
researchProduct

Endovascular Treatment of Spontaneous and Isolated Infrarenal Acute Aortic Syndrome with Unibody Aortic Stent-Grafts

2020

Abstract Introduction Spontaneous acute aortic syndrome (IAAS) is rarely localized in the infrarenal aorta. The endovascular approach is preferred over conventional open surgery with fewer complications. However, dedicated endovascular devices for IAAS treatment are unavailable. The aim was to report a large single-center experience using unibody stent-grafts to address IAAS. Methods From April 2016 to March 2019, a retrospective analysis of patients presenting spontaneous and isolated IAAS was performed. Patients addressed with the unibody stent-graft (AFX endovascular AAA system; Endologix Inc., Irvine, CA) were included in the study. Indications to IAAS treatment were persistent symptoms…

medicine.medical_specialtyOriginal Scientific Report030204 cardiovascular system & hematologyProsthesis DesignSettore MED/22 - Chirurgia VascolareInfrarenal acute aortic syndromeunibody stent-graftBlood Vessel Prosthesis Implantation03 medical and health sciencesAortic aneurysm0302 clinical medicineintramural hematoma.Blood vessel prosthesismedicine.arterymedicineHumansaortic dissection penetrating aortic ulcercardiovascular diseasesAorta Abdominal030212 general & internal medicineRetrospective StudiesAcute aortic syndromebusiness.industryEndovascular ProceduresAbdominal aortaVascular surgerymedicine.diseaseBlood Vessel ProsthesisSurgeryStenosissurgical procedures operativeTreatment OutcomeCardiothoracic surgeryendovascularStentsSurgerybusinessAortic Aneurysm AbdominalAbdominal surgeryWorld Journal of Surgery
researchProduct

Mortality rates and risk factors for emergent open repair of abdominal aortic aneurysms in the endovascular era

2018

The background of this paper is to report the mortality at 30 and 90 days and at mean follow-up after open abdominal aortic aneurysms (AAA) emergent repair and to identify predictive risk factors for 30- and 90-day mortality. Between 1997 and 2002, 104 patients underwent emergent AAA open surgery. Symptomatic and ruptured AAAs were observed, respectively, in 21 and 79% of cases. Mean patient age was 70 (SD 9.2) years. Mean aneurysm maximal diameter was 7.4 (SD 1.6) cm. Primary endpoints were 30- and 90-day mortality. Significant mortality-related risk factor identification was the secondary endpoint. Open repair trend and its related perioperative mortality with a per-year analysis and a co…

Malemedicine.medical_specialtyAbdominal compartment syndromemedicine.medical_treatment610 Medicine & healthSymptomatic030204 cardiovascular system & hematologySettore MED/22 - Chirurgia VascolareEndovascular aneurysm repairEndovascular aneurysm repair03 medical and health sciences0302 clinical medicineAneurysmRisk FactorsmedicineHumansMortalityRisk factorAgedRetrospective Studiesbusiness.industryOpen repairMortality rateEndovascular Procedures10060 Epidemiology Biostatistics and Prevention Institute (EBPI)PerioperativeMiddle Agedmedicine.diseaseSurvival AnalysisRupturedAbdominal aortic aneurysm10020 Clinic for Cardiac Surgery2746 SurgerySurgeryTreatment Outcome030220 oncology & carcinogenesisAbdominal aortic aneurysmFemaleVascular GraftingSurgeryEmergenciesbusinessAortic Aneurysm AbdominalFollow-Up StudiesAbdominal surgeryUpdates in Surgery
researchProduct

How to diagnose and treat abdominal compartment syndrome after endovascular and open repair of ruptured abdominal aortic aneurysms

2014

Intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) are frequently encountered in patients treated for ruptured abdominal aortic aneurysms (rAAA) and carry a high morbidity and mortality risk. Despite these facts, IAH/ACS are still overlooked by many physicians, timely diagnosis is missed and treatment often inadequate. All staff involved in the treatment of rAAA should be aware of the risk factors predicting IAH/ACS, the profound implications and derangements on all organ systems, the clinical presentation, the appropriate measurement of intra-abdominal pressure to detect IAH/ACS and the current treatment options for these detrimental syndromes. This comprehensive r…

10042 Clinic for Diagnostic and Interventional Radiology610 Medicine & healthIntra-abdominal hypertension - Aortic aneurysm abdominal - Endovascular proceduresSettore MED/22 - Chirurgia Vascolare2705 Cardiology and Cardiovascular Medicine2746 Surgery
researchProduct

RS12. Sustained Late Branch Patency and Low Incidence of Persistent Type Ia Endoleaks Following Snorkel/chimney EVAR Shown in the Updated PERICLES Re…

2016

medicine.medical_specialtybusiness.industryIncidence (epidemiology)030204 cardiovascular system & hematologySettore MED/22 - Chirurgia VascolareSurgery03 medical and health sciences0302 clinical medicineEndoleak; snorkel; chimney; PERICLEMedicineSurgeryChimney030212 general & internal medicineCardiology and Cardiovascular Medicinebusiness
researchProduct

Use of covered chimney stents for pararenal aortic pathologies is safe and feasible with excellent patency and low incidence of endoleaks.

2012

Background To present the clinical experience of consecutive series with use of balloon-expandable and self-expanding chimney endografts (balloon-expandable covered stent group [BECS] vs self-expanding covered stent group [SECS]) in the endovascular treatment of challenging aortic pathologies requiring renal and/or visceral revascularization. Methods Between January 2009 and May 2011, data for 37 high-risk patients from one center and 35 patients from another institution, with pararenal aortic pathologies treated by the chimney endovascular technique, were prospectively collected. The chimney-graft technique is based on the deployment of a covered or bare-metal stent parallel to the aortic …

Malemedicine.medical_specialtyTime FactorsEndoleakmedicine.medical_treatmentEVAR aneurysm chimney periscopesAortic Diseases610 Medicine & healthKaplan-Meier EstimateRevascularizationBalloonProsthesis DesignSettore MED/22 - Chirurgia VascolareAortographyRisk Assessment2705 Cardiology and Cardiovascular MedicineBlood Vessel Prosthesis ImplantationPredictive Value of TestsRisk FactorsAngioplastyGermanymedicineHumansVascular PatencyComputed tomography angiographyAgedRetrospective StudiesAged 80 and overmedicine.diagnostic_testbusiness.industryStentPerioperativemedicine.disease10020 Clinic for Cardiac Surgery2746 SurgerySurgeryBlood Vessel ProsthesisStenosisTreatment OutcomeCuffSurgeryFemaleStentsRadiologyCardiology and Cardiovascular MedicinebusinessTomography X-Ray ComputedAngioplasty BalloonSwitzerlandJournal of vascular surgery
researchProduct

Branch ligatures and blood aspiration for post-traumatic superficial temporal artery pseudoaneurysm: surgical technique

2014

The aim of this study is to report a new minimally invasive technique of superficial temporal artery (STA) pseudoaneurysm treatment. Several surgical options have been employed to treat STA pseudoaneurysms. To address this rare condition, the employed techniques are ligation and excision of the aneurysm, endovascular coil embolization or percutaneous ultrasound-guided thrombin injection. Between techniques no significant differences are reported in terms of outcomes. The decision to adopt a technique depends on STA pseudoaneurysm morphology and surgeon preference. In the present report, STA pseudoaneurysm afferent and efferent branches were identified by ultrasound in a 92-year-old female. …

Pulmonary and Respiratory Medicinemedicine.medical_specialtyPercutaneousDecompression610 Medicine & healthSettore MED/22 - Chirurgia Vascolaredigestive system2705 Cardiology and Cardiovascular MedicinePseudoaneurysmAneurysmmedicine.arterymedicineCraniocerebral TraumaHumansMinimally Invasive Surgical Procedurescardiovascular diseasesLigationAged 80 and over10042 Clinic for Diagnostic and Interventional Radiologybusiness.industryTemporal Artery Pseudoaneurysm Post-traumaticGeneral Medicinemedicine.diseaseSuperficial temporal artery10020 Clinic for Cardiac Surgery2746 SurgerySurgeryCardiac surgeryTemporal Arteriesmedicine.anatomical_structure2740 Pulmonary and Respiratory MedicineCardiothoracic surgerycardiovascular systemSurgeryFemaleRadiologyCardiology and Cardiovascular MedicinebusinessAneurysm FalseArtery
researchProduct

Early endovascular aneurysm repair after percutaneous coronary interventions

2015

Objective The objective of this study was to report long-term results of early endovascular aortic aneurysm repair after percutaneous coronary intervention (PCI). Methods This was a retrospective analysis of all patients presenting with abdominal aortic aneurysm and coronary artery disease treated during the same hospitalization by endovascular aortic aneurysm repair performed soon after PCI. Primary outcomes were perioperative mortality, perioperative complications, survival after treatment, and freedom from reintervention. Results A total of 20 patients were included, and all completed both procedures. No deaths or abdominal aortic aneurysm ruptures occurred between the PCI and the aortic…

Malemedicine.medical_treatmentCoronary DiseaseComorbidityEndovascular aneurysm repairSettore MED/22 - Chirurgia VascolareCoronary artery diseaseAortic aneurysmPostoperative ComplicationsRisk FactorsRetrospective StudieCause of DeathMyocardial infarctionHospital MortalityAged; Aged 80 and over; Aortic Aneurysm Abdominal; Cause of Death; Combined Modality Therapy; Comorbidity; Coronary Disease; Follow-Up Studies; Hospital Mortality; Humans; Italy; Male; Middle Aged; Postoperative Complications; Reoperation; Retrospective Studies; Risk Factors; Survival Rate; Early Medical Intervention; Percutaneous Coronary Intervention; Cardiology and Cardiovascular Medicine; Surgery; Medicine (all)Aged 80 and overMedicine (all)Middle AgedCombined Modality TherapyAbdominal aortic aneurysm2746 SurgerySurvival RateItalycardiovascular systemCardiologyCardiology and Cardiovascular MedicineHumanReoperationmedicine.medical_specialty10216 Institute of Anesthesiology610 Medicine & health2705 Cardiology and Cardiovascular MedicineFollow-Up StudiePercutaneous Coronary InterventionInternal medicineEarly Medical InterventionmedicineHumanscardiovascular diseasesRetrospective StudiesAgedbusiness.industryRisk FactorPercutaneous coronary interventionPerioperativemedicine.disease10020 Clinic for Cardiac SurgerySurgeryConventional PCISurgeryPostoperative ComplicationbusinessFollow-Up StudiesAortic Aneurysm Abdominal
researchProduct

Single-centre experience and preliminary Results of intravascular ultrasound in endovascular aneurysm repair

2019

Background Intravascular ultrasound (IVUS) has been introduced as diagnostic adjunct to provide new insights into the diagnosis and therapy of vascular disease. Herein, we compared the outcomes of conventional endovascular aneurysm repair (EVAR) and EVAR with IVUS in patients presenting with infrarenal abdominal aortic aneurysm using a propensity-matched cohort. Methods From May 2013 to August 2017, 221 patients were retrospectively analyzed. Of that, 122 patients were eligible for inclusion and underwent propensity score matching. Perioperative mortality and morbidity, renal function impairment, endoleak incidence, mean contrast medium usage, operative time, radiation exposure (including f…

MaleTime Factorsmedicine.medical_treatmentContrast MediaPredictive Value of TestEndovascular aneurysm repairSettore MED/22 - Chirurgia VascolareAortic aneurysmRetrospective StudieRisk FactorsIntravascular ultrasoundFluoroscopyAged 80 and overmedicine.diagnostic_testEndovascular ProceduresGeneral MedicineMiddle AgedRadiation ExposureAbdominal aortic aneurysm2746 SurgeryTreatment OutcomeItalyFemaleRadiologyCardiology and Cardiovascular Medicinerenal function impairmentHumanPreliminary Datamedicine.medical_specialtyTime Factor610 Medicine & healthRadiation DosageAortography2705 Cardiology and Cardiovascular Medicineintravascular ultrasoundBlood Vessel Prosthesis ImplantationEndovascular aneurysm repaircontrast mediumPredictive Value of Testsmedicinefluoroscopy timeHumansUltrasonography InterventionalAgedRetrospective StudiesEndovascular Procedurebusiness.industryRisk FactorAngiography Digital SubtractionPerioperativeDigital subtraction angiographymedicine.disease10020 Clinic for Cardiac SurgeryAngiographySurgerybusinessAortic Aneurysm Abdominal
researchProduct

Classification of Chimney EVAR-Related Endoleaks: Insights from the PERICLES Registry

2017

Juxtarenal aortic aneurysms (JAAs) pose significant challenges for endovascular aneurysm repair (EVAR). A short or absent infrarenal neck typically excludes standard EVAR as a viable or reasonable treatment option. In this context, the use of chimney grafts (chEVAR) is gaining in popularity and applicability. These grafts are designed to course in the aortic lumen outside the main stent-graft to maintain normal perfusion to the involved target branches. As such, they may represent a promising and less resource-intensive option for management of JAAs. However, this technical strategy is not without challenges of its own, particularly the inevitable creation of “gutters” that result from the …

medicine.medical_specialtyRadiology Nuclear Medicine and Imagingabdominal aortic aneurysm; chimney graft; chimney technique; endograft; endoleak; stent-graftendoleak610 Medicine & health030204 cardiovascular system & hematologySettore MED/22 - Chirurgia Vascolare2705 Cardiology and Cardiovascular Medicine03 medical and health sciences0302 clinical medicineabdominal aortic aneurysmchimney techniqueNuclear Medicine and Imagingmedicine2741 Radiology Nuclear Medicine and ImagingChimney030212 general & internal medicinestent-graftbusiness.industryChimney graftchimney graftendograftmedicine.diseaseAbdominal aortic aneurysmSurgery10020 Clinic for Cardiac Surgery2746 SurgerygraftSurgerystentRadiologybusinessCardiology and Cardiovascular Medicineabdominal aortic aneurysm; chimney graft; chimney technique; endograft; endoleak; stent-graft; Radiology Nuclear Medicine and Imaging; Cardiology and Cardiovascular Medicine
researchProduct