0000000000660972

AUTHOR

Cristian Bucurenciu

showing 2 related works from this author

Geometric Analysis of Type B Aortic Dissections Shows Aortic Remodeling After Intervention Using Multilayer Stents

2020

Recently, multilayer stents for type B aortic dissections (TBAD) have been proposed to decrease false lumen flow, increase and streamline true lumen flow, and retain branch vessel patency. We aimed to provide a protocol with standardized techniques to investigate aortic remodeling of TBAD by multilayer flow modulators (MFM) in static geometric and hemodynamic analyses. Combining existing literature and new insights, a standardized protocol was designed. Using pre- and postoperative CT scans, geometric models were constructed, lumen dimensions were calculated, computational fluid dynamics (CFD) models were composed, and velocity and pressures were calculated. Sixteen TBAD cases treated with …

Materials scienceGeometric analysisHemodynamics3d modelcomputational fluid dynamics030204 cardiovascular system & hematologylcsh:TechnologyArticle03 medical and health sciences0302 clinical medicinemedicineMedical imagingGeneral Materials Scienceaortic dissectionlcsh:Microscopylcsh:QC120-168.85Aortic dissectionlcsh:QH201-278.5multilayer flow modulatorlcsh:Tmedicine.diseaseaortic remodelinggeometric analysisLumen DiameterFlow velocitylcsh:TA1-2040lcsh:Descriptive and experimental mechanicslcsh:Electrical engineering. Electronics. Nuclear engineeringlcsh:Engineering (General). Civil engineering (General)lcsh:TK1-9971030217 neurology & neurosurgeryBiomedical engineeringLumen (unit)Materials
researchProduct

Study of aortic dissections treatment. Segmentation, simulation and valiadation of surgical results

2019

Nowadays, Computational Fluid Dynamics (CFD) it’s seen as the new trend in the management of aortic pathologies. Together with visualization capabilities of cardiovascular magnetic resonance (CMR) and computed tomography (CT) imaging, real time segmentation (volumetric) models further used as meshes in Computational Fluid Dynamic supply to the clinicians an innovative and extensive decision-making system. In the present paper, we identified and analysed the clinical indicators (lumens diameters, fenestrated area and blood volume) monitored by clinicians to evaluate the patient’ condition before and after the intervention. In order to achieve the targeted aims, we used CT scans as input data…

Surgical results03 medical and health sciencesmedicine.medical_specialty0302 clinical medicine030228 respiratory systembusiness.industrylcsh:TA1-2040medicineSegmentationRadiology030204 cardiovascular system & hematologybusinesslcsh:Engineering (General). Civil engineering (General)MATEC Web of Conferences
researchProduct