0000000000661283
AUTHOR
Ruth Kirschner-hermanns
The TiLOOP® Male Sling: Did We Forejudge.
<b><i>Introduction:</i></b> To evaluate the safety and efficacy of the TiLOOP® male sling (pfm medical, Cologne, Germany) used in the treatment for male stress urinary incontinence (SUI). <b><i>Material and Methods:</i></b> We retrospectively evaluated a total of 34 patients with a TiLOOP® male sling. Perioperative complication rates were assessed and validated questionnaires were prospectively evaluated to assess quality of life and satisfaction rate. Outcome and complication rates were analysed by using descriptive statistics. Correlation of continence outcome and risk factors was performed with the chi-square test. A <i>p</i> va…
High/low-volume center experience predicts outcome of AMS 800 in male stress incontinence: Results of a large middle European multicenter case series.
AIM To analyze the influence of implantation volume of artificial sphincters (AMS 800) on outcome in a large central European multicenter cohort study. METHODS As part of the DOMINO (Debates on Male Incontinence) project, the surgical procedures and outcomes were retrospectively analyzed in a total of 473 patients who received an artificial sphincter (AMS 800) between 2010 and 2012. Clinics that implanted at least 10 AMS 800 per year were defined as high-volume centers. RESULTS Sixteen centers had a mean rate of 9.54 AMS 800/y of which five clinics were identified as high-volume centers. They implanted significantly more double cuffs (55% vs 12.1%; P < .001), used the perineal approach sign…
Artificial Urinary Sphincter Cuff Size Predicts Outcome in Male Patients Treated for Stress Incontinence: Results of a Large Central European Multicenter Cohort Study
Purpose The aim was to study the correlation between cuff size and outcome after implantation of an AMS 800 artificial urinary sphincter. Methods A total of 473 male patients with an AMS 800 sphincter implanted between 2012 and 2014 were analyzed in a retrospective multicenter cohort study performed as part of the Central European Debates on Male Incontinence (DOMINO) Project. Results Single cuffs were implanted in 54.5% and double cuffs in 45.5% of the patients. The cuffs used had a median circumference of 4.5 cm. Within a median follow of 18 months, urethral erosion occurred in 12.8% of the cases and was associated significantly more often with small cuff sizes (P<0.001). Multivariate ana…
Fixed or adjustable sling in the treatment of male stress urinary incontinence: results from a large cohort study
BACKGROUND: Fixed and adjustable male slings for the treatment of male urinary stress incontinence became increasingly popular during the last decade. Although fixed slings are recommended for the treatment of mild to moderate stress urinary incontinence, there is still a lack of evidence regarding the precise indication for an adjustable male sling. Furthermore, there is still no evidence that one type of male sling is superior to another. However, both, adjustable and fixed slings, are commonly utilized in daily clinical practice. This current investigation aims to evaluate the differences between fixed and adjustable male slings regarding indications, complication rates and functional ou…