0000000000667845

AUTHOR

Sabine Maehrlein

showing 3 related works from this author

The pyrrole moiety as a template for COX-1/COX-2 inhibitors

2000

Aroyl- and thiophene-substituted pyrrole derivatives have been synthesized as a new class of COX-1/COX-2 inhibitors. The inhibition of COX-1 was evaluated in a biological system using bovine PMNLs as the enzyme source, whereas LPS-stimulated human monocytes served as the enzyme source for inducible COX-2. The determination of the concentration of arachidonic acid metabolites was performed by HPLC for COX-1 and RIA for COX-2. Variation of the substitution pattern led to a series of active compounds which showed inhibition for COX-1 and COX-2. Structural requirements for the development of COX-1/COX-2 inhibitors are discussed.

DiclofenacNeutrophilsStereochemistryIndomethacinThiophenesHigh-performance liquid chromatographyMonocytesPyrrole derivativeschemistry.chemical_compoundDrug DiscoveryAnimalsHumansStructure–activity relationshipMoietyCyclooxygenase InhibitorsPyrrolesSulfonesPyrrolePharmacologychemistry.chemical_classificationArachidonic AcidCyclooxygenase 2 InhibitorsMolecular StructureAnti-Inflammatory Agents Non-SteroidalOrganic ChemistryMembrane ProteinsGeneral MedicineIsoenzymesEnzymechemistryMembrane proteinBiochemistryCyclooxygenase 2Prostaglandin-Endoperoxide SynthasesCyclooxygenase 1Leukocytes MononuclearCattleArachidonic acidEuropean Journal of Medicinal Chemistry
researchProduct

Simultaneous determination of olanzapine, clozapine and demethylated metabolites in serum by on-line column-switching high-performance liquid chromat…

2001

An automated method for simultaneous routine quantification of the antipsychotic drugs clozapine, olanzapine and their demethylated metabolites is described. The method included adsorption on a cyanopropyl (CPS) coated clean-up column (10 microm; 10 x 2.0 mm I.D.), washing off interfering serum constituents to waste, and separation on C18 ODS Hypersil reversed phase material (5 microm; 250 x 4.6 mm I.D.) using acetonitrile-water-tetramethylethylenediamine (37:62.6:0.4, v/v/v) adjusted to pH 6.5 with concentrated acetic acid. UV-detection was performed at 254 nm. The limit of quantification was 10-20 ng/ml. Relative day to day standard variations ranged between 4.5 and 13.5%. The method is s…

Detection limitChromatographyChemistryMetaboliteReproducibility of ResultsGeneral ChemistryPirenzepineHigh-performance liquid chromatographySensitivity and SpecificityAcetic acidchemistry.chemical_compoundBenzodiazepinesAdsorptionPharmacokineticsOlanzapinemedicineHumansSpectrophotometry UltravioletQuantitative analysis (chemistry)ClozapineClozapineChromatography High Pressure Liquidmedicine.drugAntipsychotic AgentsJournal of chromatography. B, Biomedical sciences and applications
researchProduct

ChemInform Abstract: The Pyrrole Moiety as a Template for COX-1/COX-2 Inhibitors.

2000

chemistry.chemical_compoundChemistryStereochemistryCox 1 cox 2MoietyGeneral MedicinePyrrole derivativesPyrroleChemInform
researchProduct