Subjective Satisfaction in Long-term Orthokeratology Patients

2013

Purpose: To AU3 evaluate the subjective satisfaction in visual stability, night vision complains, and light distortion phenomena, and also the number of hours and days per week of lens wear, in patients with myopia undergoing orthokeratology (OK) treatment for at least 1 year. Methods: A visual analog scale (VAS) questionnaire containing 18 items was administered to 44 patients, 29 women and 15 men (mean age, 24.39 6 9.11 years), with a baseline spherical equivalent refractive error of 22.40 6 0.94 diopters and astigmatism up to 20.5 diopters. Average treatment period by the time of data collection was 19 6 7 months. Patients rated their satisfaction with the correction, with complaints of …

AdultMaleLight distortionVisual acuityAdolescentvisual acuitygenetic structuresmedicine.medical_treatmentSubjective satisfactionRefraction OcularYoung Adult03 medical and health sciences0302 clinical medicineOpticsSurveys and QuestionnairesNight visionHumansMedicineIn patientChildPain Measurement030304 developmental biologyAU6 visual acuity0303 health sciencesScience & Technologybusiness.industryOrthokeratologyMiddle AgedRefractive Errorseye diseasesCorneal refractive therapy3. Good healthTerm (time)OphthalmologyPatient Satisfaction030221 ophthalmology & optometryPatient ComplianceOptometryFemalemedicine.symptomOvernight orthokeratologybusinessOrthokeratologic ProceduresEye & Contact Lens: Science & Clinical Practice
researchProduct

Comparison of Macular Thickness in Patients with Keratoconus and Control Subjects Using the Cirrus HD-OCT

2014

Purpose.The aim of the present study was to compare macular thickness in patients with keratoconus (KC) with macular thickness in healthy subjects.Subjects and Methods.Twenty-six patients with KC and 52 control subjects were included. The macular structure was evaluated using a Zeiss Cirrus HD-OCT. The scan pattern used was 512 × 128, which covers an area of approximately 6 × 6 mm of the retina. The cube volume was assessed as well as macular thickness in each of the 9 sectors defined by the software.Results.The mean signal strength was significantly lower in the KC group (mean 8.4, range 6–10) compared with the control group (mean 9.7, range 7–10),P<0.0001(unpairedt-test). There were no…

AdultMaleKeratoconusmedicine.medical_specialtygenetic structuresArticle Subjectlcsh:MedicineKeratoconusAge and sexGeneral Biochemistry Genetics and Molecular BiologySignal strengthOphthalmologyHumansMedicineMacula LuteaIn patientGeneral Immunology and Microbiologybusiness.industrylcsh:RHealthy subjectsGeneral MedicineMiddle AgedControl subjectsmedicine.diseaseeye diseasesCase-Control StudiesOptometryFemaleCirrussense organsbusinessTomography Optical CoherenceResearch ArticleBioMed Research International
researchProduct

Evaluation of the anterior chamber angle in keratoconus and normal subjects.

2015

To evaluate the anterior chamber angle in keratoconus eyes by use of the Visante™ OCT and Orbscan™ II.Anterior chamber angle was measured with the Visante™ OCT and Orbscan™ II in 52 subjects, 26 KC subjects and 26 age and control subjects.When comparing the nasal and temporal angles obtained with the two techniques no correlation was found (R(2) always below 0.01) in either the control subjects or in the KC subjects. Despite this, there was an overall statistically significant difference in mean anterior chamber angles (p0.001) between Visante™ OCT and Orbscan™ II. There was no statistical difference (p0.05) between nasal and temporal anterior chamber angles when comparing controls and KC s…

AdultMaleKeratoconusmedicine.medical_specialtyKeratoconusSensitivity and SpecificityAnterior chamber angleAnterior Eye SegmentReference ValuesOphthalmologymedicineHumansOrbscan iiSlit Lampbusiness.industrySignificant differenceCorneal TopographyReproducibility of ResultsGeneral Medicinemedicine.diseaseControl subjectsOphthalmologyOptometryFemalebusinessTomography Optical CoherenceOptometryContact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

Power Profiles and In Vitro Optical Quality of Scleral Contact Lenses: Effect of the Aperture and Power

2017

To assess the power profile and in vitro optical quality of scleral contact lenses with different powers as a function of the optical aperture. The mini and semiscleral contact lenses (Procornea) were measured for five powers per design. The NIMO TR-1504 (Lambda-X) was used to assess the power profile and Zernike coefficients of each contact lens. Ten measurements per lens were taken at 3- and 6-mm apertures. Furthermore, the optical quality of each lens was described in Zernike coefficients, modulation transfer function, and point spread function (PSF). A convolution of each lens PSF with an eye-chart image was also computed. The optical power fluctuated less than 0.5 diopters (D) along th…

Optics and PhotonicsMaterials scienceContact LensesAperturePhysics::OpticsOptical powerAstrophysics::Cosmology and Extragalactic AstrophysicsIn Vitro TechniquesRefraction Ocularlaw.invention03 medical and health sciences0302 clinical medicineOpticslawOptical transfer functionHumansDioptreAnalysis of Variancebusiness.industryLens speedEquipment DesignLens (optics)Contact lensOphthalmology030221 ophthalmology & optometryGradient-index opticsbusiness030217 neurology & neurosurgeryEye & Contact Lens: Science & Clinical Practice
researchProduct

The posterior chamber phakic refractive lens (PRL): a review

2012

Implantation of phakic intraocular lenses (pIOLs) is a reversible refractive procedure, preserving the patient’s accommodative function with minimal induction of higher order aberrations compared with corneal photoablative procedures. Despite this, as an intraocular procedure, it has potential risks such as cataracts, chronic uveitis, pupil ovalization, corneal endothelial cell loss, pigmentary dispersion syndrome, pupillary block glaucoma, astigmatism, or endophthalmitis. Currently, only two models of posterior chamber pIOLs are commercially available, the implantable collammer lens (STAAR Surgical Co.) and the phakic refractive lens (PRL; Zeiss Meditec). The number of published reports on…

Phakic Intraocular Lensesmedicine.medical_specialtygenetic structuresmedicine.medical_treatmentVisual performanceOptical qualityReviewAstigmatismRefraction OcularPhakic intraocular lensPhakic refractive lens (PRL)CataractPupilEndophthalmitisLens Implantation IntraocularCataractsOphthalmologyRefractive surgeryMyopiamedicineHumansRefractive surgeryÓpticaPosterior chamber phakic intraocular lensbusiness.industryPatient SelectionEquipment Designmedicine.diseaseeye diseasesOphthalmologyAberrations of the eyemedicine.anatomical_structureLens (anatomy)Posterior Capsule of the LensOptometrysense organsbusinessEye
researchProduct

A comparison of the Canon TX-20P™ non-contact tonometer and pachymeter in healthy eyes

2012

Background: The aim of this study was to compare the intraocular pressure (IOP) and the central corneal thickness (CCT) measurements obtained with the Canon TX-20P™ with IOP measured with Goldmann applanation tonometer (GAT) and the CCT measured with ultrasound (US) pachymetry in healthy eyes. Methods: Thirty one healthy voluntary subjects participated in the study, age ranging from 16 to 81 years (mean age 50.9 years). In total 58 eyes were selected for analysis. All measurements were performed by the same examiner. The measurements were taken in the same order in all subjects: Canon IOP and CCT, Goldmann IOP and US CCT. Results: A strong correlation was found between IOP for both CCT comp…

Applanation tonometryIntraocular pressuremedicine.medical_specialtygenetic structuresbusiness.industrySignificant differenceGoldmann Applanation TonometerMean ageNon contact tonometereye diseasesOphthalmologyMedicineOptometrysense organsbusinessInternational Journal of Ophthalmic Practice
researchProduct

Effects of Ageing on the Anterior Segment of the Eye Structure and Function

2018

[Excerpt] The world will soon have more aged people than children and more people at extreme old age than ever before [1]. Improving quality of life as well as reducing severe disability due to age-related problems has become key for the health systems worldwide. The ageing of the world population has both structural and functional consequences for the human visual system; changes due to ageing occur in all the structures of the eye causing a variety of effects. Over the last few years, great advances in ophthalmic instrumentation allow the determination of ocular parameters to a level of detail without precedent. Such advances allowresearcherstodevelopspecificdevicesforvisualcorrection and r…

medicine.medical_specialtyScience & TechnologyArticle SubjectCiências Naturais::Ciências Físicasbusiness.industrymedia_common.quotation_subjectMEDLINE030204 cardiovascular system & hematology3. Good health03 medical and health sciencesOphthalmologyEditorial0302 clinical medicineText miningPhysical medicine and rehabilitationlcsh:Ophthalmologylcsh:RE1-994AgeingEye structureMedicineFunction (engineering)business030217 neurology & neurosurgerymedia_commonJournal of Ophthalmology
researchProduct