0000000000686708

AUTHOR

Matteo Albertini

showing 2 related works from this author

Advances in surfaces and osseointegration in implantology. Biomimetic surfaces

2015

The present work is a revision of the processes occurring in osseointegration of titanium dental implants according to different types of surfaces -namely, polished surfaces, rough surfaces obtained from subtraction methods, as well as the new hydroxyapatite biomimetic surfaces obtained from thermochemical processes. Hydroxyapatite’s high plasma-projection temperatures have proven to prevent the formation of crystalline apatite on the titanium dental implant, but lead to the formation of amorphous calcium phosphate (i.e., with no crystal structure) instead. This layer produce some osseointegration yet the calcium phosphate layer will eventually dissolve and leave a gap between the bone and …

medicine.medical_treatmentDentistryintegrationReviewcoatingsApatitelaw.inventionlawBiomimetic MaterialsImplants surfacesbioactive titaniumBiomimetics surfacesAmorphous calcium phosphateComposite materialCrystallizationDental implantTitaniumSuperfícies biomimètiquesImplantes dentalesSuperfícies d’implants:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludbone-formation adjacentSuperficies biomiméticasvisual_artUNESCO::CIENCIAS MÉDICASvisual_art.visual_art_mediumacidvivoLayer (electronics)biomimetics surfacesTitaniumMaterials scienceSurface Propertiesproliferationchemistry.chemical_elementOdontología616.3in-vitro:Enginyeria dels materials [Àrees temàtiques de la UPC]OsseointegrationBacterial colonizationfibronectinOsseointegrationmedicineAnimalsHumansGeneral DentistryBlood CoagulationDental ImplantsOral Medicine and PathologyImplants dentalsbusiness.industryDental implantsosseointegrationTitaniimplants surfacesSuperficies de implantesOtorhinolaryngologychemistryOsteointegraciónSurgerybusinessOsteointegració
researchProduct

Resonance frequency analysis-reliability in third generation instruments : Osstell mentor ®

2012

Few studies assess repeatability and reproducibility in registers of resonance frequency analysis (a value of dental implant stability). Objective: Few studies assess repeatability and reproducibility in resonance frequency analyses (implant stability evaluation). This study is aimed at assessing reliability (repeatabilty and reproducibility) in the Osstell Mentor® system using the intraclass correlation coefficient (ICC) as the statistical method. Study Design: ISQ measurements of RFA were carried out by means of the Osstell Mentor ® instrument in 58 implants in 19 patients. Six measurements were performed on each implant by means of two different Smart-Pegs (I and II). Three consecutive m…

medicine.medical_specialtyIntraclass correlationmedicine.medical_treatmentmedicineHumansPeriodontologyDental implantGeneral DentistryReliability (statistics)Dental ImplantsReproducibilitybusiness.industryReproducibility of ResultsRepeatability:CIENCIAS MÉDICAS [UNESCO]Confidence intervalSurgeryDental ImplantationResonance frequency analysisOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASResearch-ArticleSurgeryImplantbusinessBiomedical engineering
researchProduct