Magnitude of QRS duration reduction after biventricular pacing identifies responders to cardiac resynchronization therapy
Background Several studies have investigated the association between native QRS duration (QRSd) or QRS narrowing and response to biventricular pacing. However, their results have been conflicting. The aim of our study was to determine the association between the relative change in QRS narrowing index (QI) and clinical outcome and prognosis in patients who undergo cardiac resynchronization therapy (CRT) implantation. Methods and results We included 311 patients in whom a CRT device was implanted in accordance with current guidelines for CRT. On implantation, the native QRS, the QRSd and the QI during CRT were measured. After 6 months, 220 (71%) patients showed a 10% reduction in LVESV. The m…
Mortality after cardioverter-defibrillator replacement: Results of the DECODE survival score index
Background Device replacement is the ideal time to reassess health care goals regarding continuing implantable cardioverter-defibrillator (ICD) therapy. Only few data are available on the decision making at this time. Objectives The goals of this study were to identify factors associated with poor prognosis at the time of ICD replacement and to develop a prognostic index able to stratify those patients at risk of dying early. Methods DEtect long-term COmplications after implantable cardioverter-DEfibrillator replacement (DECODE) was a prospective, single-arm, multicenter cohort study aimed at estimating long-term complications in a large population of patients who underwent ICD/cardiac resy…