0000000000701781
AUTHOR
J. Cardoso
Response of the XENON100 dark matter detector to nuclear recoils
Results from the nuclear recoil calibration of the XENON100 dark matter detector installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), Italy are presented. Data from measurements with an external 241AmBe neutron source are compared with a detailed Monte Carlo simulation which is used to extract the energy dependent charge-yield Qy and relative scintillation efficiency Leff. A very good level of absolute spectral matching is achieved in both observable signal channels - scintillation S1 and ionization S2 - along with agreement in the 2-dimensional particle discrimination space. The results confirm the validity of the derived signal acceptance in earlier reported dark matte…
Early outcomes and complications following cardiac surgery in patients testing positive for coronavirus disease 2019: An international cohort study
The outbreak of severe acute respiratory syndromecoronavirus-2, the cause of coronavirus disease 2019 (COVID-19) in December 2019 represented a global emergency accounting for more than 2.5 million deaths worldwide.1 It has had an unprecedented influence on cardiac surgery internationally, resulting in cautious delivery of surgery and restructuring of services.2 Understanding the influence of COVID-19 on patients after cardiac surgery is based on assumptions from other surgical specialties and single-center studies. The COVIDSurg Collaborative conducted a multicenter cohort study, including 1128 patients, across 235 hospitals, from 24 countries demonstrating perioperative COVID-19 infection…
Dark Matter Search Results from a One Ton-Year Exposure of XENON1T
We report on a search for Weakly Interacting Massive Particles (WIMPs) using 278.8 days of data collected with the XENON1T experiment at LNGS. XENON1T utilizes a liquid xenon time projection chamber with a fiducial mass of $(1.30 \pm 0.01)$ t, resulting in a 1.0 t$\times$yr exposure. The energy region of interest, [1.4, 10.6] $\mathrm{keV_{ee}}$ ([4.9, 40.9] $\mathrm{keV_{nr}}$), exhibits an ultra-low electron recoil background rate of $(82\substack{+5 \\ -3}\textrm{ (sys)}\pm3\textrm{ (stat)})$ events/$(\mathrm{t}\times\mathrm{yr}\times\mathrm{keV_{ee}})$. No significant excess over background is found and a profile likelihood analysis parameterized in spatial and energy dimensions exclude…
Machine learning risk prediction of mortality for patients undergoing surgery with perioperative SARS-CoV-2: the COVIDSurg mortality score
The British journal of surgery 108(11), 1274-1292 (2021). doi:10.1093/bjs/znab183
Near band edge and defect emissions in wurtzite Cd0.025Mg0.10Zn0.875O nanocrystals
Abstract We report on near band edge and local defects emissions in Cd0·025Mg0·10Zn0·875O (CdMgZnO) nanoparticles (NPs) as a function of temperature, where a strong temperature-dependent near-infrared emission around 1.7 eV (~730 nm) has been observed. The NPs were synthesized by a modified sol-gel method and were annealed at 750 °C after growing. The crystallographic parameters have been determined by 2-dimensional synchrotron x-ray diffraction (XRD) and conventional XRD analysis, confirming their growth within the wurtzite phase with a preferred orientation along the (101) plane and an apparent crystallite size of 52.72 ± 0.18 nm. This apparent crystallite size is consistent with the near…