0000000000714284

AUTHOR

A. Finlay

showing 2 related works from this author

Dawning of the N=32 shell closure seen through precision mass measurements of neutron-rich titanium isotopes

2018

A precision mass investigation of the neutron-rich titanium isotopes 51 − 55 Ti was performed at TRIUMF’s Ion Trap for Atomic and Nuclear science (TITAN). The range of the measurements covers the N = 32 shell closure, and the overall uncertainties of the 52 − 55 Ti mass values were significantly reduced. Our results conclusively establish the existence of the weak shell effect at N = 32 , narrowing down the abrupt onset of this shell closure. Our data were compared with state-of-the-art ab initio shell model calculations which, despite very successfully describing where the N = 32 shell gap is strong, overpredict its strength and extent in titanium and heavier isotones. These measurements a…

Materials scienceNuclear Theorynucl-thNuclear TheoryAb initioGeneral Physics and Astronomychemistry.chemical_elementFOS: Physical sciences[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Mass spectrometrynucl-ex01 natural sciencesNuclear Theory (nucl-th)symbols.namesake0103 physical sciencesPhysics::Atomic and Molecular ClustersNeutron[ PHYS.NEXP ] Physics [physics]/Nuclear Experiment [nucl-ex]Nuclear Experiment (nucl-ex)010306 general physicsNuclear ExperimentNuclear ExperimentIsotope010308 nuclear & particles physicsStarke Wechselwirkung und exotische Kerne – Abteilung BlaumPenning trapchemistry13. Climate actionsymbolsIon trapAtomic physicsTitan (rocket family)Titanium
researchProduct

High-resolution, accurate MR-TOF-MS for short-lived, exotic nuclei of few events in their ground and low-lying isomeric states

2019

Mass measurements of fission and projectile fragments, produced via $^{238}$U and $^{124}$Xe primary beams, have been performed with the multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS) of the FRS Ion Catcher with a mass resolving powers (FWHM) up to 410,000 and an uncertainty of $6\cdot 10^{-8}$. The nuclides were produced and separated in-flight with the fragment separator FRS at 300 to 1000 MeV/u and thermalized in a cryogenic stopping cell. The data-analysis procedure was developed to determine with highest accuracy the mass values and the corresponding uncertainties for the most challenging conditions: down to a few events in a spectrum and overlapping distributions, ch…

Physics - Instrumentation and DetectorsFOS: Physical sciencesInstrumentation and Detectors (physics.ins-det)Nuclear Experiment (nucl-ex)Nuclear ExperimentNuclear Experiment
researchProduct