The summit hydrothermal system of Stromboli: New insights from self-potential, temperature, CO2 and fumarolic fluids measurements, with structural and monitoring implications.
International audience; Accurate and precisely located self-potential (SP), temperature (T) and COi measurements were carried out in the summit area of Stromboli along 72 straight profiles. SP data were acquired every metre and T data every 2.5 m. CO2 concentrations were acquired with the same density as T, but only along seven profiles. The high density of data and the diversity of the measured parameters allows us to study structures and phenomena at a scale rarely investigated. The shallow summit hydrothermal activity (Pizzo-Fossa area) is indicated by large positive SP, T and COi anomalies. These anomalies are focused on crater faults, suggesting that the fracture zones are more permeab…
Fluid circulation at Stromboli volcano (Aeolian Islands, Italy) from self-potential and CO2 surveys
This work addresses the study of fluid circulation of the Stromboli island using a dense coverage of self-potential (SP) and soil CO2 data. A marked difference exists between the northern flank and the other flanks of the island. The northern flank exhibits (1) a typical negative SP/altitude gradient not observed on the other flanks, and (2) higher levels of CO2. The general SP pattern suggests that the northern flank is composed of porous layers through which vadose water flows down to a basal water table, in contrast to the other flanks where impermeable layers impede the vertical flow of vadose water. In the Sciara del Fuoco and Rina Grande–Le Schicciole landslide complexes, breccias of …