Influence of blood sampling from venipunctures and catheter systems on serial determinations of prothrombin activation fragment 1 + 2 and thrombin-antithrombin III complex
To evaluate the influence of different blood sampling techniques on test results of thrombin-antithrombin III complex (TAT) and prothrombin fragment 1 + 2 (F1 + 2) serial determinations were performed. In six groups of nonrandomized patients (ten patients each) the concentrations of the coagulation markers of blood samples from central catheters (internal jugular, caval, Shaldon, pulmonary artery) and peripheral cannulas (17G and 18G) were compared with those of blood samples obtained simultaneously from direct venipunctures of the contralateral arm. Medians and 25th-75th percentiles of TAT and F1 + 2 concentrations of plasmas obtained from central catheters were not different from those ta…