0000000000803564

AUTHOR

Sergio Sciacca

Molecular Analysis With 16S rRNA PCR/Sanger Sequencing and Molecular Antibiogram Performed on DNA Extracted From Valve Improve Diagnosis and Targeted Therapy of Infective Endocarditis: A Prospective Study

Abstract Background Molecular analysis (MA) on heart valve (HV) improves the microbiologic diagnosis of infectious endocarditis (IE). The main drawback of MA is the lack of antimicrobial susceptibility information. Methods We conducted a prospective cohort observational study of consecutive adult patients from April 2012 to May 2021 who underwent valve surgery at our hospital. The performance of MA, blood cultures (BC) and valve cultures (VC), and the diagnostic and therapeutic impact of MA were evaluated. Molecular antibiogram results were compared to culture-based antimicrobial susceptibility testing (AST). Results A total of 137 patients with definite IE and 52 patients with no IE were e…

research product

A strange pneumonia

We report the case of a 62-year-old man with non-ST elevation myocardial infarction complicated by partial rupture of the antero-lateral papillary muscle in which severe mitral regurgitation with lateralized direction towards the right pulmonary veins gave unilateral pulmonary oedema, resembling an acute pneumonia.Unilateral pulmonary oedema is a rare entity, more frequently appearing as opacity of the right lung and always associated with severe mitral regurgitation. It is very important to suspect and promptly recognize unilateral pulmonary oedema because initial misdiagnosis leads to a delay in the initiation of appropriate treatment and to an increased risk of mortality.

research product

Usefulness of regional right ventricular and right atrial strain for prediction of early and late right ventricular failure following a left ventricular assist device implant: A machine learning approach

Background: Identifying candidates for left ventricular assist device surgery at risk of right ventricular failure remains difficult. The aim was to identify the most accurate predictors of right ventricular failure among clinical, biological, and imaging markers, assessed by agreement of different supervised machine learning algorithms. Methods: Seventy-four patients, referred to HeartWare left ventricular assist device since 2010 in two Italian centers, were recruited. Biomarkers, right ventricular standard, and strain echocardiography, as well as cath-lab measures, were compared among patients who did not develop right ventricular failure (N = 56), those with acute–right ventricular fail…

research product

Shear stress alterations in the celiac trunk of patients with a continuous-flow left ventricular assist device as shown by in-silico and in-vitro flow analyses

Background The use of left ventricular assist devices (LVADs) to treat advanced cardiac heart failure is constantly increasing, although this device leads to high risk for gastrointestinal bleeding. Methods Using in-silico flow analysis, we quantified hemodynamic alterations due to continuous-flow LVAD (HeartWare, Inc., Framingham, MA) in the celiac trunk and major branches of the abdominal aorta, and then explored the relationship between wall shear stress (WSS) and celiac trunk orientation. To assess outflow from the aortic branch, a 3-dimensional-printed patient-specific model of the celiac trunk reconstructed from an LVAD-supported patient was used to estimate echocardiographic outflow …

research product

Peripheral Artery Disease and Continuous Flow Left Ventricle Assist Device: An Engaging Complement Analysis May Help to Guide Treatment

Use of continuous flow left ventricle assist device (CF-LVAD) in advanced heart failure (HF) patients results in clinically relevant improvements in survival, functional capacity, and quality of life. Peripheral artery disease (PAD) can occur in patients with CF-LVAD due to the high rate of concomitance between risk factors for atherosclerosis and HF. Diagnosis of PAD can be difficult in the specific setting of a patient supported by this kind of device because of the marked alteration in waveform morphology and velocity created by the artificial physiology of an LVAD. We report the case of a 53-year-old man with HF secondary to ischemic cardiomyopathy supported by the HeartWare HVAD as bri…

research product

Should subcutaneous implantable cardioverter-defibrillators be implanted in patients who are candidates for continuous flow left ventricular assist device?

research product

Modeling Right Ventricle Failure After Continuous Flow Left Ventricular Assist Device: A Biventricular Finite-Element and Lumped-Parameter Analysis

The risk of right ventricle (RV) failure remains a major contraindication for continuous-flow left ventricular assist device (CF-LVAD) implantation in patients with heart failure. It is therefore critical to identify the patients who will benefit from early intervention to avoid adverse outcomes. We sought to advance the computational modeling description of the mechanisms underlying RV failure in LVAD-supported patients. RV failure was studied by computational modeling of hemodynamic and cardiac mechanics using lumped-parameter and biventricular finite element (FE) analysis. Findings were validated by comparison of bi-dimensional speckle-tracking echocardiographic strain assessment of the …

research product

Incidental Detection of a Giant Right Coronary Artery Aneurysm

research product