Shear stress alterations in the celiac trunk of patients with a continuous-flow left ventricular assist device as shown by in-silico and in-vitro flo…

2017

Background The use of left ventricular assist devices (LVADs) to treat advanced cardiac heart failure is constantly increasing, although this device leads to high risk for gastrointestinal bleeding. Methods Using in-silico flow analysis, we quantified hemodynamic alterations due to continuous-flow LVAD (HeartWare, Inc., Framingham, MA) in the celiac trunk and major branches of the abdominal aorta, and then explored the relationship between wall shear stress (WSS) and celiac trunk orientation. To assess outflow from the aortic branch, a 3-dimensional-printed patient-specific model of the celiac trunk reconstructed from an LVAD-supported patient was used to estimate echocardiographic outflow …

MalePulmonary and Respiratory Medicinemedicine.medical_specialtyLeft gastric arteryComputed Tomography Angiographyceliac trunkmedicine.medical_treatment0206 medical engineeringgastrointestinal bleedingHemodynamicsabdominal aorta02 engineering and technology030204 cardiovascular system & hematologyElectrocardiographycomputational fluid dynamic03 medical and health sciences0302 clinical medicineCeliac ArteryInternal medicinemedicine.arteryMultidetector Computed Tomographyleft ventricular assist deviceSettore ING-IND/12 - Misure Meccaniche E TermichemedicineHumansComputer SimulationTransplantationCommon hepatic arteryPhantoms Imagingbusiness.industryAbdominal aortaUltrasonography DopplerMiddle Agedmedicine.disease020601 biomedical engineeringTrunkOstiumVentricular assist deviceHeart failurecardiovascular systemCardiologyFemaleSurgeryHeart-Assist DevicesCardiology and Cardiovascular MedicinebusinessAlgorithmsBlood Flow VelocityThe Journal of Heart and Lung Transplantation
researchProduct

Computational Fluid-Dynamic Analysis after Carotid Endarterectomy: Patch Graft versus Direct Suture Closure.

2017

Background Closure technique after carotid endarterectomy (CEA) still remains an issue of debate. Routine use of patch graft (PG) has been advocated to reduce restenosis, stroke, and death, but its protective effect, particularly from late restenosis, is less evident and recent studies call into question this thesis. This study aims to compare PG and direct suture (DS) by means of computational fluid dynamics (CFD). To identify carotid regions with flow recirculation more prone to restenosis development, we analyzed time-averaged oscillatory shear index (OSI) and relative residence time (RRT), that are well-known indices correlated with plaque formation. Methods CFD was performed in 12 pati…

MalePatient-Specific Modelingmedicine.medical_specialtyTime Factorsmedicine.medical_treatmentHemodynamicsCarotid endarterectomy030204 cardiovascular system & hematologyMagnetic resonance angiography03 medical and health sciences0302 clinical medicineRestenosisRecurrenceInternal medicinemedicine.arterymedicineHumansCarotid StenosisCommon carotid arteryStrokeEndarterectomyAgedAged 80 and overEndarterectomy Carotidmedicine.diagnostic_testbusiness.industryAngioplastySuture TechniquesModels CardiovascularNumerical Analysis Computer-AssistedUltrasonography DopplerGeneral MedicineMiddle Agedmedicine.diseaseSurgeryStenosisCarotid ArteriesTreatment OutcomeRegional Blood FlowCardiologyHydrodynamicsSurgeryFemalebusinessCardiology and Cardiovascular Medicine030217 neurology & neurosurgeryMagnetic Resonance AngiographyAnnals of vascular surgery