0000000000843227

AUTHOR

Giuseppe Felici

0000-0002-3302-3765

showing 2 related works from this author

Detector for monitoring potential bleeding during electron intraoperative radiotherapy

2018

Purpose: The aim of this work is to develop a bleeding detector integrated into the acrylic circular applicators for specific mobile linacs. Thus, a bleeding detector has been developed based on a capacitive sensor to be used with plastic applicators, as in the case of LIAC HWL from Sordina IORT Technologies SpA. According to the clinical impact, we have selected 0.5 cm as the minimum depth of fluid that should be detected. Methods: An experiment was developed using water-simulating blood. Two setups were considered: non-beveled applicators with 7 cm and 10 cm diameter. Measurements were done for applicators 0 degrees and 45 degrees tilted, both with respect to the horizontal surface, in or…

Intraoperative radiotherapyMaterials scienceCapacitive sensingBiophysicsPhase (waves)General Physics and AstronomyElectronsHemorrhageRadiation030218 nuclear medicine & medical imagingIntraoperative Period03 medical and health sciences0302 clinical medicineOpticsRadiology Nuclear Medicine and imagingIrradiationRadiation InjuriesRadiotherapybusiness.industryBleedingContinuous monitoringDetectorLinearityGeneral MedicineBevel030220 oncology & carcinogenesisCapacitive sensorParticle AcceleratorsbusinessPhysica Medica
researchProduct

First Characterization of Novel Silicon Carbide Detectors with Ultra-High Dose Rate Electron Beams for FLASH Radiotherapy

2023

Ultra-high dose rate (UHDR) beams for FLASH radiotherapy present significant dosimetric challenges. Although novel approaches for decreasing or correcting ion recombination in ionization chambers are being proposed, applicability of ionimetric dosimetry to UHDR beams is still under investigation. Solid-state sensors have been recently investigated as a valuable alternative for real-time measurements, especially for relative dosimetry and beam monitoring. Among them, Silicon Carbide (SiC) represents a very promising candidate, compromising between the maturity of Silicon and the robustness of diamond. Its features allow for large area sensors and high electric fields, required to avoid ion r…

FLASH radiotherapy; Silicon Carbide; dosimetry; beam monitoring; UHDRFluid Flow and Transfer Processesbeam monitoringdosimetrySilicon CarbidePhysicsProcess Chemistry and TechnologyGeneral EngineeringSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Computer Science ApplicationsChemistryUHDRFLASH radiotherapyGeneral Materials ScienceHuman medicineInstrumentationApplied Sciences (Switzerland)
researchProduct