Base-isolated structure equipped with tuned liquid column damper: An experimental study

2019

Abstract In this study, a novel passive vibration control strategy is investigated experimentally, where a Tuned Liquid Column Damper protects a base-isolated structure. The Tuned Liquid Column Damper is attached to the base, in contrast to typical attachment points of passive energy dissipation devices in high-rise buildings at elevated levels. Experiments on a base-excited small-scale three-story shear frame are conducted in order to study effects of both control devices – base-isolation and Tuned Liquid Column Damper – on the structural model. The dynamic properties of the stand-alone shear frame and the base-isolation subsystem are derived using standard dynamic test methods based on di…

Optimal designOptimal design0209 industrial biotechnologyMaterials scienceAcousticsVibration controlAerospace Engineering02 engineering and technology01 natural sciencesTransfer functionDisplacement (vector)DamperAcceleration020901 industrial engineering & automation0103 physical sciencesTuned liquid column damper010301 acousticsCivil and Structural EngineeringMechanical EngineeringDissipationHybrid control strategyBase-isolated structureComputer Science ApplicationsControl and Systems EngineeringSmall-scale experimentSignal ProcessingDynamic testingMechanical Systems and Signal Processing
researchProduct

Optimal design of tuned liquid column dampers for seismic response control of base-isolated structures

2017

In this paper, the use of a tuned liquid column damper (TLCD) as a cost-effective means to control the seismic response of a base-isolated structure is studied. A straightforward direct approach for the optimal design of such a device is proposed, considering a white noise model of the base excitation. On this base, a direct optimization procedure of the TLCD design parameters is performed and optimal design charts are presented as a ready-to-use practical design tool. Comparison with the optimal parameters obtained considering a classical iterative statistical linearization technique proves the reliability of the proposed approach. The performance of the base-isolated TLCD-controlled struc…

Optimal designTuned Liquid Column DamperComputer scienceReliability (computer networking)Direct methodMechanical EngineeringDesign toolComputational Mechanics020101 civil engineering02 engineering and technologyWhite noiseBase (topology)0201 civil engineeringDamper020303 mechanical engineering & transports0203 mechanical engineeringControl theorySolid mechanicsSettore ICAR/08 - Scienza Delle CostruzioniBase isoltation
researchProduct

Earthquake Excited Base-Isolated Structures Protected by Tuned Liquid Column Dampers: Design Approach and Experimental Verification

2017

Abstract In this contribution a direct approach for optimal design of a Tuned Liquid Column Damper (TLCD) device attached to the base slab of a base-isolated structure is presented, aiming at reducing the seismic displacement demand of the base-isolation subsystem. Assuming white noise base excitation, for a wide parameter range a direct optimization procedure yields design charts for optimal TLCD quantities. The performance of the base-isolated structure equipped with optimally tuned TLCD device in comparison to the simple base-isolated one is evaluated both numerically and experimentally. In a numerical study the system is subjected to the 44 records of the FEMA P-695 far-field ground mot…

Optimal designBase-isolationOptimal designEngineeringbusiness.industryDirect methodBase (geometry)020101 civil engineering02 engineering and technologyGeneral MedicineWhite noiseStructural engineering0201 civil engineeringDamperShear (sheet metal)020303 mechanical engineering & transports0203 mechanical engineeringRange (statistics)SlabHybrid passive controlTLCDbusinessSettore ICAR/08 - Scienza Delle Costruzioni