0000000000870743

AUTHOR

Wolfgang Bicker

Case report: Another death associated to γ-hydroxybutyric acid intoxication

Abstract We report a fatal γ-hydroxybutyric acid (GHB) intoxication of a forty-year old man. According to an acquaintances’ statement, the deceased had drunk a beverage containing GHB approximately five hours before he was found. Postmortem GHB concentrations were determined using gas chromatography coupled to single quadrupole mass spectrometry after simple protein precipitation with methanol and derivatization with BSTFA (1% TMCS). Concentrations in body fluids and tissues of the deceased were as follows: cardiac blood 384 mg/L, femoral blood 358 mg/L, urine 864 mg/L, brain tissue 211 mg/kg, liver tissue 201 mg/kg, kidney tissue 492 mg/kg, bile 334 mg/L and gastric content 2025 mg/L. In a…

research product

Stable-bond polymeric reversed-phase/weak anion-exchange mixed-mode stationary phases obtained by simultaneous functionalization and crosslinking of a poly(3-mercaptopropyl)methylsiloxane-film on vinyl silica via thiol-ene double click reaction.

Abstract A polymeric reversed-phase/weak anion exchange (Poly-RP/WAX) mixed-mode stationary phase has been prepared by coating of a poly(3-mercaptopropyl)methylsiloxane film on vinyl-modified silica (100 A, 5 μm) and simultaneous in situ functionalization with N-(10-undecenoyl)-3-aminoquinuclidine as well as crosslinking to the vinyl silica surface by solventless thiol-ene double click reaction. Such bonding chemistry showed greatly enhanced stability compared to brush-type analogs with bifunctional siloxane bonding to silica. Solid-state 29Si-CP/MAS NMR confirmed the immobilization of the siloxane layer. pH-Dependent ζ-potential determinations revealed a high anion-exchange capacity over t…

research product

Determination of ethyl sulfate – a marker for recent ethanol consumption – in human urine by CE with indirect UV detection

A CE method for the determination of the ethanol consumption marker ethyl sulfate (EtS) in human urine was developed. Analysis was performed in negative polarity mode with a background electrolyte composed of 15 mM maleic acid, 1 mM phthalic acid, and 0.05 mM cetyltrimethylammonium bromide (CTAB) at pH 2.5 and indirect UV detection at 220 nm (300 nm reference wavelength). This buffer system provided selective separation conditions for EtS and vinylsulfonic acid, employed as internal standard, from urine matrix components. Sample pretreatment of urine was minimized to a 1:5 dilution with water. The optimized CE method was validated in the range of 5-700 mg/L using seven lots of urine. Intra-…

research product