0000000000870777

AUTHOR

Alfredo Campennì

showing 2 related works from this author

Transcranial Doppler ultrasonography in the assessment of cerebral circulation arrest: improving sensitivity by trancervical and transorbital carotid…

2009

INTRODUCTION: Transcranial Doppler (TCD) can detect the cerebral circulation arrest (CCA) in brain death. TCD is highly specific, but less sensitive because of false-negatives accounting for up to 10%. The aim of the study was to explore the diagnostic accuracy of TCD and to determine whether it can be augmented by strategies such as the insonation of the extracranial internal carotid artery (ICA) and sequential examinations. METHODS: Data of 184 patients, who met clinical criteria of brain death, observed from 1998 through 2006, were retrospectively reviewed. The study of cerebral arteries was performed through the transtemporal approach, suboccipital insonation of the vertebro-basilar sys…

Adultcerebral circulation arrest (CCAmedicine.medical_specialtyBrain DeathNeurologybusiness.operationAdolescentUltrasonography Doppler TranscranialDiagnostic accuracyCritical Care and Intensive Care MedicineCohort StudiesCerebral circulationYoung AdultPredictive Value of Testsmedicine.arteryMedicineHumansChildAgedRetrospective StudiesAged 80 and overbusiness.industryTranscranial doppler cerebral circulatory arrest brain deathSettore MED/27 - Neurochirurgia) brain death.fungifood and beveragesInfantReproducibility of ResultsMiddle AgedTranscranial DopplerTranscranial Doppler ultrasonographyRegional Blood FlowCerebrovascular CirculationChild PreschoolTranscranial Doppler (TCD)cardiovascular systemNeurology (clinical)RadiologyInternal carotid arterybusinessTransorbitalCarotid Artery Internal
researchProduct

Treatment of hyperthyroidism with radioiodine targeted activity: A comparison between two dosimetric methods.

2016

Radioiodine therapy is an effective and safe treatment of hyperthyroidism due to Graves' disease, toxic adenoma, toxic multinodular goiter. We compared the outcomes of a traditional calculation method based on an analytical fit of the uptake curve and subsequent dose calculation with the MIRD approach, and an alternative computation approach based on a formulation implemented in a public-access website, searching for the best timing of radioiodine uptake measurements in pre-therapeutic dosimetry. We report about sixty-nine hyperthyroid patients that were treated after performing a pre-therapeutic dosimetry calculated by fitting a six-point uptake curve (3-168h). In order to evaluate the res…

MaleRadioiodine uptakeBiophysicsGeneral Physics and AstronomyHyperthyroidism030218 nuclear medicine & medical imagingIodine Radioisotopes03 medical and health sciences0302 clinical medicineTreatment planMultinodular goiterDosimetryMedicineHumansRadiology Nuclear Medicine and imagingInternal dosimetryRadiometryAgedbusiness.industryRadioiodine therapyGeneral MedicineMiddle AgedBiokinetics Hyperthyroidism Internal dosimetry Radioiodine therapy030220 oncology & carcinogenesisPatient dosimetryFemaleNuclear medicinebusinessAfter treatmentFollow-Up StudiesPhysica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)
researchProduct