Abstract A drilled plate of ferromagnetic material suitably coupled by coils of enameled copper wire fed by a DC power supply to 30 V is considered in this paper. It is analyzed with finite element and later experiments are performed to validate the obtained results. After polishing the plate, two strain gauges for measuring the deformation along the x axis and along the z axis are installed. The values of strain are 5 μm/m in z direction and −2 μm/m in x direction. The experimental–numerical comparison shows that the laboratory results are lower than numerical, while signs and orders of magnitude are the same. It is concluded that the results of the FEM analysis can be considered acceptabl…