PVA gel dosimeters for radiotherapy applications,

Gel dosimeters for three-dimensional mapping of radiotherapy doses were introduced at Yale University in the mid-1980’s. Soon after, research and development in this field also started in Italy. Early work was done at the Istituto Superiore di Sanità, and at the Universities of Pisa and Milan. Several institutes now collaborate on this topic with the goal of developing new formulations of hydrogel matrices with improved characteristics of stability, sensitivity and spatial resolution compared to those of earlier Fricke-gel and polymer-gel systems. Contrary to earlier gels based on natural gelling agents, such as porcine skin gelatin and/or agarose, which suffer from limited batch -to-batch …

research product

Gel di Fricke: studio della risposta NMR in funzione della concentrazione di ferro ed utilizzo dosimetrico in ambito clinico (3D MRI)

research product

Nuclear Magnetic Resonance investigation of PVA-GTA FRicke gel dosimeters exposed to clinical photon beams

Fricke Xylenol Gel (FXG) dosimetric system is based on the radiation induced oxidation of ferrous (Fe2+) to ferric (Fe3+) ions. The application of Fricke gels for ionizing radiation dosimetry is continuously increasing worldwide due to their many favorable properties. However, one of their shortcomings is that ferrous and ferric ions diffuse in the gel matrix. To maintain the spatial integrity of the dose distribution, Fricke gels must be undergoing measurement within a few hours of their irradiation, so that ferric ions remain close to their point of production. Thus, the spatial integrity of the dose distribution in the Fricke gel is maintained. The gel matrix also contributes to the oxid…

research product

Characterization of Fricke gel dosimeters exposed to gamma rays and neutrons

research product

PVA-GTA Fricke gel: studio della risposta NMR in funzione della concentrazione degli additivi e studi preliminari con scanner MRI 7 T

Sono stati analizzati tramite rilassometria NMR ed acquisizioni MRI dosimetri gel di tipo Fricke realizzati utilizzando un'innovativa matrice gel sintetica e tessuto equivalente: Polyvinyl alcohol (PVA) attivando chimicamente il processo di gelificazione tramite l'aggiunta di Glutaraldehyde (GTA). Questi gel sono stati irradiati con fasci di fotoni (LINAC) nel range 0--20 Gy. Per valutare la sensibilità a fotoni è stata studiata la dipendenza dei tempi di rilassamento nucleari dalla dose e dalla concentrazione di ferro nei gel. Inoltre è stata monitorata la stabilità del segnale dopo l'irraggiamento. Acquisizioni preliminari MRI con uno scanner MRI da 7 T sono state affiancate alle misure N…

research product

Sensibilità e stabilità dei dosimetri gel di tipo Fricke esposti ai fotoni nel range clinico in funzione della concentrazione di ferro: 3D MRI ed applicazioni dosimetriche

research product

Dependence of MRI sensitivity of Fricke gel dosimeters exposed to clinical photons beams on ferrous ammonium sulfate content