0000000000934609

AUTHOR

F. Hagenbuck

The 1.5GeV harmonic double-sided microtron at Mainz University

Abstract At the Institut fur Kernphysik of Mainz University a harmonic double-sided microtron (HDSM) has been built to extend the experimental capabilities for nuclear and particle physics experiments to higher excitation energies. This novel microtron variant accelerates the 0.855 GeV continuous wave (cw) electron beam of the established three-staged race track microtron (RTM) cascade MAMI B up to 1.5 GeV. It consists of two normal conducting linear accelerators (linacs) through which the electrons are guided up to 43 times by a pair of 90°-bending magnets at each end. For beam dynamical reasons the linacs operate at the harmonic frequencies of 4.90 and 2.45 GHz. The extended facility is c…

research product

Novel digital K-edge imaging system with transition radiation from an 855-MeV electron beam

A novel K-edge imaging method has been developed at the Mainz Microtron MAMI aiming at a very efficient use of the transition radiation (TR) flux generated by the external 855-MeV electron beam in a foil stack. A fan-like quasi-monochromatic hard X-ray beam is produced from the /spl plusmn/1-mrad-wide TR cone with a highly oriented pyrolytic graphite (HOPG) crystal. The absorption of the object in front of a 30 mm/spl times/10 mm pn charge-coupled device (pn-CCD) photon detector is measured at every pixel by a broad-band energy scan around the K-absorption edge. This is accomplished by a synchronous variation of the lateral crystal position and the electron beam direction which defines also…

research product

Observation of optical Smith-Purcell radiation at an electron beam energy of 855 MeV.

Smith-Purcell radiation, generated when a beam of charged particles passes close to the surface of a diffraction grating, has been studied in the visible spectral range at wavelengths of 360 and 546 nm with the low emittance 855 MeV electron beam of the Mainz Microtron MAMI. The beam focused to a spot size of $4 \ensuremath{\mu}\mathrm{m}$ (full width at half maximum) passed over optical diffraction gratings of echelle profiles with blaze angles of $0.8\ifmmode^\circ\else\textdegree\fi{}, 17.27\ifmmode^\circ\else\textdegree\fi{},$ and $41.12\ifmmode^\circ\else\textdegree\fi{}$ and grating periods of 0.833 and $9.09 \ensuremath{\mu}\mathrm{m}.$ Taking advantage of the specific emission chara…

research product

How narrow is the linewidth of parametric X-ray radiation?

Parametric x-ray or quasi-Cherenkov radiation is produced by the passage of an electron through a crystal. A critical absorber technique has been employed to investigate its linewidth. Experiments have been performed with the 855MeV electron beam from the Mainz Microtron MAMI. Thin absorber foils were mounted in front of a CCD camera serving as a position sensitive photon detector. Upper limits of the linewidth of 1.2 and 3.5eV were determined for the (111) and (022) reflections of silicon at photon energies of 4966 and 8332eV. These limits originate from geometrical line broadening effects that can be optimized to reach the ultimate limit given by the finite length of the wave train. {copy…

research product

Transition radiation in the x-ray region from a low emittance 855 MeV electron beam

A quasi-monochromatic hard x-ray beam with a photon energy of 33 keV has been produced from transition radiation (TR) at the Mainz Microtron MAMI. The radiator was a stack of 30 polyimide foils of 25 μm thickness and 75 μm separation and the monochromator a highly-oriented pyrolytic graphite crystal. The intrinsic bandwidth was measured with a critical absorption technique to be 100 eV. On the basis of these experiments a photon flux of 4⋅109/mm2s over an illuminated area of 5.7×125 mm2 can be expected from an optimized beryllium radiator at a beam current of 100 μA. At the K-absorption edge of titanium at 5 keV narrow band transition radiation has been observed from a stack of four foils o…

research product