0000000000959270

AUTHOR

Juhani Smolander

Adding a cooling vest during cycling improves performance in warm and humid conditions

It is known that warm and humid environment reduces human physical performance. The present study examined whether the use of an ice-vest in such conditions can improve cycling performance. Seven participants cycled with consecutive, non-stop, 10-minute cycles of nine minutes at 60% of their (V) over dot O-2 max punctuated by a one-minute sprint at 80% (V) over dot O-2 max. The cycling protocol was continuously repeated until exhaustion. The protocol was performed with the ice-vest (ICE), worn after 30 min of cycling, and without the ice-vest throughout the protocol (CON). Ventilatory and thermal responses were continuously recorded. Electromyographic (EMG) signals from four muscles of the …

research product

A new heart rate variability-based method for the estimation of oxygen consumption without individual laboratory calibration: Application example on postal workers

Traditionally, the estimation of oxygen consumption (VO2) at work using heart rate (HR) has required the determination of individual HR/VO2 calibration curves in a separate exercise test in a laboratory (VO2-TRAD). Recently, a new neural network-, and heart rate variability-based method has been developed (Firstbeat PRO heartbeat analysis software) for the estimation of VO2 without individual calibration (VO2-HRV). In the present study, the VO2-values by the VO2-HRV were compared with the values by VO2-TRAD in 22 postal workers. Within individuals the correlation between the two methods was high (range 0.80-0.99). The VO2-TRAD gave higher values of VO2 compared to VO2-HRV (19%) especially d…

research product

Lung function after acute and repeated exposures to extremely cold air (-110 degrees C) during whole-body cryotherapy.

Whole-body cryotherapy (WBC) is one mode of cold therapy, during which rheumatic patients are exposed to very cold air (-110 degrees C) in minimal clothing. It is also proposed to have a bronchodilatory effect. The aim was to examine the effects of WBC on lung function in healthy humans after acute and repeated exposures. Twenty-five healthy, non-smoking subjects participated in the study. They were exposed to WBC for 2 min three times per week for 12 weeks. The peak expiratory flow rate (PEF) and forced expiratory volume in 1 s (FEV1) were measured before and after (at 2 and 30 min) the first WBC, and then similarly at 4, 8 and 12 weeks. At all time points, after 30 min of the WBC the PEF …

research product

Estimating oxygen consumption from heart rate and heart rate variability without individual calibration

Heart rate (HR) as an estimator of oxygen consumption (VO(2) ) usually requires HR to be individually calibrated in a separate test. This study examined the validity of a new HR - and HR variability-based method (Firstbeat PRO heartbeat analysis software) in the estimation of VO(2) in real-life tasks. The method takes into account the respiration rate determined from HR variability and the differences in the on/off dynamics of HR and VO(2) , and no calibration tests are needed. Ten men and nine women performed 25 tasks representing different types of daily activities. Portable devices were used to measure R-to-R intervals (ECG), VO(2) and respiration rate. In pooled regression analysis, the…

research product