0000000000977943

AUTHOR

F. Schneider

showing 24 related works from this author

Classical and Quantum Two-Dimensional Fluids in the Gibbs Ensemble

1994

We study the properties of model fluids in two spatial dimensions with Gibbs ensemble Monte Carlo (GEMC) techniques. In particular in the first part of the paper we study the entropy driven phase separation in case of a nonadditive symmetric hard disc fluid and locate by a combination of GEMC with finite size scaling techniques the critical line of nonadditivities as a function of the system density, which separates the mixing/demixing regions, we compare with a simple approximation. In the second part we successfully combine path integral Monte Carlo (PIMC) and GEMC techniques in order to locate the gas-liquid coexistence densities for a fluid with classical degrees of freedom and internal…

Canonical ensembleStatistical ensemblePhysicsMicrocanonical ensemblesymbols.namesakeIsothermal–isobaric ensembleMonte Carlo methodsymbolsStatistical physicsGibbs measureQuantum statistical mechanicsPath integral Monte Carlo
researchProduct

Phase transitions in nonadditive hard disc systems: a Gibbs ensemble Monte Carlo Study

2007

we study the properties of a model fluid in two dimensions with Gibbs ensemble Monte Carlo (GEMC) techniques, in particular we analyze the entropy-driven phase separation in case of a nonadditive symmetric hard disc fluid. By a combination of GEMC with finite size scaling techniques we locate the critical line of nonadditivities as a function of the system density, which separates the mixing/demixing regions and compare with a simple analytical approximation.

Condensed Matter::Soft Condensed MatterCanonical ensemblePhysicsPhase transitionCritical lineMonte Carlo methodDynamic Monte Carlo methodStatistical physicsFunction (mathematics)ScalingMixing (physics)
researchProduct

Implementation of an aerodynamic lens for TRIGA-SPEC

2016

Abstract We report on the optimization of the gas-jet system employed to couple the TRIGA-SPEC experiment to the research reactor TRIGA Mainz. CdI2 aerosol particles suspended in N2 as carrier gas are used for an effective transport of fission products from neutron induced 235 U fission from the target chamber to a surface ion source. Operating conditions of the gas-jet were modified to enable the implementation of an aerodynamic lens, fitting into the limited space available in front of the ion source. The lens boosts the gas-jet efficiency by a factor of 4–10. The characterization of the gas-jet system as well as the design of the aerodynamic lens and efficiency studies are presented and …

Nuclear and High Energy PhysicsFission products010504 meteorology & atmospheric sciencesChemistrybusiness.industryFissionNuclear engineeringAerodynamics010403 inorganic & nuclear chemistry01 natural sciencesIon source0104 chemical sciencesTRIGAlaw.inventionLens (optics)OpticslawResearch reactorNeutronbusinessInstrumentation0105 earth and related environmental sciencesNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

High efficiency resonance ionization of palladium with Ti:sapphire lasers

2016

This work presents the development and testing of highly efficient excitation schemes for resonance ionization of palladium. To achieve the highest ionization efficiencies, a high-power, high repetition rate Ti:sapphire laser system was used and 2-step, 3-step and 4-step schemes were investigated and compared. Starting from different excited steps, the frequencies of the final ionization steps were tuned across the full accessible spectral range of the laser system, revealing several autoionizing Rydberg series, which converge towards the energetically higher lying state of the Pd+ ion ground state configuration. Through proper choice of these excitation steps, we developed a highly efficie…

010302 applied physicsPhysicsResonanceCondensed Matter PhysicsLaser01 natural sciencesAtomic and Molecular Physics and OpticsIon sourcelaw.inventionIonlawIonizationExcited state0103 physical sciencesPhysics::Atomic PhysicsAtomic physics010306 general physicsGround stateExcitationJournal of Physics B: Atomic, Molecular and Optical Physics
researchProduct

Production, isolation and characterization of radiochemically pure 163Ho samples for the ECHo-project

2018

Abstract Several experiments on the study of the electron neutrino mass are based on high-statistics measurements of the energy spectrum following electron capture of the radionuclide 163Ho. They rely on the availability of large, radiochemically pure samples of 163Ho. Here, we describe the production, separation, characterization, and sample production within the Electron Capture in Holmium-163 (ECHo) project. 163Ho has been produced by thermal neutron activation of enriched, prepurified 162Er targets in the high flux reactor of the Institut Laue-Langevin, Grenoble, France, in irradiations lasting up to 54 days. Irradiated targets were chemically processed by means of extraction chromatogr…

ChromatographyChemistryEcho (computing)lanthanide separationneutron activation[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]010403 inorganic & nuclear chemistryIsolation (microbiology)7. Clean energy01 natural sciencesNeutrino mass determination0104 chemical sciencesCharacterization (materials science)163Ho0103 physical sciencesextraction chromatographyPhysical and Theoretical Chemistry010306 general physicsNeutron activationRadiochimica Acta
researchProduct

A gas-jet apparatus for high-resolution laser spectroscopy on the heaviest elements at SHIP

2020

© 2019 Elsevier B.V. Laser spectroscopy enables the determination of fundamental atomic and nuclear properties with high precision. In view of the low production rates of the heaviest elements, a high total efficiency is a crucial requirement for any experimental setup to be used in on-line experiments. The setup requires the use of gas stopping techniques to slow down the radionuclides of interest. In previous studies laser spectroscopy was performed inside a gas-filled stopping cell with a limited spectral resolution of a few GHz. Collisional broadening inside stopping cells ultimately limits the precision of laser spectroscopic studies and hampers in particular hyperfine spectroscopy. Th…

Nuclear and High Energy PhysicsJet (fluid)Materials science010308 nuclear & particles physicsbusiness.industryResolution (electron density)chemistry.chemical_elementLaser7. Clean energy01 natural scienceslaw.inventionLaser linewidthOpticschemistrylaw0103 physical sciencesNobeliumSpectral resolution010306 general physicsSpectroscopybusinessInstrumentationHyperfine structure
researchProduct

ChemInform Abstract: Cyclic Esters of Aliphatic Diacids with Pyrocatechol and Hydroquinone.

1986

Cyclic esters of adipic acid, suberic acid and sebacic acid were prepared by reaction of the acid dichlorides and pyrocatechol or hydroquinone in benzene under high dilution conditions. While only the cyclic dimers could be obtained from hydroquinone, pyrocatechol formed cyclic monomers as well as cyclic dimers (and also a cyclic dimer with succinic acid). The structure of all compounds was confirmed by1H-NMR- and mass spectra. The crystal structures of the pyrocatechol esters were determined by single crystal X-ray analysis.

chemistry.chemical_compoundMonomerAdipic acidchemistrySebacic acidHydroquinoneSuccinic acidDimerPolymer chemistryOrganic chemistryGeneral MedicineSuberic acidBenzeneChemischer Informationsdienst
researchProduct

Path integral Monte Carlo study of the internal quantum state dynamics of a generic model fluid

1996

We study the quantum dynamics of a generic model fluid with internal quantum states and classical translational degrees of freedom in two spatial dimensions. The path integral Monte Carlo data for the imaginary time correlation functions are presented and analyzed by the maximum entropy method. A comparison of the frequency distribution with those of a mean field approximation and virial expansion shows good agreement at high and low densities, respectively. \textcopyright{} 1996 The American Physical Society.

Hybrid Monte CarloQuantum dynamicsQuantum Monte CarloMonte Carlo methodMonte Carlo integrationDiffusion Monte CarloStatistical physicsPath integral Monte CarloMathematicsMonte Carlo molecular modelingPhysical Review E
researchProduct

Hot-cavity studies for the Resonance Ionization Laser Ion Source

2016

International audience; The Resonance Ionization Laser Ion Source (RILIS) has emerged as an important technique in many Radioactive Ion Beam (RIB) facilities for its reliability, and ability to ionize target elements efficiently and element selectively. GISELE is an off-line RILIS test bench to study the implementation of an on-line laser ion source at the GANIL separator facility. The aim of this project is to determine the best technical solution which combines high selectivity and ionization efficiency with small ion beam emittance and stable long term operation. The ion source geometry was tested in several configurations in order to find a solution with optimal ionization efficiency an…

010302 applied physicsPhysicsNuclear and High Energy PhysicsIon beamTitanium sapphire laser[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Ion gun7. Clean energy01 natural sciencesIon sourceAtmospheric-pressure laser ionizationHot cavityRadioactive Ion BeamWork function materialResonant Ionization Laser Ion SourceIon beam depositionIonization0103 physical sciencesPhysics::Accelerator PhysicsThermal emittanceAtomic physicsBeam emittance010306 general physicsInstrumentation
researchProduct

Status and recent developments at the polarized-electron injector of the superconducting Darmstadt electron linear accelerator S-DALINAC

2011

At the superconducting Darmstadt electron linac a 100 keV source of polarized electrons has been installed. Major components had been tested prior to installation at an offline teststand. Commissioning of the new source at the S-DALINAC will take place early in 2011. We report on the performance of the teststand, simulations, developments on the laser systems, new radio-frequency components for the S-DALINAC injector, and the status of the implementation of the source.

SuperconductivityPhysicsHistoryInjectorElectronLaserElectromagnetic radiationLinear particle acceleratorComputer Science ApplicationsEducationlaw.inventionNuclear physicsElectron linear acceleratorlawLeptonJournal of Physics: Conference Series
researchProduct

TRIGA-SPEC: the prototype of MATS and LaSpec

2015

Investigation of short-lived nuclei is a challenging task that MATS and LaSpec will handle at the low energy branch of Super-FRS at FAIR. The groundwork for those experiments is laid-out already today at the TRIGA-SPEC facility as a powerful development platform located at the research reactor TRIGA Mainz. The latest status, new developments and first results of commissioning runs are presented here.

HistoryEngineeringSpeichertechnik - Abteilung Blaumbusiness.industryNuclear engineeringMechanical engineeringSpec#Computer Science ApplicationsEducationTRIGATask (project management)Low energyResearch reactorbusinesscomputercomputer.programming_language
researchProduct

Progress of resonant ionization laser ion source development at GANIL.

2014

SPIRAL2 (Systeme de Production d’Ions Radioactifs Acceleres en Ligne) is a research facility under construction at GANIL (Grand Accelerateur National d’Ions Lourds) for the production of radioactive ion beams by isotope separation on-line methods and low-energy in-flight techniques. A resonant ionization laser ion source will be one of the main techniques to produce the radioactive ion beams. GISELE (GANIL Ion Source using Electron Laser Excitation) is a test bench developed to study a fully operational laser ion source available for Day 1 operations at SPIRAL2 Phase 2. The aim of this project is to find the best technical solution which combines high selectivity and ionization efficiency w…

PhysicsIon beam[PHYS.PHYS.PHYS-ACC-PH]Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]Particle acceleratorLaserIon sourcelaw.inventionIsotope separationNuclear physicsIon beam depositionPhysics::Plasma Physicslaw[PHYS.PHYS.PHYS-PLASM-PH]Physics [physics]/Physics [physics]/Plasma Physics [physics.plasm-ph]IonizationPhysics::Accelerator PhysicsThermal emittanceAtomic physicsGISELEInstrumentationSPIRAL2ComputingMilieux_MISCELLANEOUSThe Review of scientific instruments
researchProduct

First online operation of TRIGA-TRAP

2020

Abstract We report on the successful coupling of the Penning-trap mass spectrometry setup TRIGA-TRAP to the research reactor TRIGA Mainz. This offers the possibility to perform direct high-precision mass measurements of short-lived nuclei produced in neutron-induced fission of a 235 U target located near the reactor core. An aerosol-based gas-jet system is used for efficient transport of short-lived neutron-rich nuclei from the target chamber to a surface ion source. In conjunction with new ion optics and extended beam monitoring capabilities, the experimental setup has been fully commissioned. The design of the surface ion source, efficiency studies and first results are presented.

PhysicsSpeichertechnik - Abteilung BlaumNuclear and High Energy PhysicsFission products010308 nuclear & particles physicsFissionNuclear engineeringNuclear TheoryMass spectrometry01 natural sciencesIon sourceTRIGAIonNuclear reactor core0103 physical sciencesResearch reactorNuclear Experiment010306 general physicsInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Highly efficient isotope separation and ion implantation of  163Ho for the ECHo project

2019

Abstract The effective electron neutrino mass measurement in the framework of the ECHo experiment requires radiochemically pure 163 Ho, which is ion implanted into detector absorbers. To meet the project specifications in efficiency and purity, the entire process chain of ionization, isotope separation , and implantation of 163Ho was optimized. A new two-step resonant laser ionization scheme was established at the 30 kV magnetic mass separator RISIKO. For ionization and separation, an average efficiency of 69 ( 5 )  stat(4)sys% was achieved using intra-cavity frequency doubled Ti:sapphire lasers. The implantation of undesired 166 m Ho, which is present in trace amounts in the initial  163Ho…

Accelerator Physics (physics.acc-ph)PhysicsNuclear and High Energy PhysicsAtomic Physics (physics.atom-ph)Orders of magnitude (temperature)DetectorAnalytical chemistryFOS: Physical sciencesLaser01 natural sciencesPhysics - Atomic Physics010305 fluids & plasmasIsotope separationlaw.inventionIonIon implantationlawIonization0103 physical sciencesSapphirePhysics - Accelerator Physics010306 general physicsInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Resonance ionization of holmium for ion implantation in microcalorimeters

2016

Abstract The determination of the electron neutrino mass by calorimetric measurement of the 163 Ho electron capture spectrum requires ultra-pure samples. Several collaborations, like ECHo or HOLMES, intend to employ microcalorimeters into which 163 Ho is implanted as an ion beam. This makes a selective and additionally very efficient ion source for holmium mandatory. For this purpose, laser resonance ionization of stable holmium 165 Ho was studied, using a three step excitation scheme driven by pulsed Ti:sapphire lasers. Five measurements with sample sizes of 10 14 and 10 15 atoms were performed for the efficiency investigation. In average, an excellent ionization efficiency of 32(5) % coul…

Nuclear and High Energy PhysicsIon beamChemistrychemistry.chemical_elementMass spectrometry01 natural sciencesIon source010305 fluids & plasmasAtmospheric-pressure laser ionizationIon beam depositionIon implantationIonization0103 physical sciencesAtomic physics010306 general physicsHolmiumInstrumentationNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

A White Paper on keV sterile neutrino Dark Matter

2017

We present a comprehensive review of keV-scale sterile neutrino Dark Matter, collecting views and insights from all disciplines involved - cosmology, astrophysics, nuclear, and particle physics - in each case viewed from both theoretical and experimental/observational perspectives. After reviewing the role of active neutrinos in particle physics, astrophysics, and cosmology, we focus on sterile neutrinos in the context of the Dark Matter puzzle. Here, we first review the physics motivation for sterile neutrino Dark Matter, based on challenges and tensions in purely cold Dark Matter scenarios. We then round out the discussion by critically summarizing all known constraints on sterile neutrin…

AstrofísicaSterile neutrinocosmological modelCold dark mattercosmological neutrinosPhysics beyond the Standard Model[ PHYS.ASTR ] Physics [physics]/Astrophysics [astro-ph]Dark matter theory01 natural sciencesCosmologyHigh Energy Physics - ExperimentHigh Energy Physics - Experiment (hep-ex)White paperHigh Energy Physics - Phenomenology (hep-ph)X-RAY-EMISSIONMETALLIC MAGNETIC CALORIMETERSQUANTUM-FIELD THEORY[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]neutrino: dark matterCosmological neutrinos; Dark matter experiments; Dark matter theory; Particle physics - cosmology connection010303 astronomy & astrophysicsPhysicsdark matter theorynew physicsDOUBLE-BETA-DECAYhep-phneutrino: sterileCosmological neutrinos; Dark matter experiments; Dark matter theory; Particle physics - cosmology connection; Astronomy and AstrophysicsNuclear & Particles PhysicsHigh Energy Physics - Phenomenologyneutrino: detectorDark matter experimentsparticle physics - cosmology connectionastro-ph.COMILKY-WAY SATELLITESCosmological neutrinos3.5 KEV LINENeutrinoParticle Physics - ExperimentAstrophysics - Cosmology and Nongalactic AstrophysicsParticle physicsAstrophysics and AstronomyCosmology and Nongalactic Astrophysics (astro-ph.CO)astro-ph.GADark matterLY-ALPHA FORESTreviewFOS: Physical sciencesContext (language use)neutrino: productionX-raySettore FIS/05 - Astronomia e Astrofisica[ PHYS.HEXP ] Physics [physics]/High Energy Physics - Experiment [hep-ex]RIGHT-HANDED NEUTRINOS0103 physical sciencesAstronomical And Space Sciencesnumerical calculationsDark matter experimentXMM-NEWTON OBSERVATIONSneutrino: modelParticle Physics - PhenomenologyDWARF SPHEROIDAL GALAXYCosmologia010308 nuclear & particles physicshep-exdark matter experimentsHigh Energy Physics::PhenomenologyAstronomy and AstrophysicsAtomic Molecular Nuclear Particle And Plasma PhysicsCosmological neutrinoAstrophysics - Astrophysics of Galaxies13. Climate actionAstrophysics of Galaxies (astro-ph.GA)[PHYS.HPHE]Physics [physics]/High Energy Physics - Phenomenology [hep-ph]Particle physics - cosmology connection[ PHYS.HPHE ] Physics [physics]/High Energy Physics - Phenomenology [hep-ph]High Energy Physics::Experimentneutrino: oscillation[PHYS.ASTR]Physics [physics]/Astrophysics [astro-ph]Journal of Cosmology and Astroparticle Physics
researchProduct

Gibbs-ensemble path-integral Monte Carlo simulations of a mixed quantum-classical fluid

1995

We study a model fluid with classical translational degrees of freedom and internal quantum states in two spatial dimensions. The path-integral Monte Carlo and the Gibbs-ensemble Monte Carlo techniques are combined to investigate the liquid-gas coexistence region in this mixed quantum-classical system. A comparison with the phase diagram obtained in the canonical ensemble is also presented.

PhysicsHybrid Monte CarloQuantum Monte CarloMonte Carlo methodDynamic Monte Carlo methodMonte Carlo method in statistical physicsMonte Carlo integrationStatistical physicsPath integral Monte CarloMonte Carlo molecular modelingPhysical Review E
researchProduct

Direct high-precision mass measurements onAm241,243,Pu244, andCf249

2014

The absolute masses of four long-lived transuranium nuclides, $^{241,243}\mathrm{Am}$, $^{244}\mathrm{Pu}$, $^{244}\mathrm{Pu}$, and $^{249}\mathrm{Cf}$, in the vicinity of the deformed $N=152$ neutron shell closure have been measured directly with the Penning-trap mass spectrometer TRIGA-TRAP. Our measurements confirm the AME2012 mass values of $^{241,243}\mathrm{Am}$ and $^{244}\mathrm{Pu}$ within one standard deviation, which were indirectly determined, by decay spectroscopy studies. In the case of the $^{249}\mathrm{Cf}$ mass, a discrepancy of more than three standard deviations has been observed, affecting absolute masses even in the superheavy element region. The implementation of the…

PhysicsNuclear and High Energy Physics010308 nuclear & particles physics0103 physical sciencesNeutronDecay chainNuclideReduced massAtomic physics010306 general physicsSpectroscopyMass spectrometry01 natural sciencesPhysical Review C
researchProduct

Simulation studies of the laser ablation ion source at the SHIPTRAP setup

2020

Hyperfine interactions 241(1), 46 (2020). doi:10.1007/s10751-020-01708-0

Nuclear and High Energy PhysicsSpeichertechnik - Abteilung BlaumMaterials scienceMultiphysicsNuclear engineeringPenning trapsMass spectrometry01 natural sciences530IonPhysics::Plasma Physics0103 physical sciencesSample preparationddc:530Physical and Theoretical Chemistry010306 general physicsSurface ionization ion sourceLaser ablationMass spectrometry010308 nuclear & particles physicsLaser ablation ion sourceCondensed Matter PhysicsAtomic and Molecular Physics and OpticsIon sourceThermalisationQuadrupole
researchProduct

Increase in transmitted resistance to non-nucleoside reverse transcriptase inhibitors among newly diagnosed HIV-1 infections in Europe

2014

Background: One out of ten newly diagnosed patients in Europe was infected with a virus carrying a drug resistant mutation. We analysed the patterns over time for transmitted drug resistance mutations (TDRM) using data from the European Spread program.Methods: Clinical, epidemiological and virological data from 4317 patients newly diagnosed with HIV-1 infection between 2002 and 2007 were analysed. Patients were enrolled using a pre-defined sampling strategy.Results: The overall prevalence of TDRM in this period was 8.9% (95% CI: 8.1-9.8). Interestingly, significant changes over time in TDRM caused by the different drug classes were found. Whereas nucleoside resistance mutations remained con…

Malevirus strainResistanceHIV InfectionsDrug resistanceTHERAPYNucleoside Reverse Transcriptase InhibitorANTIRETROVIRAL DRUG-RESISTANCE0302 clinical medicineMedical microbiologyGenotypeMedicine and Health SciencesPrevalenceHIV Infection030212 general & internal medicineUNITED-KINGDOMPhylogeny0303 health sciencesCommunicable diseaseTransmission (medicine)adultvirus mutationUPDATED RECOMMENDATIONSvirus transmission3. Good healthEuropeInfectious Diseasesfemalerisk factorvirus resistanceFemaleNAIVE PATIENTSSOCIETY-USA PANELResearch ArticleHumanAdultmedicine.medical_specialtyGenotypeAnti-HIV AgentsVirusArticle03 medical and health sciencesSDG 3 - Good Health and Well-beingmaleMOLECULAR EPIDEMIOLOGYDrug Resistance Viralmedicineproteinase inhibitorHumansTransmissioncontrolled studyhumanmolecular phylogeny030304 developmental biologynonhumanMUTATIONSbusiness.industryAnti-HIV Agentnucleotide sequencenonnucleoside reverse transcriptase inhibitorHuman immunodeficiency virus 1 infectionVirologymajor clinical studyunindexed sequenceParasitology3121 General medicine internal medicine and other clinical medicineMutationHIV-1business
researchProduct

Correction to: Potentially modifiable factors contributing to outcome from acute respiratory distress syndrome: the LUNG SAFE study (Intensive Care M…

2018

The members of the LUNG SAFE Investigators and the ESICM Trials Group were provided in such a way that they could not be indexed as collaborators on PubMed. The publisher apologizes for this error.

Critical Care and Intensive Care Medicine
researchProduct

Resolved versus confirmed ARDS after 24 h: insights from the LUNG SAFE study

2018

Purpose: To evaluate patients with resolved versus confirmed ARDS, identify subgroups with substantial mortality risk, and to determine the utility of day 2 ARDS reclassification. Methods: Our primary objective, in this secondary LUNG SAFE analysis, was to compare outcome in patients with resolved versus confirmed ARDS after 24 h. Secondary objectives included identifying factors associated with ARDS persistence and mortality, and the utility of day 2 ARDS reclassification. Results: Of 2377 patients fulfilling the ARDS definition on the first day of ARDS (day 1) and receiving invasive mechanical ventilation, 503 (24%) no longer fulfilled the ARDS definition the next day, 52% of whom initial…

MaleARDSmedicine.medical_treatmentlnfectious Diseases and Global Health Radboud Institute for Molecular Life Sciences [Radboudumc 4]ARDS reassessment; ARDS Survival; Berlin criteria ARDS; Persisting ARDS;Critical Care and Intensive Care Medicineassisted ventilation0302 clinical medicineRisk Factors030212 general & internal medicinerisk factor AdultTidal volumecomparative studyeducation.field_of_studyRespiratory Distress SyndromeMortality rateRemission Inductiontidal volumeARDS reassessment; ARDS Survival; Berlin criteria ARDS; Persisting ARDS; Critical Care and Intensive Care MedicineARDS reassessmentartificial ventilationclinical trialimmunosuppressive treatmentadult respiratory distress syndromeMiddle AgedARDS SurvivalMonte Carlo methodmedicine.anatomical_structureclassificationpositive end expiratory pressureCardiologyDisease ProgressionSOFA scoredisease severityFemaleAdultmedicine.medical_specialtyPopulationdisease classificationArticleNO03 medical and health sciencesremissionlength of stayAnesthesiologyInternal medicinemedicinepneumoniaSequential Organ Failure Assessment ScoreHumanshumaneducationAgedMechanical ventilationhospital mortalityLungbusiness.industryRisk Factordisease associationRespiratory Distress Syndrome AdultPersisting ARDSmedicine.diseasemajor clinical studymortalityRespiration Artificialbreathing rate030228 respiratory systemdisease exacerbationBerlin criteria ARDSbusinessIntensive care medicine
researchProduct

Treatment-associated polymorphisms in protease are significantly associated with higher viral load and lower CD4 count in newly diagnosed drug-naive …

2012

Background: The effect of drug resistance transmission on disease progression in the newly infected patient is not well understood. Major drug resistance mutations severely impair viral fitness in a drug free environment, and therefore expected to revert quickly. Compensatory mutations, often already polymorphic in wild-type viruses, do not tend to revert after transmission. While compensatory mutations increase fitness during treatment, their presence may also modulate viral fitness and virulence in absence of therapy and major resistance mutations. We previously designed a modeling technique that quantifies genotypic footprints of in vivo treatment selective pressure, including both drug …

AdultMalelcsh:Immunologic diseases. AllergyAnti-HIV AgentseducationVirulenceHIV InfectionsDrug resistanceBiologySettore MED/42 - Igiene Generale E ApplicataViruspolymorphism03 medical and health sciencesViral ProteinsSDG 3 - Good Health and Well-beingVirologyGenotypeDrug Resistance Viraldrug-naivemedicineHumansProspective Studies030304 developmental biology0303 health sciencesPolymorphism Genetic030306 microbiologyResearchproteaseViral LoadVirologyReverse transcriptase3. Good healthCD4 Lymphocyte CountDrug-naïveInfectious Diseases3121 General medicine internal medicine and other clinical medicineImmunologybiology.proteinHIV-1FemaleAntibodylcsh:RC581-607Viral loadHIV-1 infected patientmedicine.drugPeptide HydrolasesRetrovirology
researchProduct

Limited cross-border infections in patients newly diagnosed with HIV in Europe

2013

Background: International travel plays a role in the spread of HIV-1 across Europe. It is, however, not known whether international travel is more important for spread of the epidemic as compared to endogenous infections within single countries. In this study, phylogenetic associations among HIV of newly diagnosed patients were determined across Europe.Results: Data came from the SPREAD programme which collects samples of newly diagnosed patients that are representative for national HIV epidemics. 4260 pol sequences from 25 European countries and Israel collected in 2002-2007 were included.We identified 457 clusters including 1330 persons (31.2% of all patients). The cluster size ranged bet…

MaleEpidemiologyHuman immunodeficiency virus (HIV)Human immunodeficiency virus 1HIV Infectionsmedicine.disease_causeVirologie généralephylogenySettore MED/42 - Igiene Generale E ApplicataMen who have sex with menEMERGENCE0302 clinical medicineMedicine and Health SciencesMedicineInfection controlCluster Analysis030212 general & internal medicineIsraelPathologie maladies infectieusestravelPhylogeny0303 health sciencesMolecular EpidemiologyTravelTransmission (medicine)articlevirus transmissionIMMUNODEFICIENCY-VIRUS TYPE-13. Good healthPeer reviewEuropefemaleInfectious DiseasesSUBTYPE BDRUG-RESISTANT HIV-1RNA Viralmale homosexualAdultstructural geneMolecular Sequence DataNewly diagnosedClusters03 medical and health sciencesmaleSDG 3 - Good Health and Well-beingMOLECULAR EPIDEMIOLOGYSWITZERLANDVirologygeographic distributionHumansTransmissionIn patienthuman030304 developmental biologynonhumanMolecular epidemiologybusiness.industryResearchhigh risk populationVirologie médicalenucleotide sequenceSequence Analysis DNAHuman immunodeficiency virus 1 infectionVirologymajor clinical studyunindexed sequence3121 General medicine internal medicine and other clinical medicineHIV-1businessEurope HIV-1 Transmission ClustersDemographycluster analysis
researchProduct