0000000000997382
AUTHOR
Matthias Onghena
Perfluoroalkyl substances in Breast milk, infant formula and baby food from Valencian Community (Spain)
Environmental and human exposures to perfluoroalkyl substances (PFASs) are of emerging concern since they are persistent and bioaccumulative. The present study reports PFASs levels in human milk, infant formulas and baby food (dry cereals and pots) from the Valencian Community (Spain) in order to evaluate the infant exposure to these substances through the diet. The results show that perfluorobutanoic acid (PFBA) and perfluorooctanoic acid (PFOA) were in all the samples of the four selected matrices (except PFOA in one sample of dry cereal baby food). Perfluoroheptanoic acid (PFHpA) and perfluorodecanoic acid (PFDA) were also detected in 70% of the breast milk samples. In infant formulas, P…
Analysis of 18 perfluorinated compounds in river waters: Comparison of high performance liquid chromatography–tandem mass spectrometry, ultra-high-performance liquid chromatography–tandem mass spectrometry and capillary liquid chromatography–mass spectrometry
In this work, the performance of ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) and capillary liquid chromatography-mass spectrometry (CLC-MS) has been studied for the analysis of eighteen perfluorinated compounds in water samples. UHPLC-MS/MS and CLC-MS analysis were carried out using a Zorbax C-18 column (50 mm × 2.1 mm, 1.8 μm) and a Zorbax SB-C18 column (150 mm × 0.5 mm, 3.5 μm), respectively, in gradient elution mode with a mobile phase of ammonium formate and methanol. Both techniques were compared with conventional LC-MS/MS in terms of speed, sensitivity, selectivity and resolution. Water samples were extracted by solid phase extraction (SPE). Mea…
Analysis of insecticides in honey by liquid chromatography–ion trap-mass spectrometry: Comparison of different extraction procedures
The feasibility of different extraction procedures was tested and compared for the determination of 12 organophosphorus and carbamates insecticides in honey samples. In this sense, once the samples were pre-treated - essentially dissolved in hot water by stirring - and before they could be analyzed by liquid chromatography-ion trap-second stage mass spectrometry (LC-MS(2)), four different approaches were studied for the extraction step: QuEChERS, solid-phase extraction (SPE), pressurized liquid extraction (PLE) and solid-phase microextraction (SPME). The main aim of this work was to maximise the sensitivity of pesticides and to minimise the presence of interfering compounds in the extract. …