0000000001020746

AUTHOR

Daniel Sanjuan-herráez

showing 2 related works from this author

Bladder cancer recurrence surveillance by urine metabolomics analysis.

2018

AbstractNon Muscle Invasive Bladder Cancer (NMIBC) is among the most frequent malignant cancers worldwide. NMIBC is treated by transurethral resection of the bladder tumor (TURBT) and intravesical therapies, and has the highest recurrence rate among solid tumors. It requires a lifelong patient monitoring based on repeated cystoscopy and urinary cytology, both having drawbacks that include lack of sensitivity and specificity, invasiveness and care costs. We conducted an investigative clinical study to examine changes in the urinary metabolome of NMBIC patients before and after TURBT, as well during the subsequent surveillance period. Adjusting by prior probability of recurrence per risk, dis…

0301 basic medicineOncologyMalemedicine.medical_specialtyUrinary systemlcsh:MedicineUrineArticlelaw.invention03 medical and health sciences0302 clinical medicineMetabolomicsRandomized controlled triallawCytologyInternal medicinemedicineMetabolomeBiomarkers TumorHumansMetabolomicslcsh:ScienceAgedAged 80 and overMultidisciplinaryBladder cancermedicine.diagnostic_testbusiness.industrylcsh:RCystoscopyMiddle Agedmedicine.disease030104 developmental biologyUrinary Bladder Neoplasms030220 oncology & carcinogenesisMetabolomelcsh:QFemalebusinessScientific reports
researchProduct

Monitoring of system conditioning after blank injections in untargeted UPLC-MS metabolomic analysis

2019

AbstractUltra-performance liquid chromatography – mass spectrometry (UPLC-MS) is widely used for untargeted metabolomics in biomedical research. To optimize the quality and precision of UPLC-MS metabolomic analysis, evaluation of blank samples for the elimination of background features is required. Although blanks are usually run either at the beginning or at the end of a sequence of samples, a systematic analysis of their effect of the instrument performance has not been properly documented. Using the analysis of two common bio-fluids (plasma and urine), we describe how the injection of blank samples within a sequence of samples may affect both the chromatographic and MS detection performa…

0301 basic medicinelcsh:MedicineUrineMass spectrometryBlankMass SpectrometryArticlePlasma03 medical and health sciences0302 clinical medicineMetabolomicsHumansMetabolomicslcsh:ScienceChromatography High Pressure LiquidPrincipal Component AnalysisMultidisciplinaryChromatographyChemistrylcsh:RData acquisition030104 developmental biologyUntargeted metabolomicsDetection performanceConditioninglcsh:QUplc ms ms030217 neurology & neurosurgeryScientific Reports
researchProduct