0000000001035390

AUTHOR

S. V. Razin

Gyrotron-driven high current ECR ion source for boron-neutron capture therapy neutron generator

Abstract Boron-neutron capture therapy (BNCT) is a perspective treatment method for radiation resistant tumors. Unfortunately its development is strongly held back by a several physical and medical problems. Neutron sources for BNCT currently are limited to nuclear reactors and accelerators. For wide spread of BNCT investigations more compact and cheap neutron source would be much more preferable. In present paper an approach for compact D–D neutron generator creation based on a high current ECR ion source is suggested. Results on dense proton beams production are presented. A possibility of ion beams formation with current density up to 600 mA/cm 2 is demonstrated. Estimations based on obt…

research product

High current proton beams production at Simple Mirror Ion Source 37

This paper presents the latest results of high current proton beam production at Simple Mirror Ion Source (SMIS) 37 facility at the Institute of Applied Physics (IAP RAS). In this experimental setup, the plasma is created and the electrons are heated by 37.5 GHz gyrotron radiation with power up to 100 kW in a simple mirror trap fulfilling the ECR condition. Latest experiments at SMIS 37 were performed using a single-aperture two-electrode extraction system. Proton beams with currents up to 450 mA at high voltages below 45 kV were obtained. The maximum beam current density was measured to be 600 mA/cm2. A possibility of further improvement through the development of an advanced extraction sy…

research product

First experiments on applying the gasdynamic ECR ion source for negative hydrogen ion production

This article has no abstract. peerReviewed

research product

Efficiency investigation of a negative hydrogen ion beam production with the use of the gasdynamic ECR plasma source

Abstract Negative hydrogen ion sources are of great demand in modern physics as injectors into accelerators and drivers for neutral beam injectors for fusion devices. It has been shown earlier that the use of the gasdynamic ECR discharge provides the opportunity to extract up to 80 mA/cm2 of negative ion current density. We studied experimentally the volumetric negative hydrogen ion production and vacuum ultraviolet emission in a gasdynamic ECR discharge. The high-density plasma was sustained by the pulsed 37 GHz / 100 kW gyrotron radiation in a magnetic configuration consisting of two consecutive simple mirror traps. The future prospects of the volumetric H− source based on the gasdynamic …

research product

Powerful neutron generators based on high current ECR ion sources with gyrotron plasma heating

This article has no abstract. peerReviewed

research product

Neutron generator for BNCT based on high current ECR ion source with gyrotron plasma heating

BNCT development nowadays is constrained by a progress in neutron sources design. Creation of a cheap and compact intense neutron source would significantly simplify trial treatments avoiding use of expensive and complicated nuclear reactors and accelerators. D-D or D-T neutron generator is one of alternative types of such sources for. A so-called high current quasi-gasdynamic ECR ion source with plasma heating by millimeter wave gyrotron radiation is suggested to be used in a scheme of D-D neutron generator in the present work. Ion source of that type was developed in the Institute of Applied Physics of Russian Academy of Sciences (Nizhny Novgorod, Russia). It can produce deuteron ion beam…

research product

New progress of high current gasdynamic ion source (invited).

The experimental and theoretical research carried out at the Institute of Applied Physics resulted in development of a new type of electron cyclotron resonance ion sources (ECRISs)—the gasdynamic ECRIS. The gasdynamic ECRIS features a confinement mechanism in a magnetic trap that is different from Geller’s ECRIS confinement, i.e., the quasi-gasdynamic one similar to that in fusion mirror traps. Experimental studies of gasdynamic ECRIS were performed at Simple Mirror Ion Source (SMIS) 37 facility. The plasma was created by 37.5 and 75 GHz gyrotron radiation with power up to 100 kW. High frequency microwaves allowed to create and sustain plasma with significant density (up to 8 × 1013 cm−3 ) …

research product

Efficiency investigation of a negative hydrogen ion beam production with the use of the gasdynamic ECR plasma source

Negative hydrogen ion sources are of great demand in modern physics as injectors into accelerators and drivers for neutral beam injectors for fusion devices. It has been shown earlier that the use of the gasdynamic ECR discharge provides the opportunity to extract up to 80 mA/cm2 of negative ion current density. We studied experimentally the volumetric negative hydrogen ion production and vacuum ultraviolet emission in a gasdynamic ECR discharge. The high-density plasma was sustained by the pulsed 37 GHz / 100 kW gyrotron radiation in a magnetic configuration consisting of two consecutive simple mirror traps. The future prospects of the volumetric H– source based on the gasdynamic ECR disch…

research product

Gasdynamic ECR ion source for negative ion production

H− ion sources are needed in various areas of accelerator technology, such as beam injection into cyclotrons and storage rings and as a part of neutral beam injectors for plasma heating in experimental facilities studying thermonuclear fusion. It was recently demonstrated that gasdynamic ion source based on ECR discharge in a simple mirror trap is very efficient for proton beam production [1]. Here we use the gasdynamic plasma source as the first stage driver of volumetric negative ion production through dissociative electron attachment (DEA) [2]. Experiments were performed with a pulsed 37 GHz / up to 100 kW gyrotron radiation in a dual-trap magnetic system, which consists of two identical…

research product

High yield neutron generator based on a high-current gasdynamic electron cyclotron resonance ion source

In present paper, an approach for high yield compact D-D neutron generator based on a high current gasdynamic electron cyclotron resonance ion source is suggested. Results on dense pulsed deuteron beam production with current up to 500 mA and current density up to 750 mA/cm2 are demonstrated. Neutron yield from D2O and TiD2 targets was measured in case of its bombardment by pulsed 300 mA Dþ beam with 45 keV energy. Neutron yield density at target surface of 109 s 1 cm2 was detected with a system of two 3 He proportional counters. Estimations based on obtained experimental results show that neutron yield from a high quality TiD2 target bombarded by Dþ beam demonstrated in present work accele…

research product

Status of new developments in the field of high-current gasdynamic ECR ion sources at the IAP RAS

The experimental and theoretical research carried out in the past at the Institute of Applied Physics (IAP RAS) resulted in development of a new type of electron cyclotron resonance ion source (ECRIS) – the gasdynamic ECRIS. The gasdynamic ECRIS features a confinement mechanism in a magnetic trap that is different from Geller’s classical ECRIS confinement i.e. the quasi-gasdynamic one similar to that in fusion mirror traps . Such ion source type has demonstrated good performance producing high current (100-300 mA) multi-charged ion beams with moderate average charge (Z=4-5 for argon) and especially high efficiency for low emittance hydrogen and deuterium beam formation (500 emA current, cur…

research product

High current proton source based on ECR discharge sustained by 37.5 GHz gyrotron radiation

Formation of hydrogen ion beams with high intensity and low transverse emittance is one of the key challenges in accelerator technology. Present work is devoted to experimental investigation of proton beam production from dense plasma (Ne > 1013 cm−3) of an ECR discharge sustained by 37.5 GHz, 100 kW gyrotron radiation at SMIS 37 facility at IAP RAS. The anticipated advantages of the SMIS 37 gasdynamic ion source over the current state-of-the-art proton source technology based on 2.45 GHz hydrogen discharges are described. Experimental result obtained with different extraction configurations i.e. single- and multi-aperture systems are presented. It was demonstrated that ultra bright proton …

research product