0000000001078141

AUTHOR

Tiago Buckup

showing 4 related works from this author

Bioorthogonal red and far-red fluorogenic probes for wash-free live-cell and super-resolution microscopy

2020

AbstractSmall-molecule fluorophores enable the observation of biomolecules in their native context with fluorescence microscopy. Specific labelling via bioorthogonal tetrazine chemistry confers minimal label size and rapid labelling kinetics. At the same time, fluorogenic tetrazine-dye conjugates exhibit efficient quenching of dyes prior to target binding. However, live-cell compatible long-wavelength fluorophores with strong fluorogenicity have been difficult to realize. Here, we report close proximity tetrazine-dye conjugates with minimal distance between tetrazine and fluorophore. Two synthetic routes give access to a series of cell permeable and impermeable dyes including highly fluorog…

chemistry.chemical_compoundFluorescence-lifetime imaging microscopyTetrazineFluorophoreQuenching (fluorescence)chemistrySuper-resolution microscopySTED microscopyContext (language use)Bioorthogonal chemistryCombinatorial chemistry
researchProduct

Femtosecond Raman time-resolved molecular spectroscopy

2004

Abstract The applicability of several femtosecond time resolved non-linear coherent techniques such as Raman induced polarization spectroscopy (RIPS), degenerate four-wave mixing (DFWM) and coherent anti-Stokes Raman spectroscopy (CARS) for molecular spectroscopy is presented. All methods rely on the initial coherent excitation of molecular states producing wavepackets, whose time evolution is then measured. In the case of RIPS and DFWM only pure rotational transitions are involved, whereas in CARS vibrational states can be excited. First the methodology of concentration and temperature measurements using RIPS in gas mixtures involving N2, CO2, O2, and N2O is shown. In addition some applica…

Materials sciencebusiness.industryGeneral EngineeringTime evolutionEnergy Engineering and Power TechnologyMolecular physicssymbols.namesakeOpticsExcited stateFemtosecondsymbolsCoherent anti-Stokes Raman spectroscopyTime-resolved spectroscopyRaman spectroscopybusinessSpectroscopyExcitationComptes Rendus Physique
researchProduct

Bio-orthogonal Red and Far-Red Fluorogenic Probes for Wash-Free Live-Cell and Super-resolution Microscopy

2021

Small-molecule fluorophores enable the observation of biomolecules in their native context with fluorescence microscopy. Specific labeling via bio-orthogonal tetrazine chemistry combines minimal label size with rapid labeling kinetics. At the same time, fluorogenic tetrazine–dye conjugates exhibit efficient quenching of dyes prior to target binding. However, live-cell compatible long-wavelength fluorophores with strong fluorogenicity have been difficult to realize. Here, we report close proximity tetrazine–dye conjugates with minimal distance between tetrazine and the fluorophore. Two synthetic routes give access to a series of cell-permeable and -impermeable dyes including highly fluorogen…

fluorophoreFluorescence-lifetime imaging microscopyFluorophoreQuenching (fluorescence)ChemistrySuper-resolution microscopyGeneral Chemical Engineeringmammalian-cellsSTED microscopyContext (language use)General ChemistryCombinatorial chemistryChemistrychemistry.chemical_compoundTetrazinetetrazine probesFluorescence microscopestrategyQD1-999Research ArticleACS Central Science
researchProduct

Femtosecond Raman time-resolved molecular spectroscopy

2004

International audience; The applicability of several femtosecond time resolved non-linear coherent techniques such as Raman induced polarization spectroscopy (RIPS), degenerate four-wave mixing (DFWM) and coherent anti-Stokes Raman spectroscopy (CARS) for molecular spectroscopy is presented. All methods rely on the initial coherent excitation of molecular states producing wavepackets, whose time evolution is then measured. In the case of RIPS and DFWM only pure rotational transitions are involved, whereas in CARS vibrational states can be excited. First the methodology of concentration and temperature measurements using RIPS in gas mixtures involving N2, CO2, O2, and N2O is shown. In additi…

[PHYS.PHYS.PHYS-OPTICS] Physics [physics]/Physics [physics]/Optics [physics.optics][PHYS.PHYS.PHYS-OPTICS]Physics [physics]/Physics [physics]/Optics [physics.optics]Femtosecond laser; Ultrafast phenomena; Non-linear coherent and time resolved spectroscopy; Rovibrational wavepacket; Thermometry[ PHYS.PHYS.PHYS-OPTICS ] Physics [physics]/Physics [physics]/Optics [physics.optics]
researchProduct