Intraosseous Fixation Compared to Plantar Plate Fixation for First Metatarsocuneiform Arthrodesis
Background: Metatarsocuneiform (MTC) fusion is a treatment option for management of hallux valgus. We compared the biomechanical characteristics of an internal fixation device with plantar plate fixation. Methods: Seven matched pairs of feet from human cadavers were used to compare the intramedullary (IM) device plus compression screw to plantar plate combined with a compression screw. Specimen constructs were loaded in a cyclic 4-point bending test. We obtained initial/final stiffness, maximum load, and number of cycles to failure. Bone mineral density was measured with peripheral quantitative computed tomography. Performance was compared using time to event analysis with number of cycles …