Evaluation of the Spectroscopic Performance of 3D CZT Drift Strip Detectors

CdTe/CZT is an attractive and consolidated material with which to realize detectors with good efficiency and energy resolution, operating at room temperature and suitable for a large variety of applications such as medical imaging, nuclear security, and astrophysics. Right in this last field several spectro-imagers based on these CdTe/CZT detectors were mounted onboard space missions such as INTEGRAL, Swift, and NuSTAR for hard X and gamma-ray astrophysics. Much effort has been expended in the development of CZT spectroscopic imagers for obtaining sub-millimeter spatial resolution in three dimensions (3D) and high energy resolution up to 1 MeV. The motivations are mainly related to the poss…

research product

Mechanically stable metal layers for ohmic and blocking contacts on CdZnTe detectors by electroless deposition

CdZnTe detectors are commonly exploited for the detection of gamma rays. However, obtaining mechanical stable, low noise contacts on CdZnTe is still an issue. In particular, ohmic contacts would be preferable for high flux applications. In this work, we show that it is possible to obtain mechanical stable gold contacts by electroless deposition in methanol solution. Moreover, we show that electroless deposited nickel contacts are also mechanical stable and are good candidates for the realization of ohmic contacts on high resistivity CdZnTe crystals.

research product

Charge loss correction in CZT pixel detectors at low and high fluxes: analysis of positive and negative pulses

Charge losses are typical drawbacks in cadmium–zinc–telluride (CZT) pixel detectors. The effects of these phenomena are strongly related to the interaction point of the photons and are more severe for photon interactions at the inter-pixel gap and near the pixelated anode. In this work, we present some original techniques able to correct charge losses in pixelated CZT detectors at both low and high fluxes. The height, the shape and the arrival time of collected- and induced-charge pulses with both positive and negative polarities are analysed to recover charge losses after the application of charge sharing addition (CSA). Sub-millimetre CZT pixel detectors, fabricated by different manufactu…

research product

High Bias Voltage CZT Detectors for High-flux Measurements

In this work, we present the performance of new travelling heater method (THM) grown CZT detectors, recently developed at IMEM-CNR Parma, Italy. Thick planar detectors (3 mm thick) with gold electroless contacts on CZT crystals grown by Redlen Technologies (Victoria BC, Canada) were realized, with a planar cathode covering the detector surface (4.1 x 4.1 mm(2)) and a central anode (2 x 2 mm(2)) surrounded by a guard ring electrode. The detectors, characterized by low leakage currents at room temperature (4.7 nA/cm(2) at 1000 V/cm), allow good room temperature operation even at high bias voltages (> 7000 V/cm). At low rates, the detectors exhibit an energy resolution around 4 % FWIEM at 59.5…

research product

Digital CZT detector system for high flux energy-resolved X-ray imaging

Photon counting arrays with energy resolving capabilities are recently desired for the next-generation X-ray imaging systems. In this work, we present the performance of a 2 mm thick CZT pixel detector, with pixel pitches of 500 mu m and 250 mu m, coupled to a fast and low noise ASIC (PIXIE ASIC), characterized by only the preamplifier stage. A 16-channel digital readout electronics was used to continuously digitize and process each output channel from the PIXIE ASIC, performing multi-parameter analysis (event arrival time, pulse shape, pulse height) at low and high input counting rates (ICRs). The spectroscopic response of the system to monochromatic X-ray and gamma ray sources, at both lo…

research product

A CZT 3D imaging spectrometer prototype with digital readout for high energy astronomy

The scientific challenges still open in hard X-rays and γ-rays astronomy require the development of new instrumentation able to overcome the sensitivity limits of the present one. Among the technologies currently under study to cover the energy range between several tens of keV and one MeV, the development of telescopes equipped with broadband Laue lenses associated with focal planes with high spectroscopic and imaging performance represents an extremely promising solution. With this perspective, we report on the development and the first spectroscopic characterisation results of an X/γ rays detection system (10-1000 keV) based on CZT spectrometers with spatial resolution in three dimension…

research product

Monte Carlo evaluation of a CZT 3D spectrometer suitable for a Hard X- and soft-γ rays polarimetry balloon borne experiment

Today, the measurement of the polarization status of cosmic sources high-energy' emission, is recognized as a key observational parameter to understand the active production mechanism and its geometry. Therefore, a mandatory requirement for new instrumentations operating in this energ.-y range will be to provide high sensitivity for polarimetric measurements. In this framework, we have presented the concept of a small high-performance imaging spectrometer optimized for polarimetry between 100 and 600 keV suitable for a stratospheric balloon-borne payload and as a pathfinder for a future satellite mission. The detector with 3D spatial resolution is based on a CZT spectrometer in a highly seg…

research product

Charge carrier transport mechanisms in CdZnTe detectors grown by the vertical Bridgman technique

In this work, we report on the results of electrical characterization of CdZnTe (CZT) detectors, with gold electroless contacts, grown by the boron oxide encapsulated vertical Bridgman technique (B-VB), currently produced at IMEM-CNR (Parma, Italy). The detectors, with different thicknesses (1 and 2.5 mm), have the same electrode layout: the anode is a central electrode (2 x 2 mm(2)) surrounded by a guard ring electrode. The cathode is a planar electrode covering the detector surface (4.1 x 4.1 mm(2)). Current-voltage (I-V) characteristics were measured at different temperatures in order to study the charge transport and the electrical properties. These detectors were compared with the trav…

research product

Spectroscopic response and charge transport properties of CdZnTe detectors grown by the vertical Bridgman technique

In this work, we present the results of spectroscopic investigations on CdZnTe (CZT) detectors grown by the boron oxide encapsulated vertical Bridgman technique (1MEM-CNR, Parma, Italy). The detectors, with different thicknesses (1 and 2.5 mm), are characterized by the same electrode layout (gold electroless contacts): the anode is a central electrode (2 x 2 mm(2)) surrounded by a guard-ring electrode, while the cathode is a planar electrode covering the detector surface (4.1 x 4.1 mm(2)). The results of electrical investigations point out the low leakage currents of these detectors even at high bias voltages: 38 nA/cm(2) (T = 25 degrees C) at 10000 V/cm. The time stability and the spectros…

research product

A 3D CZT hard x-ray polarimeter for a balloon borne payload

Currently, it is widely recognised that a measurement of the polarization status of cosmic sources high energy emission is a key observational parameter to understand the active production mechanism and its geometry. Therefore new instrumentation operating in this energy range should be optimized also for this type of measurement. In this framework, we present the concept of a small high-performance spectrometer designed for polarimetry between 100 and 500 keV suitable as a stratospheric balloon-borne payload dedicated to perform an accurate and reliable measurement of the polarization status of the Crab pulsar, i.e. the polarization level and direction. The detector with 3D spatial resolut…

research product

High performance 3D CZT spectro-imager for BNCT-SPECT: preliminary characterization

The National Institute of Nuclear Physics (INFN) is supporting the 3CaTS project with the aim of developing a new Single Photon Emission Computed Tomography (SPECT) system for real time 10 B therapeutic dose monitoring in the binary experimental hadron therapy called Boron Neutron Capture Therapy (BNCT). BNCT is a highly selective tumour treatment based on the neutron capture reaction 10 B(n,α) 7 Li. The secondary particles have a high LET with ranges in tissues of the order of 10 μm (thus less than the mean cell diameter of few tens μm). Targeting the 10 B delivery towards cancer, the released energy lethally damages only the malignant cells sparing the normal tissues, thus enabling a cell…

research product

New Results on High-Resolution 3-D CZT Drift Strip Detectors

Intense research activities have been carry out in the development of room temperature gamma ray spectroscopic imagers, aiming to compete with the excellent energy resolution of high-purity germanium (HPGe) detectors (0.3 % FWHM at 662 keV) obtained after cryogenic cooling. Cadmium-zinc-telluride (CZT) detectors equipped with pixel, strip and virtual Frisch-grid electrode structures represented an appealing solution for room temperature measurements. In this work, we present the performance of new high-resolution CZT drift strip detectors (19.4 x 19.4 x 6 mm3), recently fabricated at IMEM-CNR of Parma (Italy) in collaboration with due2lab company (Reggio Emilia, Italy). The detectors, worki…

research product

Recent trends in the development of CdTe and CdZnTe semiconductor detectors for astrophysical applications

Cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) offer great promise as x-ray and gamma ray detectors. Due to the high detection efficiency, the good room temperature performance and the recent improvements on crystal growth technology, CdTe and CdZnTe detectors have obtained an increasing interest in the field of hard x-ray and gamma ray astronomy. In this paper, we report on the R&D activities on CdTe and CdZnTe detectors for high energy space instrumentation. Our group has been involved in the design of new multilayer hard x and soft gamma ray Laue lens telescopes and, in particular on the development of focal plane detectors based on CdTe and CdZnTe. Here we present the acti…

research product

HARD X-RAY CZT DETECTOR DEVELOPMENT AND TESTING ON STRATOSPHERIC BALLOON PAYLOADS

We report on the R&D activities on the development of room temperature semiconductor detectors (CZT detectors) for high energy space instrumentation. Our groups have been involved in the development of new hard X and soft gamma ray telescopes (e.g. Laue lens telescopes) and focal plane detectors. We present the characteristics and the performance of various CZT detector prototypes coupled with custom read-out electronics. The main target of this R&D activity is an end to end system for domestic growth CZT crystals, new sensor configurations and related read out architecture to provide an effective 3D focal plane able to perform contemporaneously imaging (spatial resolution mm or better), ti…

research product

High-Resolution 3-D CZT Drift Strip Detectors for Prompt Gamma Ray and Neutron Detection in BNCT

Spectroscopic imagers based on high-Z and wide-bandgap compound semiconductor detectors are widely proposed for the detection of prompt gamma rays in boron neutron capture therapy (BNCT). BNCT is a therapy based on the neutron capture reaction 10B (n,α)7Li. To perform a real-time monitoring of the spatial distribution of 10B during the treatments, the detection of the prompt gamma rays (478 keV), produced by the 7Li recoil nuclei, can be helpful. In this work, we presented the potentialities of new high-resolution CZT drift strip detectors, recently developed by our group, for BNCT measurements. The detectors, exploiting the analysis of the collected-induced charge pulses from anodes, catho…