0000000001082449
AUTHOR
Jean-pierre Gonnet
Systematic Error Correction of a 3D Laser Scanning Measurement Device
International audience; Non-contact measurement techniques using laser scanning have the advantage of fast acquiring large numbers of points. However, compared to their contact-based counterparts, these techniques are known to be less accurate. The work presented in this paper aims at improving the accuracy of these techniques through an error correction procedure based on an experimental process that concerns mechanical parts. The influence of the three parameters defining the relative position and the orientation between the sensor and the surface is studied. The process used to build an experimental global model of error is presented and applied to a typical part composed of planes or sk…
Analyse de la mesure des pièces 3D complexes
International audience
Parameters analysis influencing 3D measurement without contact by laser scanner to establish a local correction procedure
International audience; The techniques of measuring without contact by laser scanning allows acquisition of a large number of points, at a very high rate speed ; nevertheless with less precision than the one obtained by classical techniques of measuring with contact. We present in this article the research and the experimental analysis of the influential parameters on the precision of the measure by laser sensor without contact. Firstly, a methodology of correction of the relative uncertainties in the conditions of the measuring laser is presented. Then, we apply it to a typical part and compare the results to those obtained by a classical procedure of measuring with a contact sensor. We fi…
Systematic Error Correction of a 3D laser scanning Measurement Device
International audience
Taking digitized points quality into account in geometrical specification measurement by laser sensor
International audience; Today, the new measurement techniques without contact like the laser sensors are used more and more in industrial applications. They allow to obtain many points in a short time. However these techniques have a less good accuracy than the classical process with contact probe for metrology application. The work presented in this paper, is part of a research project on the in-process product inspection. In the case of in-process product inspection, the throughput time must be the shortest with a good dimensional accuracy. So, it is necessary to increase the measurement accuracy of the points cloud for using the laser scanners. For this first approach, we suggest to buil…
Path Planning in Inspection Process of 3-D Parts Used the Visibility Technique
International audience; In this paper presents a new method for digitalization of parts with non-contact sensor remains nevertheless complex. It is not completely solved today, in particular from a metrological point of view. In this article, we consider the determination of the trajectory planning within the framework of the control of dimensional and geometrical specifications. The sensor used in this application is a laser planner scanner with CCD camera oriented and moved by a CMM. Thus, we seek to determine which are the best possible orientations of the sensor with respect to the geometrical specifications of the measured part, giving the admissible measurement uncertainties. The deve…