0000000001091110

AUTHOR

Frédérique Frouin

showing 10 related works from this author

Impact of 7-Ketocholesterol and Very Long Chain Fatty Acids on Oligodendrocyte Lipid Membrane Organization: Evaluation Via LAURDAN and FAMIS Spectral…

2011

International audience; In the context of multiple sclerosis and X-linked adrenoleukodystrophy, 7-ketocholesterol (7KC) and very long chain fatty acids (C24:0, C26:0) are supposed to induce side effects respectively on oligodendrocytes which are myelin (which is a lipoproteic complex) synthesizing cells. The effects of 7KC (25, 50 mu M), C24:0 and C26:0 (10, 20 mu M) on cell viability and lipid membrane organization were investigated on 158N murine oligodendrocytes. Concerning 7KC and fatty acids (at 20 mu M only):1) cell growth was strongly inhibited; 2) marked induction of cell death was revealed with propidium iodide (PI); 3) no apoptotic cells were found with C24:0 and C26:0 (absence of…

MaleMYELINlaw.inventionchemistry.chemical_compoundMice0302 clinical medicinelawFAMIS2-Naphthylamine[SDV.IDA]Life Sciences [q-bio]/Food engineeringEnzyme InhibitorsLipid bilayerKetocholesterols0303 health sciencesMicroscopy ConfocalOXYSTEROLSFatty AcidsMULTIPLE-SCLEROSISvery long chain fatty acidsCell biologyPEROXISOMAL DISORDERSAPOPTOSISOligodendrogliaX-LINKED ADRENOLEUKODYSTROPHYmedicine.anatomical_structureMembraneCHOLESTEROL OXIDESlipids (amino acids peptides and proteins)Laurdanalpha-CyclodextrinsHistologyContext (language use)BiologyMETABOLISMPathology and Forensic Medicine158N oligodendrocytes03 medical and health sciencesMembrane LipidsConfocal microscopymedicineAnimals[SPI.GPROC]Engineering Sciences [physics]/Chemical and Process EngineeringViability assayPropidium iodideLAURDAN7-ketocholesterol030304 developmental biologyFluorescent DyesCell MembraneCENTRAL-NERVOUS-SYSTEMCell BiologyOligodendrocytechemistryCELLSmono-photon confocal microscopy030217 neurology & neurosurgeryLaurates
researchProduct

Improved estimation of the left ventricular ejection fraction using a combination of independent automated segmentation results in cardiovascular mag…

2014

—This work aimed at combining different segmenta-tion approaches to produce a robust and accurate segmentation result. Three to five segmentation results of the left ventricle were combined using the STAPLE algorithm and the reliability of the resulting segmentation was evaluated in comparison with the result of each individual segmentation method. This comparison was performed using a supervised approach based on a reference method. Then, we used an unsupervised statistical evaluation, the extended Regression Without Truth (eRWT) that ranks different methods according to their accuracy in estimating a specific biomarker in a population. The segmentation accuracy was evaluated by focusing o…

[SDV.IB.IMA] Life Sciences [q-bio]/Bioengineering/Imaging[SDV.MHEP.CSC]Life Sciences [q-bio]/Human health and pathology/Cardiology and cardiovascular system[SDV.IB.IMA]Life Sciences [q-bio]/Bioengineering/Imaging[ SPI.SIGNAL ] Engineering Sciences [physics]/Signal and Image processing[ SDV.MHEP.CSC ] Life Sciences [q-bio]/Human health and pathology/Cardiology and cardiovascular system[SPI.SIGNAL]Engineering Sciences [physics]/Signal and Image processing[ SDV.IB.IMA ] Life Sciences [q-bio]/Bioengineering/Imaging[SPI.SIGNAL] Engineering Sciences [physics]/Signal and Image processing[SDV.MHEP.CSC] Life Sciences [q-bio]/Human health and pathology/Cardiology and cardiovascular system
researchProduct

Effects of caspase inhibitors (z-VAD-fmk, z-VDVAD-fmk) on Nile Red fluorescence pattern in 7-ketocholesterol-treated cells: Investigation by flow cyt…

2007

Background: The 7-ketocholesterol (7KC)-induced cell death has some characteristics of apoptosis and is associated with polar lipid accumulation. So, we investigated the effects of the broad-spectrum caspase inhibitor z-VAD-fmk and of the caspase-2 inhibitor z-VDVAD-fmk on lipid profile evaluated by staining with Nile Red (NR). Methods: The 7KC-treated human monocytic U937 cells were cultured in the absence or in the presence of the caspase inhibitors z-VAD-fmk or z-VDVAD-fmk. When staining with NR is performed, neutral and polar lipids have yellow and orange/red emission, respectively, and fluorescence was then analyzed by flow cytometry (FCM) and by confocal laser scanning microscopy (CLS…

HistologyConfocalCaspase 2FluorescencePathology and Forensic Medicinelaw.inventionFlow cytometryAmino Acid Chloromethyl Ketones03 medical and health scienceschemistry.chemical_compound0302 clinical medicineConfocal microscopylawOxazinesmedicineImage Processing Computer-AssistedHumans[ SDV.IB ] Life Sciences [q-bio]/BioengineeringEnzyme InhibitorsKetocholesterols030304 developmental biology[SDV.IB] Life Sciences [q-bio]/BioengineeringCell Nucleus0303 health sciencesMicroscopyMicroscopy Confocalbiologymedicine.diagnostic_testNile redLipid metabolismCell BiologyU937 CellsFlow CytometryLipid MetabolismFluorescenceMolecular biologyCaspase Inhibitors3. Good healthStainingchemistry030220 oncology & carcinogenesisbiology.protein[SDV.IB]Life Sciences [q-bio]/Bioengineeringbiological phenomena cell phenomena and immunityFactor Analysis Statistical
researchProduct

Analysis of fluorescent MRI contrast agent behavior in the liver and thoracic aorta of mice.

2004

To characterize the behavior of magnetofluorescent products injected in mice intravenously.The magnetic resonance imaging (MRI) products were labelled with fluorescent molecules to examine the biodistribution process in vivo and observe them at the cellular level by means of confocal microscopy. Three-dimensional (3D) sequences of images were obtained by spectral analysis of sample preparations in a multiphoton confocal microscope and analyzed by the factor analysis of medical image sequence algorithm, which provides factor curves. Factor images are the result of image-processing methods that utilize information from emission spectra. Preparations are also screened in the counting mode to p…

[SDV.IB.IMA]Life Sciences [q-bio]/Bioengineering/ImagingContrast MediaAorta ThoracicMiceMESH : Image CytometryMESH: Microscopy ConfocalMESH : FemaleMESH : Fluorescent DyesMESH: AnimalsMESH : Algorithms[ SDV.IB.IMA ] Life Sciences [q-bio]/Bioengineering/Imaginghealth care economics and organizationsImage CytometryMice Inbred BALB CMicroscopy ConfocalMESH: Fluorescent DyesMESH: Staining and LabelingLiverMESH : MeglumineFemaleMESH : Organometallic CompoundsAlgorithmsMESH: Aorta ThoraciceducationMESH: Mice Inbred BALB CMESH: AlgorithmsMESH: MeglumineMESH : Staining and LabelingMeglumineMESH: Contrast MediaMESH : MiceOrganometallic CompoundsAnimalsMESH : Microscopy ConfocalMESH: MiceMESH : Mice Inbred BALB CFluorescent DyesMESH : Aorta ThoracicMESH : Contrast MediaStaining and LabelingMESH : LiverMESH: Organometallic CompoundsMESH : Xanthenes[SDV.IB.IMA] Life Sciences [q-bio]/Bioengineering/ImagingXanthenesMESH: XanthenesMESH : AnimalsMESH: FemaleMESH: Image CytometryMESH: Liver
researchProduct

Definition of a mutual reference shape based on information theory and active contours

2013

In this paper, we propose to consider the estimation of a reference shape from a set of different segmentation results using both active contours and information theory. The reference shape is then defined as the minimum of a criterion that benefits from both the mutual information and the joint entropy of the input segmentations. This energy criterion is here justified using similarities between information theory quantities and area measures, and presented in a continuous variational framework. This framework brings out some interesting evaluation measures such as the specificity and sensitivity. In order to solve this shape optimization problem, shape derivatives are computed for each te…

[ INFO.INFO-TS ] Computer Science [cs]/Signal and Image Processingsegmentation evaluation[ INFO.INFO-IM ] Computer Science [cs]/Medical Imaging[INFO.INFO-TS] Computer Science [cs]/Signal and Image Processingaverage shape[SDV.IB.IMA]Life Sciences [q-bio]/Bioengineering/Imaging[INFO.INFO-IM] Computer Science [cs]/Medical ImagingComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISION[ SPI.SIGNAL ] Engineering Sciences [physics]/Signal and Image processingactive contours[SDV.IB.IMA] Life Sciences [q-bio]/Bioengineering/Imaging[INFO.INFO-TI] Computer Science [cs]/Image Processing [eess.IV]shape gradientsImage processingcardiac MRI.[INFO.INFO-TS]Computer Science [cs]/Signal and Image Processing[INFO.INFO-TI]Computer Science [cs]/Image Processing [eess.IV][ INFO.INFO-TI ] Computer Science [cs]/Image Processingshape optimizationcardiac MRI[INFO.INFO-IM]Computer Science [cs]/Medical Imaging[SPI.SIGNAL]Engineering Sciences [physics]/Signal and Image processing[ SDV.IB.IMA ] Life Sciences [q-bio]/Bioengineering/Imaging[SPI.SIGNAL] Engineering Sciences [physics]/Signal and Image processinginformation theory
researchProduct

Comparison of different segmentation approaches without using gold standard. Application to the estimation of the left ventricle ejection fraction fr…

2011

International audience; A statistical method is proposed to compare several estimates of a relevant clinical parameter when no gold standard is available. The method is illustrated by considering the left ventricle ejection fraction derived from cardiac magnetic resonance images and computed using seven approaches with different degrees of automation. The proposed method did not use any a priori regarding with the reliability of each method and its degree of automation. The results showed that the most accurate estimates of the ejection fraction were obtained using manual segmentations, followed by the semiautomatic methods, while the methods with the least user input yielded the least accu…

MESH : Ventricular Function Left[ INFO.INFO-TS ] Computer Science [cs]/Signal and Image Processing[INFO.INFO-TS] Computer Science [cs]/Signal and Image Processing[ SPI.SIGNAL ] Engineering Sciences [physics]/Signal and Image processing02 engineering and technologyMESH: Regression AnalysisVentricular Function LeftArticleMESH: Ventricular Function Left030218 nuclear medicine & medical imagingMESH: Magnetic Resonance Imaging03 medical and health sciencesMESH : Heart0302 clinical medicine[INFO.INFO-TS]Computer Science [cs]/Signal and Image ProcessingMESH : Magnetic Resonance ImagingMESH : Regression Analysis0202 electrical engineering electronic engineering information engineeringHumansMedicineSegmentation[ SDV.IB ] Life Sciences [q-bio]/BioengineeringReliability (statistics)[SPI.SIGNAL] Engineering Sciences [physics]/Signal and Image processing[SDV.IB] Life Sciences [q-bio]/BioengineeringEjection fractionMESH: Humansbusiness.industryMESH : HumansHeartRegression analysisPattern recognitionImage segmentationGold standard (test)Magnetic Resonance ImagingMESH: Heartmedicine.anatomical_structureVentricleRegression AnalysisA priori and a posteriori020201 artificial intelligence & image processing[SDV.IB]Life Sciences [q-bio]/BioengineeringArtificial intelligencebusinessNuclear medicine[SPI.SIGNAL]Engineering Sciences [physics]/Signal and Image processing
researchProduct

A reference free approach for the comparative evaluation of eight segmentation methods for the estimation of the left ventricular ejection fraction i…

2012

International audience; Objective evaluation and comparison of segmentation algorithms for medical imaging is still a challenging issue. The most frequently used evaluation method consists in comparing the segmentation with a manual delineation. Since obtaining such manual segmentation can be tedious, we proposed a method based on the "extended Regression Without Truth" approach (eRWT)(1). This approach is applied to the comparative evaluation of 8 segmentation algorithms with different degrees of automation from the estimated left ventricular ejection fraction (LVEF).

[INFO.INFO-TI] Computer Science [cs]/Image Processing [eess.IV][ INFO.INFO-IM ] Computer Science [cs]/Medical Imaging[INFO.INFO-TI]Computer Science [cs]/Image Processing [eess.IV][ INFO.INFO-TI ] Computer Science [cs]/Image Processing[INFO.INFO-IM] Computer Science [cs]/Medical Imaging[INFO.INFO-IM]Computer Science [cs]/Medical Imaging
researchProduct

Flow cytometry and spectral imaging multiphoton microscopy analysis of CD36 expression with quantum dots 605 of untreated and 7-ketocholesterol-treat…

2006

To evaluate CD36 expression with quantum dots 605 (QDs 605) on untreated and 7-ketocholesterol (7KC)-treated monocytic U937 cells by flow cytometry (FCM) and confocal and multiphoton laser scanning microscopy (CLSM).Cells were analyzed by CLSM, following flow cytometric quantification of CD36 expression and 7KC uptake. Image sequences were obtained by spectral analysis in monophoton and multiphoton CLSM and analyzed by the factor analysis of medical image sequences (FAMIS) algorithm to differentiate emission spectra. In CLSM analysis, cell deposits were screened in ultraviolet excitation modes to optimize the possibilities of QDs 605 and have the benefit of nuclei counterstaining by DAPI.FC…

CD36 AntigensMESH: PhotonsMESH : Flow CytometryMESH: AlgorithmsMESH: Flow CytometryMESH: U937 CellsMESH : Quantum DotsMESH: MonocytesMonocytesMESH : Microscopy Fluorescence MultiphotonMESH : PhotonsQuantum DotsMESH : Cells Cultured[SDV.BBM] Life Sciences [q-bio]/Biochemistry Molecular BiologyHumans[SDV.BBM]Life Sciences [q-bio]/Biochemistry Molecular BiologyKetocholesterols[ SDV.BBM ] Life Sciences [q-bio]/Biochemistry Molecular BiologyCells CulturedMESH : AlgorithmsMESH : KetocholesterolsPhotonsMESH: HumansMESH: Antigens CD36MESH : HumansMESH: KetocholesterolsU937 CellsMESH: Quantum DotsFlow CytometryMESH : Antigens CD36Microscopy Fluorescence MultiphotonMESH : MonocytesMESH : U937 CellsMESH: Microscopy Fluorescence MultiphotonAlgorithmsMESH: Cells Cultured
researchProduct

FRET multiphoton spectral imaging microscopy of 7-ketocholesterol and Nile Red in U937 monocytic cells loaded with 7-ketocholesterol.

2004

To show the effect of 7-ketocholesterol (7KC) on cellular lipid content by means of flow cytometry and the interaction of 7KC with Nile Red (NR) via ultraviolet fluorescence resonance energy transfer (FRET) excitation of NR on U937 monocytic cells by means of 2-photon excitation confocal laser scanning microscopy (CLSM).Untreated and 7KC-treated U937 cells were stained with NR and analyzed by flow cytometry and CLSM. 3D sequences of images were obtained by spectral analysis in a 2-photon excitation CLSM and analyzed by the factor analysis of medical image sequences (FAMIS) algorithm, which provides factor curves and images. Factor images are the result of the FAMIS image processing method, …

MESH: Cell DeathMESH: Fluorescence Resonance Energy TransferMESH: Mitochondria[SDV.IB.IMA]Life Sciences [q-bio]/Bioengineering/ImagingMESH : Flow CytometryMESH: Flow CytometryMESH: U937 CellsMESH: MonocytesMonocytesMembrane PotentialsMESH : Staining and LabelingMESH : Microscopy Fluorescence MultiphotonOxazinesFluorescence Resonance Energy TransferImage Processing Computer-AssistedHumansMESH: Membrane PotentialsMESH: Microscopy ConfocalMESH : Membrane PotentialsMESH : Fluorescent DyesMESH : Microscopy ConfocalKetocholesterols[ SDV.IB.IMA ] Life Sciences [q-bio]/Bioengineering/ImagingFluorescent DyesMESH : KetocholesterolsMicroscopy ConfocalMESH: HumansMESH : OxazinesCell DeathStaining and LabelingMESH : HumansMESH: KetocholesterolsU937 CellsFlow CytometryMESH: Fluorescent DyesMESH: Image Processing Computer-AssistedMitochondriaMESH: Staining and Labeling[SDV.IB.IMA] Life Sciences [q-bio]/Bioengineering/ImagingMicroscopy Fluorescence MultiphotonMESH : MonocytesMESH : Fluorescence Resonance Energy TransferMESH : Cell DeathMESH : U937 CellsMESH: Microscopy Fluorescence MultiphotonMESH : MitochondriaMESH: OxazinesMESH : Image Processing Computer-Assisted
researchProduct

Evaluation of cardiac structure segmentation in cine magnetic resonance imaging

2015

International audience

[ INFO.INFO-IM ] Computer Science [cs]/Medical Imaging[INFO.INFO-IM] Computer Science [cs]/Medical Imaging[INFO.INFO-IM]Computer Science [cs]/Medical ImagingComputingMilieux_MISCELLANEOUS
researchProduct