12C ion beam dose distribution in presence of medium inhomogeneities: comparison between different measurements and simulations with the treatment pl…

2012

Heavy-ions beams offer several advantages compared to other radiation such as low lateral scattering and high biological effectiveness (RBE) in the Bragg peak region, making them particularly attractive for the treatment of radio-resistant tumours localized close to organs at risk [1]. The extension of ion therapy to new clinical cases requires the exploitation of a dedicated treatment planning system (TPS) based on the existing version of TRiP98 [2,3], established TPS for carbon ions. The theoretical models and experimental databases included in TRiP98 are presently mainly based on measurements in water. This approximation can be applied successfully to reproduce many biological tissues wi…

ion therapyESR and TL dosimetry for treatment planning systemSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Characterization of alanine EPR detectors response in clinical carbon ion beams

2012

Heavy-ions beams offer several advantages compared to other radiation such as low lateral scattering and high biological effectiveness (RBE) in the Bragg peak region, making them particularly attractive for the treatment of radio-resistant tumors localized close to organs at risk [1]. Although ion beam radiotherapy ultimately requires dose prescription in terms of biological dose or cell survival, absorbed dose is still the quantity mostly used in clinical quality assurance and to dosimetrically characterize the beam. Moreover, the nuclear projectile fragmentation of heavy ions because of inelastic nuclear interactions with medium produces secondary particles with lower Z. The detailed know…

alanine EPR dosimeterscarbon ion beamsSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Alanine EPR pellets for dosimetry of clinical proton and carbon ion beams

2015

The main gol of the present work is to investigate the response behaviour of alanine EPR pellets in clinical proton anc carbon ion beams. Proton irradiations were carried out at PSI (Switzerland) using both passive and active scattering modality, whereas, C ions irradiation were performed at GSI (Germany) adopting the raster scanning modality.

Alanine Protons Carbon Ions SOBPLEM LETSettore FIS/01 - Fisica SperimentaleSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)