0000000001114956
AUTHOR
M. Aiello
A low cost and easy re-configurable instrument for power quality survey
In this document the development of a low cost and user friendly PC-based instrument for power quality measurement is proposed, according to IEC 61000-4-7 and standard IEC 61000-4-30. It is an easily re-configurable instrument able to measure harmonics, interharmonics and amplitude disturbances and supply unbalance. In order to verify its accuracy, the instrument has been tested according standard test procedures, by means of a built-up calibration test bench.
A PC-based instrument for harmonics and interharmonics measurement in power supply systems
Abstract Growing interest on power quality has led international working groups to define new standards for testing and measurement techniques to apply to power systems. Special attention has been paid to harmonic and interharmonic measurements. Here, the authors introduce a PC-based instrument capable of synchronising sampling frequency with fundamental frequency in order to perform on-line voltage or current distortion analysis. The instrument has been developed in accordance with currently available standards and international documents, IEC 61000-4-7 Ed. 2002, IEC 61000-4-30 Ed. 2003, Draft Guide IEEE P1159.1 Ed. 2003 and limits given by IEC 61000 Part. 3. A detailed description of the …
Synchronization techniques for power quality instruments
The measurement of voltage characteristics in power systems requires the accurate estimation of the power supply frequency and signal synchronization, even in the presence of disturbances. The authors developed and tested two innovative techniques for instrument synchronization. The first is based on signal spectral analysis techniques performed by means of the Chirp-Z transform analysis. The second is a phase-locked loop (PLL) software based on a time-domain coordinate transformation and an innovative phase-detection technique. To evaluate how synchronization techniques are adversely affected by the application of a disturbing influence, experimental tests were carried out, taking into acc…
An induction motor speed measurement based on current harmonic analysis with Chirp-Z Transform
The paper presents a new method to measure motor speed by means of frequency estimation of rotor slot harmonics present in the supply current of squirrel single cage induction motors. The novelty of the method is the use of Chirp-Z Transform as supply current harmonic analysis. The advantages are an improved spectral resolution and accuracy. Moreover a shorter sampling time window is required reducing errors related to not stationary current signal. Experimental results are presented to validate the proposed method and to perform a comparison with FFT based one.
Theoretical and Experimental Comparison of Total Harmonic Distortion Factors for the Evaluation of Harmonic and Interharmonic Pollution of Grid-Connected Photovoltaic Systems
Grid connected photovoltaic systems are increasingly used in electrical distribution systems. However, they inject distorted currents. Therefore special attention must be paid to harmonic and interharmonic measurements. The new edition of IEC 61000-4-7 introduces the concept of harmonic and interharmonic groups, which implies new expressions for Total Harmonic Distortion factors. In the paper a theoretical and experimental comparison is made between the different total harmonic distortion factors in order to show which of the currently defined distortion factors is best-suited to detect harmonic and interharmonic pollution. Experimental tests were carried out first by means of a calibrator …
A chirp-z transform-based synchronizer for power system measurements
In the last few years, increased interest in power and voltage quality has forced international working groups to standardize testing and measurement techniques. IEC 61000-4-30, which defines the characteristics of instrumentation for the measurement of power quality, refers to IEC 61000-4-7 for the evaluation of harmonics and interharmonics. This standard, revised in 2002, requires a synchronous sampling of voltage or current signal, in order to limit errors and to ensure reproducible results even in the presence of nonstationary signals. Therefore, an accurate estimation of the fundamental frequency is required, even in the presence of disturbances. In this paper, an algorithm to detect t…
A self-synchronizing instrument for harmonic sources detection in power systems
The deregulation of energy markets holds out new prospects for contract between customers and utilities, in which the price of energy can depend on voltage quality and load characteristics, as well as on the responsibility for disturbances caused to supply voltage in power systems. In this context, harmonic sources detection is one of the main problems, because of equipment sensibility and the proliferation of loads which absorb non-sinusoidal currents. In this paper the authors present a new instrument based on a time domain method for the detection of harmonic active powers in three-phase systems, which can be usefully applied even in the presence of unbalance or asymmetry. The amplitude …
Disability Management e culture organizzative: Verso la definizione di un modello di orientamento culturale dell’organizzazione verso la disabilità a lavoro
L’ultimo decennio ha visto indubbiamente aumentare la sensibilità delle aziende italiane nei confronti del Disability Management, inteso come un approccio strategico finalizzato alla valorizzazione e all’empowering dei lavoratori con disabilità. A fronte di questa crescente attestazione d’interesse, tradotta peraltro in sempre più numerose iniziative gestionali mirate, si riscontra tuttavia ad oggi una carenza di modelli che consentano di valutare se, e quanto, la cultura e i valori di un’organizzazione siano congruenti con l’implementazione e lo sviluppo di pratiche di gestione delle differenze legate alla disabilità, pienamente in linea con una logica di valorizzazione delle diverse abili…
Disability management in azienda: Il valore dei limiti
L'articolo mira a definire il Diversity Management Disability in termini di cultura organizzativa, partendo da quello che è il senso del “Limite” e il suo superamento e spiegando in cosa consiste il Disability Management e il suo utilizzo.
An induction motor speed measurement method based on current harmonic analysis with the Chirp-Z Transform
This paper presents a new method to measure motor speed by means of frequency estimation of rotor slot spectral components in the supply current of squirrel single-cage induction motors. The novelty of the method consists in the harmonic analysis of the supply current by means of the chirp-Z transform (CZT). The advantages are improved accuracy due to better spectral resolution and resolvability. Moreover, a shorter observation window is required, thus reducing errors related to nonstationary current signals. The experimental results are presented to validate the proposed method and to make a comparison with a similar method based on the fast Fourier transform (FFT).
A fully-automated procedure for measuring the electrical parameters of an induction motor drive with rotor at standstill
The paper presents an automatic procedure to measure at standstill the electrical parameters of an induction motor fed by a PWM voltage source inverter. The proposed procedure executes automatically three tests using only the available PWM inverter control technique to obtain the required motor supply voltages. It allows the measurement of all the T-form circuit electrical parameters starting from the nameplate data as data-entry. It uses only a current sensor and no voltage sensor and process on line the collected data samples with a fast and easy to implement recursive least squares algorithm. Effectiveness of the automated procedure has been proved both by simulation and experimental tes…