0000000001120306
AUTHOR
A. Ali
Recent progress with microchannel-plate PMTs
Abstract Microchannel-plate (MCP) PMTs were identified as the only suitable photon sensors for the two DIRC detectors of the PANDA experiment at FAIR. As the long-standing aging problem of MCP-PMTs was recently overcome by coating the MCP pores with an atomic layer deposition (ALD) technique, further improved 2 ″ MCP-PMTs were investigated. The best PHOTONIS device has reached a lifetime of > 20 C/cm2 integrated anode charge without any sign of aging. Also the newly developed 2 ″ MCP-PMTs of Hamamatsu are maturing and are usable in high rate environments. The status of our long-term lifetime measurements and the performance parameters of the currently most advanced ALD-coated MCP-PMTs from …
Latest improvements of microchannel-plate PMTS
Abstract The DIRC detectors of the PANDA experiment at FAIR will use multi-anode MCP-PMTs as photon sensors. After long and extensive R&D work the performance parameters of the recent 2” MCP-PMT models are converging towards the required values. The lifetime of most ALD-coated MCP-PMTs is well surpassing the DIRC requirements with the best tube currently reaching > 22 C/cm2 integrated anode charge without aging. The performance of the most advanced MCP-PMTs from PHOTONIS and Hamamatsu fulfill basically all requirements with a highlight being the high detective quantum efficiency (DQE) of almost 30% for the PHOTONIS 9002108. The improvements of the latest MCP-PMT models compared to former tu…
The PANDA DIRC Detectors at FAIR
The PANDA detector at the international accelerator Facility for Antiproton and Ion Research in Europe (FAIR) addresses fundamental questions of hadron physics. An excellent hadronic particle identification (PID) will be accomplished by two DIRC (Detection of Internally Reflected Cherenkov light) counters in the target spectrometer. The design for the barrel region covering polar angles between 22 deg. to 140 deg. is based on the successful BABAR DIRC with several key improvements, such as fast photon timing and a compact imaging region. The novel Endcap Disc DIRC will cover the smaller forward angles between 5 deg. (10 deg.) to 22 deg. in the vertical (horizontal) direction. Both DIRC coun…
SARS-CoV-2 vaccination modelling for safe surgery to save lives: data from an international prospective cohort study
Abstract Background Preoperative SARS-CoV-2 vaccination could support safer elective surgery. Vaccine numbers are limited so this study aimed to inform their prioritization by modelling. Methods The primary outcome was the number needed to vaccinate (NNV) to prevent one COVID-19-related death in 1 year. NNVs were based on postoperative SARS-CoV-2 rates and mortality in an international cohort study (surgical patients), and community SARS-CoV-2 incidence and case fatality data (general population). NNV estimates were stratified by age (18–49, 50–69, 70 or more years) and type of surgery. Best- and worst-case scenarios were used to describe uncertainty. Results NNVs were more favourable in su…
The PANDA Endcap Disc DIRC
Journal of Instrumentation 13(02), C02002 - C02002 (2018). doi:10.1088/1748-0221/13/02/C02002
The Barrel DIRC detector of PANDA
The PANDA experiment is one of the four large experiments being built at FAIR in Darmstadt. It will use a cooled antiproton beam on a fixed target within the momentum range of 1.5 to 15 GeV/c to address questions of strong QCD, where the coupling constant $\alpha_s \gtrsim 0.3$. The luminosity of up to $2 \cdot 10^{32} cm^{-2}s^{-1}$ and the momentum resolution of the antiproton beam down to \mbox{$\Delta$p/p = 4$\cdot10^{-5}$} allows for high precision spectroscopy, especially for rare reaction processes. Above the production threshold for open charm mesons the production of kaons plays an important role for identifying the reaction. The DIRC principle allows for a compact particle identif…
Simultaneous measurement of the muon neutrino charged-current cross section on oxygen and carbon without pions in the final state at T2K
Authors: K. Abe,56 N. Akhlaq,45 R. Akutsu,57 A. Ali,32 C. Alt,11 C. Andreopoulos,54,34 L. Anthony,21 M. Antonova,19 S. Aoki,31 A. Ariga,2 T. Arihara,59 Y. Asada,69 Y. Ashida,32 E. T. Atkin,21 Y. Awataguchi,59 S. Ban,32 M. Barbi,46 G. J. Barker,66 G. Barr,42 D. Barrow,42 M. Batkiewicz-Kwasniak,15 A. Beloshapkin,26 F. Bench,34 V. Berardi,22 L. Berns,58 S. Bhadra,70 S. Bienstock,53 S. Bolognesi,6 T. Bonus,68 B. Bourguille,18 S. B. Boyd,66 A. Bravar,13 D. Bravo Berguño,1 C. Bronner,56 S. Bron,13 A. Bubak,51 M. Buizza Avanzini ,10 T. Campbell,7 S. Cao,16 S. L. Cartwright,50 M. G. Catanesi,22 A. Cervera,19 D. Cherdack,17 N. Chikuma,55 G. Christodoulou,12 M. Cicerchia,24,† J. Coleman,34 G. Collazu…
The PANDA Barrel DIRC
The PANDA experiment at the international accelerator Facility for Antiproton and Ion Research in Europe (FAIR) near GSI, Darmstadt, Germany will address fundamental questions of hadron physics. Excellent Particle Identification (PID) over a large range of solid angles and particle momenta will be essential to meet the objectives of the rich physics program. Charged PID for the barrel region of the PANDA target spectrometer will be provided by a DIRC (Detection of Internally Reflected Cherenkov light) detector. The Barrel DIRC will cover the polar angle range of 22$^\circ$-140$^\circ$ and cleanly separate charged pions from kaons for momenta between 0.5 GeV/c and 3.5 GeV/c with a separation…
Recent results with lifetime enhanced microchannel-plate photomultipliers
Abstract The favored photon sensors for the DIRC (detection of internally reflected Cherenkov light) detectors at the PANDA (Anti-proton Annihilation at Darmstadt) experiment at FAIR (Facility for anti-proton and ion research) are micro-channel-plate photomultipliers (MCP-PMTs). The main problem until a few years ago was the limited lifetime of the MCP-PMTs caused by a rapid decrease in quantum efficiency (QE) of the photo cathode (PC) with increasing integrated anode charge (IAC). These limitations are overcome by applying an atomic layer deposition (ALD) coating on the MCPs, as recently done by PHOTONIS and Hamamatsu. During the last years’ tests of lifetime enhanced MCP-PMTs were perform…
The PROVENT-C19 registry: A study protocol for international multicenter SIAARTI registry on the use of prone positioning in mechanically ventilated patients with COVID-19 ARDS
Background The worldwide use of prone position (PP) for invasively ventilated patients with COVID-19 is progressively increasing from the first pandemic wave in everyday clinical practice. Among the suggested treatments for the management of ARDS patients, PP was recommended in the Surviving Sepsis Campaign COVID-19 guidelines as an adjuvant therapy for improving ventilation. In patients with severe classical ARDS, some authors reported that early application of prolonged PP sessions significantly decreases 28-day and 90-day mortality. Methods and analysis Since January 2021, the COVID19 Veneto ICU Network research group has developed and implemented nationally and internationally the “PRO…
Gamma Ray Spectra from Thermal Neutron Capture on Gadolinium-155 and Natural Gadolinium
Natural gadolinium is widely used for its excellent thermal neutron capture cross section, because of its two major isotopes: $^{\rm 155}$Gd and $^{\rm 157}$Gd. We measured the $\gamma$-ray spectra produced from the thermal neutron capture on targets comprising a natural gadolinium film and enriched $^{\rm 155}$Gd (in Gd$_{2}$O$_{3}$ powder) in the energy range from 0.11 MeV to 8.0 MeV, using the ANNRI germanium spectrometer at MLF, J-PARC. The freshly analysed data of the $^{\rm 155}$Gd(n, $\gamma$) reaction are used to improve our previously developed model (ANNRI-Gd model) for the $^{\rm 157}$Gd(n, $\gamma$) reaction, and its performance confirmed with the independent data from the $^{\r…
Gamma Ray Spectrum from Thermal Neutron Capture on Gadolinium-157
International audience; We have measured the |$\gamma$|-ray energy spectrum from the thermal neutron capture, |${}^{157}$|Gd|$(n,\gamma)$|, on an enriched |$^{157}$|Gd target (Gd|$_{2}$|O|$_{3}$|) in the energy range from 0.11 MeV up to about 8 MeV. The target was placed inside the germanium spectrometer of the ANNRI detector at J-PARC and exposed to a neutron beam from the Japan Spallation Neutron Source (JSNS). Radioactive sources (|$^{60}$|Co, |$^{137}$|Cs, and |$^{152}$|Eu) and the |$^{35}$|Cl(|$n$|,|$\gamma$|) reaction were used to determine the spectrometer‘s detection efficiency for |$\gamma$| rays at energies from 0.3 to 8.5 MeV. Using a Geant4-based Monte Carlo simulation of …
Lifetime of MCP-PMTs and other performance features
The ANDA experiment at FAIR will use DIRC detectors for the separation of hadrons. The compactness of the ANDA detector requires the image planes of these detectors to be placed inside the magnetic field of the solenoid. Due to this and other boundary conditions MCP-PMTs were identified as the only suitable photon sensors. Until recently the major obstacle for an application of MCP-PMTs in high rate experiments like ANDA were serious aging problems which led to damage at the photo-cathode and a fast declining quantum efficiency as the integrated anode charge (IAC) increased. With new countermeasures against the aging, in particular due to the application of an atomic layer deposition (ALD) …
The Effect of Polyacrylic Acid and Sodium Trimetaphosphate on Dentin Hybrid Layer Remineralization : an In Vitro Study
Adhesive monomers are not able to fully encapsulate collagen fibrils in hybrid layer leaving them vulnerable to time-dependent hydrolytic degradation. The current in vitro study was designed for investigation of the remineralization of the resin-dentin hy
The CKM Matrix and the Unitarity Triangle
This report contains the results of the Workshop on the CKM Unitarity Triangle, held at CERN on 13-16 February 2002 to study the determination of the CKM matrix from the available data of K, D, and B physics. This is a coherent document with chapters covering the determination of CKM elements from tree level decays and K and B meson mixing and the global fits of the unitarity triangle parameters. The impact of future measurements is also discussed.
The PANDA DIRC detectors
Abstract The PANDA experiment at the future Facility for Antiproton and Ion Research (FAIR) will address fundamental questions of hadron physics with unprecedented precision. To reach this goal excellent Particle Identification (PID) is essential over a large range of particle momenta and solid angles. Most of the phase space will be covered by two innovative DIRC (Detection of Internally Reflected Cherenkov light) detectors. The Endcap Disc DIRC and Barrel DIRC will cover the polar angle range from 5 to 22°and 22 to 140°, respectively. Both detectors rely on high precision optical components, lifetime-enhanced Microchannel Plate PMTs (MCP-PMTs), and fast readout electronics.
Particle identification algorithms for the PANDA Barrel DIRC
The International Conference Instrumentation for Colliding Beam Physics , INSTR2020, Novosibirsk, Russia, 24 Feb 2020 - 28 Feb 2020; Journal of Instrumentation 15(09), C09057 (2020). doi:10.1088/1748-0221/15/09/C09057
Endcap Disc DIRC for PANDA at FAIR
The Endcap Disc DIRC (EDD) has been developed to provide an excellent particle identification in the future PANDA experiment by separating pions and kaons up to a momentum of 4 GeV/c with a separation power of 3 s.d.. The detector is placed in the forward endcap of the PANDA target spectrometer. It consists of a fused silica plate and focusing elements placed at the outer rim, which focus the Cherenkov light on the photo cathodes of the attached MCP-PMTs. A compact and fast readout of the signals is realized with special ASICs. The performance has been studied and validated with different prototype setups in various testbeam facilities.