Time course of cerebrovascular autoregulation during extreme Trendelenburg position for robotic-assisted prostatic surgery
Trendelenburg positioning in combination with pneumoperitoneum during robotic-assisted prostatic surgery possibly impairs cerebrovascular autoregulation. If cerebrovascular autoregulation is disturbed, arterial hypertension might induce cerebral hyperaemia and brain oedema, while low arterial blood pressure can induce cerebral ischaemia. The time course of cerebrovascular autoregulation was investigated during use of the Trendelenburg position and a pneumoperitoneum for robotic-assisted prostatic surgery using transcranial Doppler ultrasound. Cerebral blood flow velocity was correlated with arterial blood pressure and the autoregulation index (Mx) was calculated. In 23 male patients, Mx was…