Misfit evaluation of dental implant-supported metal frameworks manufactured with different techniques: Photoelastic and strain gauge measurements
This study aims to compare in-vitro the fitting accuracy of implant-supported metal frameworks used for full-arch orthodontic restoration. The hypotheses tested were as follows: (1) for a fixed implant morphology, strains developed within the framework depend on how the framework had been fabricated and (2) stresses transferred to the implant–bone interface are related to the amount of framework misfit. Metal frameworks were fabricated using four different manufacturing techniques: conventional lost-wax casting, resin cement luting, electrospark erosion, and computer-aided design/computer-aided manufacturing milling. Each framework was instrumented with three strain gauges to measure strai…