0000000001170074

AUTHOR

Melanie Ludwig

showing 2 related works from this author

Measurement, Prediction, and Control of Individual Heart Rate Responses to Exercise-Basics and Options for Wearable Devices.

2018

The use of wearable devices or "wearables" in the physical activity domain has been increasing in the last years. These devices are used as training tools providing the user with detailed information about individual physiological responses and feedback to the physical training process. Advantages in sensor technology, miniaturization, energy consumption and processing power increased the usability of these wearables. Furthermore, available sensor technologies must be reliable, valid, and usable. Considering the variety of the existing sensors not all of them are suitable to be integrated in wearables. The application and development of wearables has to consider the characteristics of the p…

Computer scienceProcess (engineering)Physiologyheart rate control0206 medical engineeringControl (management)Wearable computerphenomenological approaches02 engineering and technologyReviewUSablelcsh:Physiology03 medical and health sciences0302 clinical medicineheart rate predictionHuman–computer interactionPhysiology (medical)training monitoringWearable technologyheart rate modelinglcsh:QP1-981business.industrywearable sensorsUsability030229 sport sciencesEnergy consumption020601 biomedical engineeringVariety (cybernetics)load controlddc:004businessFrontiers in physiology
researchProduct

Including the Past: Performance Modeling Using a Preload Concept by Means of the Fitness-Fatigue Model

2019

Abstract In mathematical modeling by means of performance models, the Fitness-Fatigue Model (FF-Model) is a common approach in sport and exercise science to study the training performance relationship. The FF-Model uses an initial basic level of performance and two antagonistic terms (for fitness and fatigue). By model calibration, parameters are adapted to the subject’s individual physical response to training load. Although the simulation of the recorded training data in most cases shows useful results when the model is calibrated and all parameters are adjusted, this method has two major difficulties. First, a fitted value as basic performance will usually be too high. Second, without mo…

03 medical and health sciencesPreload0302 clinical medicineGeneral Computer ScienceComputer science05 social sciencesBiomedical Engineering050301 education030229 sport sciences0503 educationddc:006Simulation
researchProduct