0000000001233911

AUTHOR

Junbo Ge

Coronary Artery Shape and Flow Changes Induced by Myocardial Bridging.

Changes in coronary shape and blood flow induced by myocardial bridging were analyzed in a 56-year-old patient with symptoms of unstable angina after the exclusion of other heart disease. Coronary angiography demonstrated a 1.8-cm long myocardial bridge in the middle part of the left anterior descending coronary artery. In systole, an eccentric compression of the artery occurred, resulting in a stenosis that occupied 86% of the diameter and 96% of the area. Intraluminal ultrasound was performed with a 20-MHz transducer in a 4.8-Fr catheter sheath (Boston Scientific Corp.) connected to an ultrasound console (Diasonics Inc.). A side saddle catheter was introduced into the left anterior descen…

research product

Guiding Principles for Chronic Total Occlusion Percutaneous Coronary Intervention. A Global Expert Consensus Document

© American Heart Association, Inc.

research product

Global Chronic Total Occlusion Crossing Algorithm

© 2021 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation. This is an open access article under the CC By-NC-ND License (http://creativecommons.org/licenses/by-nc-nd/4)

research product

Acute coronary artery closure following intracoronary ultrasound examination

Two patients undergoing intracoronary ultrasound examination were complicated by acute coronary artery closure. One of the complications was thought to be caused by intimal dissection and thrombus formation and the other was thought to be caused by intimal dissection and subsequent embolization. The complications were successfully managed conservatively in both cases. © 1995 Wiley-Liss, Inc.

research product

Enhanced detection of contrast regions in echocardiograms by adaptive quantization

The statistics of ultrasound echo images are governed by Rayleigh statistics. The authors derive some experimentally verifiable predictions of this theory, compare them with experimental results obtained from echocardiographic images, and derive a new color coding scheme, (adaptive quantization) that is adapted to the signal-dependent noise predicted by theory. This results in some technical advantages and in an improved discrimination of regions of the echo image that are enhanced by echo contrast material. >

research product

Effects of alirocumab on types of myocardial infarction : insights from the ODYSSEY OUTCOMES trial

Gislason, Gunnar H/0000-0002-0548-402X; Malynovsky, Yaroslav V/0000-0002-9118-1104; Bhatt, Deepak L./0000-0002-1278-6245; Nikolaev, Konstantin/0000-0003-4601-6203; Sherwood, Matthew/0000-0002-4305-5883; Chumakova, Galina A/0000-0002-2810-6531; Raffel, Owen C/0000-0001-5470-7050; Leonardi, Sergio/0000-0002-4800-6132; Tse, Hung Fat/0000-0002-9578-7808; Reshetko, Olga/0000-0003-3107-7636; Pereira, Helder/0000-0001-8656-4883; Racca, Vittorio/0000-0002-4465-3789; Podoleanu, Cristian/0000-0001-9987-2519; Ersanli, Murat/0000-0003-1847-3087; Muenzel, Thomas/0000-0001-5503-4150; Sandhu, Manjinder/0000-0003-2538-2079; Taskinen, Marja-Riitta/0000-0002-6229-3588; bastos, jose/0000-0002-9526-3123; Manak…

research product

High-Frequency Rotational Angioplasty

In 19 patients with significant coronary artery disease, PTCR was used instead of PTCA. The PTCR was successful in all patients, but in nine patients additional PTCA was successfully performed. Coronary luminal narrowing could be reduced from 78 ± 19% to 32 ± 14% after rotablation and by combined treatment to 21 ± 14%. Only in one patient did coronary dissection occur; the patient was sent to surgery and had an uneventful outcome. No vessel perforation was observed. In one patient peripheral diagonal branch occlusion occurred. All vessels were open according to 24-control coronary angiography. Restenosis (>70% stenosis) occurred in 4/15 patients controlled after 6 months, mainly in those wi…

research product

Interventional cardiology: Differences in the morphology of unstable and stable coronary lesions and their impact on the mechanisms of angioplasty. An in vivo study with intravascular ultrasound

The aim of this study was to compare the morphology of stable and unstable coronary lesions using intravascular ultrasound in patients undergoing coronary balloon angioplasty and to determine whether lesion morphology had any influence on the mechanism of balloon angioplasty. Thirty three (15 stable and 18 unstable) patients undergoing single lesion percutaneous transluminal coronary angioplasty were studied with intravascular ultrasound before and after intervention. All examinations, recorded on S-VHS video tape, were studied off-line and matched sites from the point of minimum lumen area after the procedure and the corresponding site prior to intervention were compared. The morphology of…

research product

Global Chronic Total Occlusion Crossing Algorithm: JACC State-of-the-Art Review

© 2021 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation. This is an open access article under the CC-BY-NC-ND license.

research product

Spontaneous plaque rupture visualized by intravascular ultrasound.

An intravascular ultrasound examination was performed in order to evaluate an angiographically complicated lesion. Intravascular ultrasound was able to demonstrate spontaneous plaque rupture in a patient with recent acute subendocardial infarction. The inconclusive angiographic appearance was clarified by the intravascular examination and led us to conclude that the myocardial infarction was due to plaque rupture with subsequent thrombotic occlusion, which had spontaneously resolved by the time of the study.

research product

Intravascular ultrasound imaging of arterial wall architecture.

Intravascular ultrasound (IVUS) is a promising new technique for assessing vascular morphology and structure. Controversy exists whether the three-layer appearance of the arterial wall correctly reflects the histologic structures of the intima, media, and adventitia. We performed an experimental study to clarify the three-layer appearance. The vessel wall architecture was analyzed by IVUS on eight different kinds of plastic cylinders, 24 normal blood vessels from pigs, and 59 human arterial segments. A distinct three-layer appearance was observed on all the plastic cylinders when the ultrasound beam was perpendicular to the wall. A three-layer appearance was also seen in the arterial wall, …

research product