0000000001235073

AUTHOR

Manuel López-nicolás

0000-0001-9735-550x

showing 2 related works from this author

Effect of different ergonomic supports on muscle activity of dentists during posterior composite restoration

2019

BackgroundThe aim of this study was to evaluate the effect of different ergonomic supports on the muscle activity of two trunk muscles while a group of dentists performed a common dental procedure on a phantom head, divided into three tasks.MethodsA one-way repeated measures study (ANOVA) was conducted on a group of 36 dentists. The middle trapezius and lumbar erector spinae muscles were measured with and without the use of different ergonomic supports (ergonomic stool, magnification lenses and both) using a portable surface electromyography (sEMG) device. Intraclass correlation coefficients (ICCs) and the absolute standard error of measurement (SEM) were used to establish the reliability o…

Anatomy and PhysiologyIntraclass correlationDentistslcsh:MedicineMagnificationElectromyographyMusculoskeletal disordersGeneral Biochemistry Genetics and Molecular Biology03 medical and health sciences0302 clinical medicineLumbarErector spinae musclesMedicine0501 psychology and cognitive sciencesMuscle activity050107 human factorsOrthodonticsmedicine.diagnostic_testElectromyographyPhysical therapy modalitiesbusiness.industryGeneral Neurosciencelcsh:R05 social sciencesRepeated measures design030206 dentistryGeneral MedicineKinesiologyOrthopedicsDentistryPublic HealthErgonomicsGeneral Agricultural and Biological SciencesTrunk musclebusinessPeerJ
researchProduct

Validity and Reliability of a New Optoelectronic System for Measuring Active Range of Motion of Upper Limb Joints in Asymptomatic and Symptomatic Sub…

2019

The aim of this study was to evaluate the validity of the Veloflex infrared dynamic angle-meter (Veloflex-IDA) and the intra- and inter-rater reliability when measuring the ranges of motion (ROMs) of the upper limb joints. Thirty-five healthy and 20 symptomatic participants were evaluated. Twelve upper limb movements were measured in two sessions with the Veloflex-IDA, which is a device composed of a camera that tracks the trajectory of retro-reflective markers. In addition, a goniometer was used in the first session to evaluate concurrent validity. Validity and agreement were evaluated by Pearson correlation coefficient (r) and Bland&ndash

educationConcurrent validityupper limb jointslcsh:MedicineValidityArticlerange of motion03 medical and health sciencessymbols.namesake0302 clinical medicineMedicineReliability (statistics)optoelectronic deviceOrthodontics030222 orthopedicsbusiness.industrylcsh:R030229 sport sciencesGeneral MedicinePearson product-moment correlation coefficientbiomedical technologyStandard errormedicine.anatomical_structureGoniometersymbolsUpper limbRange of motionbusinessJournal of Clinical Medicine
researchProduct