Developments on the 1.4 MeV/u Pulsed Gas Stripper Cell
The GSI UNILAC in combination with SIS18 will serve as a high-current, heavy-ion injector for the FAIR facility. It must meet high demands in terms of beam brilliance at a low duty factor. As part of an UNILAC upgrade program dedicated to FAIR, a new pulsed gas stripper cell was developed, aiming for increased beam intensities inside the post-stripper. The pulsed gas injection is synchronized with the beam pulse timing, enabling a highly-demanded, increased gas density. First tests using uranium beams on a hydrogen target showed a 60%-increased stripping efficiency into the desired 28+ charge state. In 2015, the setup was improved to be able to deliver increased target thicknesses and enhan…