0000000001296182
AUTHOR
Federica De Marines
Occurrence of Microplastics in Waste Sludge of Wastewater Treatment Plants: Comparison between Membrane Bioreactor (MBR) and Conventional Activated Sludge (CAS) Technologies.
In this study, the presence of microplastics in the sludge of three wastewater treatment plants (WWTPs) was examined. The investigated WWTPs operated based on a conventional activated sludge (CAS) process, with (W1) or without (W2) primary clarification, and a membrane bioreactor process (MBR) (W3). The microplastics (MPs) concentration in the samples of W3 was approximately 81.1 ± 4.2 × 103 particles/kg dry sludge, whereas MPs concentrations in W1 and W2 were 46.0 ± 14.8 × 103 particles/kg dry sludge and 36.0 ± 5.2 × 103 particles/kg dry sludge, respectively. Moreover, MPs mainly consisted of fragments (66–68%) in the CAS plants, whereas the fra…
Influence of the Oxic-Settling-Anaerobic (OSA) Process on Methane Production by Anaerobic Digestion of Sewage Sludge
The present study evaluated different sludge-reduction mechanisms in the oxic-settling-anaerobic (OSA) process in terms of their effects on methane productivity by anaerobic digestion of sewage sludge. Two different layouts were investigated for the sludge return from an anaerobic side-stream reactor (ASSR) to the anoxic (scheme A) or the aerobic (scheme B) reactor of a pre-denitrification plant. Biochemical methane-potential (BMP) assays performed on the excess sludge revealed that scheme A promoted an overall increase of methane production in the OSA (20 mLCH4 gVSS−1d−1, +19%), although compared with a control CAS plant a significant decrease in the excess sludge production (3…
Insights on mechanisms of excess sludge minimization in an oxic-settling-anaerobic process under different operating conditions and plant configurations
In the present research, insights about the mechanisms of excess sludge minimization occurring in an oxic-settling-anaerobic (OSA) were provided. The investigation involved two systems operating in parallel. In particular, a conventional activated sludge (CAS) system as control and a system implementing the OSA process both having a pre-denitrification scheme were considered. Five periods (P1-P5) were studied, during which several operating conditions and configurations were tested. Specifically, the hydraulic retention time (HRT) in the anaerobic reactor of the OSA system (P1 8 h, P2-P3 12 h, P4 8 h, P5 12 h) and the return sludge from the anaerobic to the anoxic (scheme A) (P1-P2) or aero…