A new method for detemining the Angstrom turbidity coefficient from broad-band filter measurements.

María Pilar Utrillas EstebanRoberto Pedrós EstebanJosé Antonio Martínez LozanoFernando Tena Sangüesa

subject

Radiació solarTermodinàmicaPhysics::Optics

description

In this work, a new method for determining Ångström turbidity coefficients is presented. This method is based on broadband filter irradiance measurements. By combining measurements obtained with different filters it is possible to obtain a single value of the turbidity coefficient representative of the whole measurement range of the pyrheliometer. The results provided by this new method are compared with the original Ångström method and turbidity coefficient values derived by spectroradiometric measurements. The results reproduce the actual values, as measured by a spectroradiometer, better than the previous best correlation did, thus demonstrating the advantage of analyzing the optical thickness from bands covering the whole spectral range.

10.1175/1520-0450(2000)039http://hdl.handle.net/10550/45023