6533b7d6fe1ef96bd12666c1
RESEARCH PRODUCT
The impact of irreversible image data compression on post-processing algorithms in computed tomography
Jan BorggrefeDaniel Pinto Dos SantosConrad FrieseAline Mähringer-kunzPeter MildenbergerRoman Kloecknersubject
Image processing030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineGeneral RadiologyImage Processing Computer-AssistedHumansMedicineRadiology Nuclear Medicine and imagingLungCardiac imagingRetrospective Studiesbusiness.industryReproducibility of ResultsExtremitiesHeartVolume renderingData CompressionUncompressed videoLiverTomographyTomography X-Ray ComputedCardiology and Cardiovascular MedicinebusinessAlgorithmVolume (compression)Image compressionData compressiondescription
PURPOSE: We aimed to evaluate the influence of irreversible image compression at varying levels on image post-processing algorithms (3D volume rendering of angiographs, computer-assisted detection of lung nodules, segmentation and volumetry of liver lesions, and automated evaluation of functional cardiac imaging) in computed tomography (CT). METHODS: Uncompressed CT image data (30 angiographs of the lower limbs, 38 lung exams, 20 liver exams and 30 cardiac exams) were anonymized and subsequently compressed using the JPEG2000 algorithm with compression ratios of 8:1, 10:1, and 15:1. Volume renderings of CT angiographies obtained from compressed and uncompressed data were compared using objective and subjective measures. Computer-assisted detection of lung nodules was performed on compressed and uncompressed image data and compared with respect to diagnostic performance. Segmentation and volumetry of liver lesions as well as measurement of ejection fraction on cardiac studies was performed on compressed and uncompressed datasets; differences in measurements were analyzed. RESULTS: No differences could be detected for the 3D volume renderings and no statistically significant differences in performance were found for the computer-assisted detection algorithm. Measurements in volumetry of liver lesions and functional cardiac imaging showed good to excellent reliability. CONCLUSION: Irreversible image compression within the limits proposed by the European Society of Radiology has no significant influence on commonly used image post-processing algorithms in CT.
year | journal | country | edition | language |
---|---|---|---|---|
2020-01-02 | Diagnostic and Interventional Radiology |