6533b7d9fe1ef96bd126c1b6

RESEARCH PRODUCT

Analysis of the imaging method for assessment of the smile of laser diode bars.

Luis Martı́-lópezWalter D. FurlanJosé A. Ramos-de-campos

subject

PhysicsLaser diodebusiness.industryMaterials Science (miscellaneous)Optical instrumentMagnificationIndustrial and Manufacturing Engineeringlaw.inventionWavelengthOpticslawDigital image processingNear-field scanning optical microscopeBusiness and International ManagementbusinessRotation (mathematics)Image resolution

description

We study imaging systems designed to assess the smile of laser diode bars (LDBs). The magnification matrix is derived from the required sampling period and the geometries of the LDBs and the charge-coupled device (CCD) array. These image-forming systems present in-plane pure translation invariance, but in the case of anamorphic ones, lack in-plane rotation invariance. It is shown that the smile parameters of the image of the LDB are linked with the smile parameters of the LDB by simple mathematical expressions. The spatial resolution of such optical systems is estimated at approximately 1 microm for a mean wavelength of lambda approximately 800 nm. Our results suggest that, with the current state-of-the-art, the formation of imaging methods for LDB smile assessment can be used to assess smile heightsor = 1 microm.

10.1364/ao.48.004880https://pubmed.ncbi.nlm.nih.gov/19745848