Abstract The metastable pitting of titanium has been studied under potentiostatic control in solutions containing chloride ions. An approach based on the charge integration of current transients was proposed for a quantitative determination of metastable pitting. A pit density (dmpit) was defined as the number of metastable pits per unit area per unit time (cm−2 h−1) with a typical size, instead of a size distribution. The calculated dmpit of titanium at 0.5 VSCE in 0.6 M NaCl was about 1.0 × 103 cm−2 h−1 with a typical radius of 0.12 μm. An exponential potential dependence of dmpit was obtained through the integration approach.
year | journal | country | edition | language |
---|---|---|---|---|
2010-10-01 | Corrosion Science |