6533b7ddfe1ef96bd127369b
RESEARCH PRODUCT
Marginal soft tissue stability around conical abutments inserted with the one abutment-one time protocol after 5 years of prosthetic loading
Canullo LuigiPaolo PesceTronchi MauroFiorellini JosephAmari YoshiyukiPenarrocha DavidLuigi Canullosubject
AdultMaleCuspidmedicine.medical_treatmentPlatform switchingAbutmentGingivaDental Abutmentsconical abutments long-term one-abutment-one-time platform switching soft tissue soft tissue biotypeOsseointegrationCrown (dentistry)03 medical and health sciences0302 clinical medicineDental Implants Single-ToothMaxillaMedicineHumansGeneral DentistryOrthodonticslong-termbusiness.industryplatform switchingDental Implantation EndosseousSoft tissueMean ageDental Implant-Abutment Design030206 dentistryConical surfacesoft tissue biotypeconical abutments030220 oncology & carcinogenesisFemaleImplantDental Prosthesis Implant-SupportedOral Surgeryone-abutment-one-timebusinesssoft tissueFollow-Up Studiesdescription
BACKGROUND Soft tissue stability is crucial to obtain and maintain optimal esthetic results. PURPOSE This study aimed to investigate, over 5 years, the soft tissue response using a conical abutment together with the "one-abutment one-time" (OA-OT) protocol in the restoration of implants inserted in the anterior esthetic area. MATERIAL AND METHODS From January 2011 to January 2012, all consecutive patients requiring an implant n the maxillary area between canines were enrolled. After submerged healing and osseointegration, a definitive abutment with a provisional crown was inserted. After 1 month, the definitive crown was delivered (Tdef). Analog impressions were taken before tooth extraction (T0), at implant insertion Timpl, and Tdef, and at 12 months (T1) and 60 months (T5). Casts were scanned and superimposed using a dedicated software. Differences in vertical height of soft tissue margins between the digitized model casts were calculated and paired sample t test was conducted to compare results. To detect the potential role of biotype, groups (thick vs. thin) were compared by analysis of variance with general linear model. RESULTS Twenty-five patients were enrolled. Three patients dropped out. At the 60-month, 22 patients (12 men and 10 women with mean age of 68.3 ± 11 years) concluded the study follow-up. Horizontal changes demonstrated gain of 1.06 mm at Timpl, 0.94 mm at Tdef, 0.92 mm at T1 and 0.97 mm at T5 compared to T0. Vertical changes demonstrated gain of 0.84 mm at Timpl, 0.11 mm at Tdef, 0.29 mm at T1 and 0.59 mm at T5 compared to T0. The analysis of variance showed a significant better performance of thick biotype in soft tissue horizontal width (P = .022). No statistical differences were noticed for vertical width (P = .111). CONCLUSIONS The use of a conical abutment together with the OA-OT approach allowed longitudinal stable soft tissue dimensions.
year | journal | country | edition | language |
---|---|---|---|---|
2018-10-11 |