PolynomialComputer sciencehigh power applicationsSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciCascaded H-Bridge multilevel inverterselective harmonic mitigationSettore ING-IND/31 - ElettrotecnicaAmplitudeThree-phaseControl theoryHarmonicsWaveformInverterMATLABSettore ING-INF/07 - Misure Elettriche E ElettronichecomputerVoltagecomputer.programming_language

description

Selective harmonics elimination or mitigation strategies are used in all applications where it is necessary to rise the efficiency and reliability of the overall system. This paper presents a simple approach to reduce the low order harmonics amplitude of an asymmetrical staircase voltage waveform for a five-level, three-phase Cascaded H-Bridge Inverter without solving non-linear equations. Through this simple approach, polynomial equations to evaluate the control angels in real-time operations have been found. The effectiveness of the harmonic mitigation method has been tested through the simulation analysis in MatLab/PLECS environment.

https://doi.org/10.1109/melecon48756.2020.9140573