6533b828fe1ef96bd12884b9

RESEARCH PRODUCT

Performance of disc diffusion, MIC gradient tests and Vitek 2 for ceftolozane/tazobactam and ceftazidime/avibactam susceptibility testing of Pseudomonas aeruginosa

Damien FournierKaty JeannotPatrick PlésiatBrice Daragon

subject

0301 basic medicineMicrobiology (medical)TazobactamAvibactam030106 microbiologyCeftazidimeMicrobial Sensitivity Testsmedicine.disease_causeTazobactamCeftazidime03 medical and health scienceschemistry.chemical_compound0302 clinical medicinemedicineHumansPharmacology (medical)Pseudomonas Infections030212 general & internal medicineEtestPharmacologyChromatographyPseudomonas aeruginosaChemistryBroth microdilutionCeftazidime/avibactamAnti-Bacterial AgentsCephalosporinsDrug CombinationsInfectious Diseases[SDV.MP]Life Sciences [q-bio]/Microbiology and ParasitologyPseudomonas aeruginosaCeftolozaneAzabicyclo Compoundsmedicine.drug

description

AbstractObjectivesTo assess performance of disc diffusion, gradient tests and Vitek 2 system to determine the susceptibility of clinical Pseudomonas aeruginosa strains to ceftolozane/tazobactam (C/T) and ceftazidime/avibactam (CZA).MethodsTwo-hundred non-duplicate P. aeruginosa strains isolated by 47 French medical laboratories were selected to cover a wide range of C/T and CZA MICs. Performance of C/T disc (30/10 μg, Bio-Rad), CZA discs (10/4 μg) (Thermo Fisher and Bio-Rad), C/T and CZA gradient tests (Etest, BioMérieux; MIC Test Strip, Liofilchem), and AST-XN12 card of Vitek 2 system (BioMérieux) were compared with a broth microdilution (BMD) method (Thermo Fisher). MIC and disc results were interpreted using current EUCAST breakpoints.ResultsTwenty percent and 17% of strains were resistant to C/T and CZA, respectively. All the methods tested satisfactorily determined the susceptibility of P. aeruginosa to C/T [Category Agreement (CA) ≥95%] except the disc diffusion method. Because of the high rates of Major Errors (MEs) (12.5%), this latter method tends to overestimate the resistance. For CZA, only the gradient tests yielded more than 90% of CA. The Vitek 2 system and disc diffusion misclassified 18.1%, 10.1% (disc Bio-Rad) and 11.9% (disc Thermo Fisher) of susceptible strains, respectively.ConclusionsThe gradient tests (MIC Test Strip and Etest) and Vitek 2 card XN12 performed the best to determine the susceptibility of P. aeruginosa to C/T, whereas gradient tests were an acceptable alternative to BMD to assess CZA susceptibility.

10.1093/jac/dkab236https://hal-univ-fcomte.archives-ouvertes.fr/hal-03483278