Effect of a closed foldable equator ring on capsular bag shrinkage in cataract surgery.
Carolin DumbachH. Burkhard DickSabine KurzFrank KrummenauerNorbert Pfeiffersubject
Malemedicine.medical_specialtymedicine.medical_treatmentEye diseaseLens Capsule CrystallineCapsular tension ringMethylmethacrylateProsthesis ImplantationPostoperative ComplicationsLens Implantation IntraocularOphthalmologyMedicineHumansPolymethyl MethacrylateProspective StudiesIntraoperative ComplicationsCapsulorhexisShrinkageAgedPhacoemulsificationbusiness.industryAxial lengthProstheses and ImplantsCataract surgerymedicine.diseaseSensory SystemsOphthalmologyCapsular bagMethacrylatesSurgeryFemalebusinessdescription
To evaluate the effect of a closed foldable equator ring (CFER) versus a conventional capsular tension ring (CTR) on capsular bag shrinkage.Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany.In this prospective study, 70 eyes of 70 patients were randomized to 2 groups using a 1:1 block scheme. After uneventful cataract surgery, a capsular measuring ring was implanted in all eyes to measure the capsular bag diameter in vivo. In Group 1, a CTR was implanted in the capsular bag. In Group 2, a CFER was inserted. Biometric characteristics such as axial length and the horizontal and vertical corneal radii were measured preoperatively. The capsular bag diameter and capsulorhexis diameter were measured intraoperatively and 2 or 3 days as well as 1 and 3 months postoperatively.There were no statistically significant or clinically relevant between-group differences in covariants such as axial length, vertical and horizontal corneal radii, and capsulorhexis diameter. Eyes with the CTR had slight but statistically significant capsular bag shrinkage from a median of 10.4 to a median of 10.2 mm after 3 months (P.001). Eyes with the CFER also had slight but statistically significant capsular bag shrinkage from a median of 10.3 to a median of 10.2 mm 3 months postoperatively (P = .021). At baseline, the CTR group had a larger capsular bag diameter, but there were no statistically significant differences between the groups at the 3-month follow-up (P = .669).No clinically relevant capsular bag shrinkage was observed after implantation of a CFER or a CTR. The expected capsular bag shrinkage was the same in both groups.
year | journal | country | edition | language |
---|---|---|---|---|
2005-01-17 | Journal of cataract and refractive surgery |